401 related articles for article (PubMed ID: 17664640)
1. Reproducibility of regional lung ventilation distribution determined by electrical impedance tomography during mechanical ventilation.
Frerichs I; Schmitz G; Pulletz S; Schädler D; Zick G; Scholz J; Weiler N
Physiol Meas; 2007 Jul; 28(7):S261-7. PubMed ID: 17664640
[TBL] [Abstract][Full Text] [Related]
2. Thoracic electrical impedance tomographic measurements during volume controlled ventilation-effects of tidal volume and positive end-expiratory pressure.
Frerichs I; Hahn G; Hellige G
IEEE Trans Med Imaging; 1999 Sep; 18(9):764-73. PubMed ID: 10571381
[TBL] [Abstract][Full Text] [Related]
3. Protective ventilation using electrical impedance tomography.
Luepschen H; Meier T; Grossherr M; Leibecke T; Karsten J; Leonhardt S
Physiol Meas; 2007 Jul; 28(7):S247-60. PubMed ID: 17664639
[TBL] [Abstract][Full Text] [Related]
4. Performance of electrical impedance tomography in detecting regional tidal volumes during one-lung ventilation.
Pulletz S; Elke G; Zick G; Schädler D; Scholz J; Weiler N; Frerichs I
Acta Anaesthesiol Scand; 2008 Sep; 52(8):1131-9. PubMed ID: 18840115
[TBL] [Abstract][Full Text] [Related]
5. Effect of positive end-expiratory-pressure on regional ventilation in patients with acute lung injury evaluated by electrical impedance tomography.
Hinz J; Moerer O; Neumann P; Dudykevych T; Hellige G; Quintel M
Eur J Anaesthesiol; 2005 Nov; 22(11):817-25. PubMed ID: 16225714
[TBL] [Abstract][Full Text] [Related]
6. Assessing effects of PEEP and global expiratory lung volume on regional electrical impedance tomography.
Markhorst DG; Groeneveld AB; Heethaar RM; Zonneveld E; Van Genderingen HR
J Med Eng Technol; 2009; 33(4):281-7. PubMed ID: 19384703
[TBL] [Abstract][Full Text] [Related]
7. End-expiratory lung impedance change enables bedside monitoring of end-expiratory lung volume change.
Hinz J; Hahn G; Neumann P; Sydow M; Mohrenweiser P; Hellige G; Burchardi H
Intensive Care Med; 2003 Jan; 29(1):37-43. PubMed ID: 12528020
[TBL] [Abstract][Full Text] [Related]
8. Bedside Contribution of Electrical Impedance Tomography to Setting Positive End-Expiratory Pressure for Extracorporeal Membrane Oxygenation-treated Patients with Severe Acute Respiratory Distress Syndrome.
Franchineau G; Bréchot N; Lebreton G; Hekimian G; Nieszkowska A; Trouillet JL; Leprince P; Chastre J; Luyt CE; Combes A; Schmidt M
Am J Respir Crit Care Med; 2017 Aug; 196(4):447-457. PubMed ID: 28103448
[TBL] [Abstract][Full Text] [Related]
9. Experimental case report: development of a pneumothorax monitored by electrical impedance tomography.
Preis C; Luepschen H; Leonhardt S; Gommers D
Clin Physiol Funct Imaging; 2009 May; 29(3):159-62. PubMed ID: 19207731
[TBL] [Abstract][Full Text] [Related]
10. Electrical impedance tomography and heterogeneity of pulmonary perfusion and ventilation in porcine acute lung injury.
Fagerberg A; Söndergaard S; Karason S; Aneman A
Acta Anaesthesiol Scand; 2009 Nov; 53(10):1300-9. PubMed ID: 19719814
[TBL] [Abstract][Full Text] [Related]
11. Imbalances in regional lung ventilation: a validation study on electrical impedance tomography.
Victorino JA; Borges JB; Okamoto VN; Matos GF; Tucci MR; Caramez MP; Tanaka H; Sipmann FS; Santos DC; Barbas CS; Carvalho CR; Amato MB
Am J Respir Crit Care Med; 2004 Apr; 169(7):791-800. PubMed ID: 14693669
[TBL] [Abstract][Full Text] [Related]
12. Effects of restricted thoracic movement on the regional distribution of ventilation.
Pulletz S; Elke G; Zick G; Schädler D; Reifferscheid F; Weiler N; Frerichs I
Acta Anaesthesiol Scand; 2010 Jul; 54(6):751-60. PubMed ID: 20397981
[TBL] [Abstract][Full Text] [Related]
13. Effect of PEEP on regional ventilation during laparoscopic surgery monitored by electrical impedance tomography.
Karsten J; Luepschen H; Grossherr M; Bruch HP; Leonhardt S; Gehring H; Meier T
Acta Anaesthesiol Scand; 2011 Aug; 55(7):878-86. PubMed ID: 21658014
[TBL] [Abstract][Full Text] [Related]
14. Monitoring pulmonary perfusion by electrical impedance tomography: an evaluation in a pig model.
Fagerberg A; Stenqvist O; Aneman A
Acta Anaesthesiol Scand; 2009 Feb; 53(2):152-8. PubMed ID: 19175575
[TBL] [Abstract][Full Text] [Related]
15. Gravity-dependent ventilation distribution in rats measured with electrical impedance tomography.
Rooney D; Friese M; Fraser JF; R Dunster K; Schibler A
Physiol Meas; 2009 Oct; 30(10):1075-85. PubMed ID: 19738318
[TBL] [Abstract][Full Text] [Related]
16. Regional ventilation distribution determined by electrical impedance tomography: reproducibility and effects of posture and chest plane.
Reifferscheid F; Elke G; Pulletz S; Gawelczyk B; Lautenschläger I; Steinfath M; Weiler N; Frerichs I
Respirology; 2011 Apr; 16(3):523-31. PubMed ID: 21261780
[TBL] [Abstract][Full Text] [Related]
17. Real-time detection of pneumothorax using electrical impedance tomography.
Costa EL; Chaves CN; Gomes S; Beraldo MA; Volpe MS; Tucci MR; Schettino IA; Bohm SH; Carvalho CR; Tanaka H; Lima RG; Amato MB
Crit Care Med; 2008 Apr; 36(4):1230-8. PubMed ID: 18379250
[TBL] [Abstract][Full Text] [Related]
18. Differences in regional pulmonary pressure-impedance curves before and after lung injury assessed with a novel algorithm.
Grychtol B; Wolf GK; Arnold JH
Physiol Meas; 2009 Jun; 30(6):S137-48. PubMed ID: 19491448
[TBL] [Abstract][Full Text] [Related]
19. Electrical impedance tomography guided ventilation therapy.
Putensen C; Wrigge H; Zinserling J
Curr Opin Crit Care; 2007 Jun; 13(3):344-50. PubMed ID: 17468569
[TBL] [Abstract][Full Text] [Related]
20. Detection of local lung air content by electrical impedance tomography compared with electron beam CT.
Frerichs I; Hinz J; Herrmann P; Weisser G; Hahn G; Dudykevych T; Quintel M; Hellige G
J Appl Physiol (1985); 2002 Aug; 93(2):660-6. PubMed ID: 12133877
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]