These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

187 related articles for article (PubMed ID: 17665878)

  • 1. Design and evaluation of an antiparallel coupled resonator for chemical sensor applications.
    Abe T; Kato H
    Anal Chem; 2007 Sep; 79(17):6804-6. PubMed ID: 17665878
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Different experimental results for the influence of immersion angle on the resonant frequency of a quartz crystal microbalance in a liquid phase: with a comment.
    Shen D; Kang Q; Li X; Cai H; Wang Y
    Anal Chim Acta; 2007 Jun; 593(2):188-95. PubMed ID: 17543606
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Acoustic wave flow sensor using quartz thickness shear mode resonator.
    Qin L; Zeng Z; Cheng H; Wang QM
    IEEE Trans Ultrason Ferroelectr Freq Control; 2009 Sep; 56(9):1945-54. PubMed ID: 19811997
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Multichannel monolithic quartz crystal microbalance gas sensor array.
    Jin X; Huang Y; Mason A; Zeng X
    Anal Chem; 2009 Jan; 81(2):595-603. PubMed ID: 19090744
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A lateral-field-excited LiTaO3 high-frequency bulk acoustic wave sensor.
    McCann DF; McGann JM; Parks JM; Frankel DJ; da Cunha MP; Vetelino JF
    IEEE Trans Ultrason Ferroelectr Freq Control; 2009 Apr; 56(4):779-87. PubMed ID: 19406706
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Single-scan measurement of conductance of a quartz crystal microbalance array coupled with resonant markers for biosensing in liquid phase.
    Hsiao HY; Chen RL; Cheng TJ
    Rev Sci Instrum; 2009 Apr; 80(4):044301. PubMed ID: 19405677
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Characteristics of the series resonant-frequency shift of a quartz crystal microbalance in electrolyte solutions.
    Yoshimoto M; Tokimura S; Kurosawa S
    Analyst; 2006 Oct; 131(10):1175-82. PubMed ID: 17003867
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Selective histamine piezoelectric chemosensor using a recognition film of the molecularly imprinted polymer of bis(bithiophene) derivatives.
    Pietrzyk A; Suriyanarayanan S; Kutner W; Chitta R; D'Souza F
    Anal Chem; 2009 Apr; 81(7):2633-43. PubMed ID: 19278237
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Monitoring cell adhesion processes on bioactive polymers with the quartz crystal resonator technique.
    Le Guillou-Buffello D; Hélary G; Gindre M; Pavon-Djavid G; Laugier P; Migonney V
    Biomaterials; 2005 Jul; 26(19):4197-205. PubMed ID: 15664647
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Quartz crystal microbalance based on torsional piezoelectric resonators.
    Bücking W; Du B; Turshatov A; König AM; Reviakine I; Bode B; Johannsmann D
    Rev Sci Instrum; 2007 Jul; 78(7):074903. PubMed ID: 17672786
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The determination of electrical parameters of quartz crystal resonators with the consideration of dissipation.
    Wang J; Zhao W; Du J
    Ultrasonics; 2006 Dec; 44 Suppl 1():e869-73. PubMed ID: 16843512
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Signal amplification with multilayer arrangements on chemical quartz-crystal-resonator sensors.
    Lucklum R; Behling C; Hauptmann P
    IEEE Trans Ultrason Ferroelectr Freq Control; 2000; 47(5):1246-52. PubMed ID: 18238667
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Isolated electrodeless high-frequency quartz crystal microbalance for immunosensors.
    Ogi H; Motoshisa K; Matsumoto T; Hatanaka K; Hirao M
    Anal Chem; 2006 Oct; 78(19):6903-9. PubMed ID: 17007513
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The quartz crystal microbalance as a novel means to study cell-substrate interactions in situ.
    Wegener J; Janshoff A; Steinem C
    Cell Biochem Biophys; 2001; 34(1):121-51. PubMed ID: 11394439
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Viscosity sensor utilizing a piezoelectric thickness shear sandwich resonator.
    Thalhammer R; Braun S; Devcic-Kuhar B; Groschl M; Trampler F; Benes E; Nowotny H; Kostal P
    IEEE Trans Ultrason Ferroelectr Freq Control; 1998; 45(5):1331-40. PubMed ID: 18244295
    [TBL] [Abstract][Full Text] [Related]  

  • 16. On-line monitoring of the viscosity in dextran fermentation using piezoelectric quartz crystal.
    Endo H; Sode K; Karube I; Muramatsu H
    Biotechnol Bioeng; 1990 Sep; 36(6):636-41. PubMed ID: 18595123
    [TBL] [Abstract][Full Text] [Related]  

  • 17. On the applicability of high frequency acoustic shear mode biosensing in view of thickness limitations set by the film resonance.
    Wingqvist G; Anderson H; Lennartsson C; Weissbach T; Yantchev V; Spetz AL
    Biosens Bioelectron; 2009 Jul; 24(11):3387-90. PubMed ID: 19447595
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Measurements of fast fluctuations of viscoelastic properties with the quartz crystal microbalance.
    Pax M; Rieger J; Eibl RH; Thielemann C; Johannsmann D
    Analyst; 2005 Nov; 130(11):1474-7. PubMed ID: 16222366
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Non-gravimetric contributions to QCR sensor response.
    Lucklum R
    Analyst; 2005 Nov; 130(11):1465-73. PubMed ID: 16222365
    [TBL] [Abstract][Full Text] [Related]  

  • 20. QCM operating in threshold mode as a gas sensor.
    Dultsev FN; Kolosovsky EA
    Langmuir; 2009 Oct; 25(20):12195-200. PubMed ID: 19634877
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.