BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

640 related articles for article (PubMed ID: 17655477)

  • 1. Comparison of the hemodynamic and thrombogenic performance of two bileaflet mechanical heart valves using a CFD/FSI model.
    Dumont K; Vierendeels J; Kaminsky R; van Nooten G; Verdonck P; Bluestein D
    J Biomech Eng; 2007 Aug; 129(4):558-65. PubMed ID: 17655477
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation technique for bileaflet mechanical valves.
    Shipkowitz T; Ambrus J; Kurk J; Wickramasinghe K
    J Heart Valve Dis; 2002 Mar; 11(2):275-82. PubMed ID: 12000172
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Predicting ATS Open Pivot heart valve performance with computational fluid dynamics.
    Dumont K; Vierendeels JA; Segers P; Van Nooten GJ; Verdonck PR
    J Heart Valve Dis; 2005 May; 14(3):393-9. PubMed ID: 15974535
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Pressure and flow fields in the hinge region of bileaflet mechanical heart valves.
    Gao ZB; Hosein N; Dai FF; Hwang NH
    J Heart Valve Dis; 1999 Mar; 8(2):197-205. PubMed ID: 10224581
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Computational fluid dynamics study of a protruded-hinge bileaflet mechanical heart valve.
    Wang J; Yao H; Lim CJ; Zhao Y; Yeo TJ; Hwang NH
    J Heart Valve Dis; 2001 Mar; 10(2):254-262; discussion 263. PubMed ID: 11297213
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Numerical simulation of opening process in a bileaflet mechanical heart valve under pulsatile flow condition.
    Shi Y; Zhao Y; Yeo TJ; Hwang NH
    J Heart Valve Dis; 2003 Mar; 12(2):245-55. PubMed ID: 12701798
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Flow-induced platelet activation and damage accumulation in a mechanical heart valve: numerical studies.
    Alemu Y; Bluestein D
    Artif Organs; 2007 Sep; 31(9):677-88. PubMed ID: 17725695
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Numerical simulation of the dynamics of a bileaflet prosthetic heart valve using a fluid-structure interaction approach.
    Nobili M; Morbiducci U; Ponzini R; Del Gaudio C; Balducci A; Grigioni M; Maria Montevecchi F; Redaelli A
    J Biomech; 2008 Aug; 41(11):2539-50. PubMed ID: 18579146
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Small aortic annulus: the hydrodynamic performances of 5 commercially available bileaflet mechanical valves.
    Bottio T; Caprili L; Casarotto D; Gerosa G
    J Thorac Cardiovasc Surg; 2004 Sep; 128(3):457-62. PubMed ID: 15354108
    [TBL] [Abstract][Full Text] [Related]  

  • 10. An in vitro investigation of the retrograde flow fields of two bileaflet mechanical heart valves.
    Ellis JT; Healy TM; Fontaine AA; Weston MW; Jarret CA; Saxena R; Yoganathan AP
    J Heart Valve Dis; 1996 Nov; 5(6):600-6. PubMed ID: 8953437
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Two-dimensional dynamic simulation of platelet activation during mechanical heart valve closure.
    Krishnan S; Udaykumar HS; Marshall JS; Chandran KB
    Ann Biomed Eng; 2006 Oct; 34(10):1519-34. PubMed ID: 17013660
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Blood damage safety of prosthetic heart valves. Shear-induced platelet activation and local flow dynamics: a fluid-structure interaction approach.
    Morbiducci U; Ponzini R; Nobili M; Massai D; Montevecchi FM; Bluestein D; Redaelli A
    J Biomech; 2009 Aug; 42(12):1952-60. PubMed ID: 19524927
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An integrated macro/micro approach to evaluating pivot flow within the Medtronic ADVANTAGE bileaflet mechanical heart valve.
    Shu MC; Gross JM; O'Rourke KK; Yoganathan AP
    J Heart Valve Dis; 2003 Jul; 12(4):503-12. PubMed ID: 12918854
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Transient, three-dimensional flow field simulation through a mechanical, trileaflet heart valve prosthesis.
    Kaufmann TA; Linde T; Cuenca-Navalon E; Schmitz C; Hormes M; Schmitz-Rode T; Steinseifer U
    ASAIO J; 2011; 57(4):278-82. PubMed ID: 21642841
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The new St. Jude Medical regent mechanical heart valve: laboratory measurements of hydrodynamic performance.
    Walker DK; Brendzel AM; Scotten LN
    J Heart Valve Dis; 1999 Nov; 8(6):687-96. PubMed ID: 10616249
    [TBL] [Abstract][Full Text] [Related]  

  • 16. ATS prosthetic valve motion: an in vitro analysis.
    Tayama E; Feng Z; Oda T; Tomoeda H; Hayashida N; Fukunaga S; Umezu M; Aoyagi S
    J Heart Valve Dis; 2000 May; 9(3):408-14. PubMed ID: 10888099
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dynamic impact stress analysis of a bileaflet mechanical heart valve.
    Yuan Q; Xu L; Ngoi BK; Yeo TJ; Hwang NH
    J Heart Valve Dis; 2003 Jan; 12(1):102-9. PubMed ID: 12578344
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Single-center outcome analysis of 1,161 patients with St. Jude medical and ATS open pivot mechanical heart valves.
    Bernet FH; Baykut D; Grize L; Zerkowski HR
    J Heart Valve Dis; 2007 Mar; 16(2):151-8. PubMed ID: 17484464
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Numerical analysis on the hemodynamics and leaflet dynamics in a bileaflet mechanical heart valve using a fluid-structure interaction method.
    Choi CR; Kim CN
    ASAIO J; 2009; 55(5):428-37. PubMed ID: 19730001
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Particle image velocimetry investigation of intravalvular flow fields of a bileaflet mechanical heart valve in a pulsatile flow.
    Subramanian A; Mu H; Kadambi JR; Wernet MP; Brendzel AM; Harasaki H
    J Heart Valve Dis; 2000 Sep; 9(5):721-31. PubMed ID: 11041190
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 32.