These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3932 related articles for article (PubMed ID: 17664579)
1. Treatment plan comparison between helical tomotherapy and MLC-based IMRT using radiobiological measures. Mavroidis P; Ferreira BC; Shi C; Lind BK; Papanikolaou N Phys Med Biol; 2007 Jul; 52(13):3817-36. PubMed ID: 17664579 [TBL] [Abstract][Full Text] [Related]
2. Comparison of the 3D-conformal, helical tomotherapy and multileaf collimators-based intensity modulated radiotherapy modalities using radiobiological measures. Mavroidis P; Costa Ferreira B; Shi C; Lind BK; Papanikolaou N J BUON; 2008; 13(1):75-86. PubMed ID: 18404791 [TBL] [Abstract][Full Text] [Related]
3. Comparison of the helical tomotherapy and MLC-based IMRT radiation modalities in treating brain and cranio-spinal tumors. Mavroidis P; Ferreira BC; Shi C; Delichas MG; Lind BK; Papanikolaou N Technol Cancer Res Treat; 2009 Feb; 8(1):3-14. PubMed ID: 19166237 [TBL] [Abstract][Full Text] [Related]
4. Comparison of IMRT treatment plans between linac and helical tomotherapy based on integral dose and inhomogeneity index. Shi C; Peñagarícano J; Papanikolaou N Med Dosim; 2008; 33(3):215-21. PubMed ID: 18674686 [TBL] [Abstract][Full Text] [Related]
5. Helical tomotherapy for head and neck squamous cell carcinoma: dosimetric comparison with linear accelerator-based step-and-shoot IMRT. Murthy V; Master Z; Gupta T; Ghosh-Laskar S; Budrukkar A; Phurailatpam R; Agarwal J J Cancer Res Ther; 2010; 6(2):194-8. PubMed ID: 20622367 [TBL] [Abstract][Full Text] [Related]
6. Intensity-modulated radiation therapy (IMRT) dosimetry of the head and neck: a comparison of treatment plans using linear accelerator-based IMRT and helical tomotherapy. Sheng K; Molloy JA; Read PW Int J Radiat Oncol Biol Phys; 2006 Jul; 65(3):917-23. PubMed ID: 16751074 [TBL] [Abstract][Full Text] [Related]
7. Significant improvement in normal tissue sparing and target coverage for head and neck cancer by means of helical tomotherapy. Fiorino C; Dell'Oca I; Pierelli A; Broggi S; De Martin E; Di Muzio N; Longobardi B; Fazio F; Calandrino R Radiother Oncol; 2006 Mar; 78(3):276-82. PubMed ID: 16546279 [TBL] [Abstract][Full Text] [Related]
8. Dosimetric comparison between 2-dimensional radiation therapy and intensity modulated radiation therapy in treatment of advanced T-stage nasopharyngeal carcinoma: to treat less or more in the planning organ-at-risk volume of the brainstem and spinal cord. Chau RM; Teo PM; Kam MK; Leung SF; Cheung KY; Chan AT Med Dosim; 2007; 32(4):263-70. PubMed ID: 17980826 [TBL] [Abstract][Full Text] [Related]
9. Dosimetric comparison of helical tomotherapy and linac-IMRT treatment plans for head and neck cancer patients. Zhang X; Penagaricano J; Moros EG; Corry PM; Yan Y; Ratanatharathorn V Med Dosim; 2010; 35(4):264-8. PubMed ID: 19944587 [TBL] [Abstract][Full Text] [Related]
10. Comparing 3DCRT and inversely optimized IMRT planning for head and neck cancer: equivalence between step-and-shoot and sliding window techniques. Longobardi B; De Martin E; Fiorino C; Dell'oca I; Broggi S; Cattaneo GM; Calandrino R Radiother Oncol; 2005 Nov; 77(2):148-56. PubMed ID: 16260056 [TBL] [Abstract][Full Text] [Related]
11. Impact of IMRT and leaf width on stereotactic body radiotherapy of liver and lung lesions. Dvorak P; Georg D; Bogner J; Kroupa B; Dieckmann K; Pötter R Int J Radiat Oncol Biol Phys; 2005 Apr; 61(5):1572-81. PubMed ID: 15817364 [TBL] [Abstract][Full Text] [Related]
12. Volumetric modulated arc therapy (VMAT) vs. serial tomotherapy, step-and-shoot IMRT and 3D-conformal RT for treatment of prostate cancer. Wolff D; Stieler F; Welzel G; Lorenz F; Abo-Madyan Y; Mai S; Herskind C; Polednik M; Steil V; Wenz F; Lohr F Radiother Oncol; 2009 Nov; 93(2):226-33. PubMed ID: 19765846 [TBL] [Abstract][Full Text] [Related]
13. Intensity-modulated radiation therapy dose prescription, recording, and delivery: patterns of variability among institutions and treatment planning systems. Das IJ; Cheng CW; Chopra KL; Mitra RK; Srivastava SP; Glatstein E J Natl Cancer Inst; 2008 Mar; 100(5):300-7. PubMed ID: 18314476 [TBL] [Abstract][Full Text] [Related]
14. Helical tomotherapy versus single-arc intensity-modulated arc therapy: a collaborative dosimetric comparison between two institutions. Rong Y; Tang G; Welsh JS; Mohiuddin MM; Paliwal B; Yu CX Int J Radiat Oncol Biol Phys; 2011 Sep; 81(1):284-96. PubMed ID: 21236598 [TBL] [Abstract][Full Text] [Related]
15. Helical tomotherapy-based STAT RT: Dosimetric evaluation for clinical implementation of a rapid radiation palliation program. McIntosh A; Dunlap N; Sheng K; Geezey C; Turner B; Blackhall L; Weiss G; Lappinen E; Larner JM; Read PW Med Dosim; 2010; 35(4):280-6. PubMed ID: 19944589 [TBL] [Abstract][Full Text] [Related]
16. Comparison of the helical tomotherapy against the multileaf collimator-based intensity-modulated radiotherapy and 3D conformal radiation modalities in lung cancer radiotherapy. Mavroidis P; Shi C; Plataniotis GA; Delichas MG; Ferreira BC; Rodriguez S; Lind BK; Papanikolaou N Br J Radiol; 2011 Feb; 84(998):161-72. PubMed ID: 20858664 [TBL] [Abstract][Full Text] [Related]
17. A dosimetric comparison of non-coplanar IMRT versus Helical Tomotherapy for nasal cavity and paranasal sinus cancer. Sheng K; Molloy JA; Larner JM; Read PW Radiother Oncol; 2007 Feb; 82(2):174-8. PubMed ID: 17275112 [TBL] [Abstract][Full Text] [Related]
18. Simultaneous beam geometry and intensity map optimization in intensity-modulated radiation therapy. Lee EK; Fox T; Crocker I Int J Radiat Oncol Biol Phys; 2006 Jan; 64(1):301-20. PubMed ID: 16289912 [TBL] [Abstract][Full Text] [Related]
19. [Dosimetric evaluation of intensity-modulated tangential beam versus conventional tangential irradiation for breast cancer]. Huang XB; Jiang GL; Chen JY; Chen LF; Hu WG Ai Zheng; 2006 Jul; 25(7):855-60. PubMed ID: 16831277 [TBL] [Abstract][Full Text] [Related]
20. Pelvic nodal dose escalation with prostate hypofractionation using conformal avoidance defined (H-CAD) intensity modulated radiation therapy. Hong TS; Tomé WA; Jaradat H; Raisbeck BM; Ritter MA Acta Oncol; 2006; 45(6):717-27. PubMed ID: 16938815 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]