These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

197 related articles for article (PubMed ID: 17669888)

  • 21. [Preservation by pulsatile perfusion machine: the initial experience].
    Suárez Novo JF; Riera Canals L; Franco Miranda E; Colom Feixas S; Serrallach Mila N; Grinyo Boira JM
    Actas Urol Esp; 1999; 23(7):596-601. PubMed ID: 10488614
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Comparison of HTK and hypertonic citrate to intraarterial cooling in human non-heart-beating kidney donors.
    Wilson CH; Asher JF; Gupta A; Vijayanand D; Wyrley-Birch H; Stamp S; Rix DA; Soomro N; Manas DM; Jaques BC; Peaston R; Talbot D
    Transplant Proc; 2007 Mar; 39(2):351-2. PubMed ID: 17362727
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Liver transplantation from non-heart-beating donors: current status and future prospects in an experimental model.
    Monbaliu D; Vekemans K; Liu Q; Heedfeld V; Wylin T; Van Breussegem A; Pirenne J
    Acta Chir Belg; 2008; 108(1):45-51. PubMed ID: 18411572
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Comparison of perfusate activities of glutathione S-transferase, alanine aminopeptidase and fatty acid binding protein in the assessment of non-heart-beating donor kidneys.
    Gok MA; Pelsers M; Glatz JF; Bhatti AA; Shenton BK; Peaston R; Cornell C; Mantle D; Talbot D
    Ann Clin Biochem; 2003 May; 40(Pt 3):252-8. PubMed ID: 12803838
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Machine perfusion as a tool to select kidneys recovered from uncontrolled donors after cardiac death.
    Reznik ON; Bagnenko SF; Loginov IV; Iljina VA; Ananyev AN; Eremich SV; Moysyuk YG
    Transplant Proc; 2008 May; 40(4):1023-6. PubMed ID: 18555105
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Hemodynamic, biochemical, and morphological characteristics during preservation of normal porcine livers by hypothermic machine perfusion.
    Monbaliu D; Vekemans K; De Vos R; Brassil J; Heedfeld V; Qiang L; D'hollander M; Roskams T; Pirenne J
    Transplant Proc; 2007 Oct; 39(8):2652-8. PubMed ID: 17954200
    [TBL] [Abstract][Full Text] [Related]  

  • 27. An in vivo autotransplant model of renal preservation: cold storage versus machine perfusion in the prevention of ischemia/reperfusion injury.
    La Manna G; Conte D; Cappuccilli ML; Nardo B; D'Addio F; Puviani L; Comai G; Bianchi F; Bertelli R; Lanci N; Donati G; Scolari MP; Faenza A; Stefoni S
    Artif Organs; 2009 Jul; 33(7):565-70. PubMed ID: 19566736
    [TBL] [Abstract][Full Text] [Related]  

  • 28. DCD pigs' kidneys analyzed by MRI to assess ex vivo their viability.
    Buchs JB; Buehler L; Moll S; Ruttimann R; Nastasi A; Kasten J; Morel P; Lazeyras F
    Transplantation; 2014 Jan; 97(2):148-53. PubMed ID: 24434482
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A novel extracorporeal kidney perfusion system: a concept model.
    Szajer M; Shah G; Kittur D; Searles B; Li L; Bruch D; Darling E
    Perfusion; 2004; 19(5):305-10. PubMed ID: 15506036
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A comparison of OPO pulsatile machine preservation practices and results.
    Szust J; Olson L; Cravero L
    J Transpl Coord; 1999 Jun; 9(2):97-100. PubMed ID: 10703389
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Experimental renal preservation by normothermic resuscitation perfusion with autologous blood.
    Bagul A; Hosgood SA; Kaushik M; Kay MD; Waller HL; Nicholson ML
    Br J Surg; 2008 Jan; 95(1):111-8. PubMed ID: 17696214
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Function and quality of kidneys after cold storage, machine perfusion, or retrograde oxygen persufflation: results from a porcine autotransplantation model.
    Treckmann J; Nagelschmidt M; Minor T; Saner F; Saad S; Paul A
    Cryobiology; 2009 Aug; 59(1):19-23. PubMed ID: 19345683
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [A new transportable machine for the preservation of livers to be transplanted by means of hyperbaric oxygenation perfusion].
    Rubbini M; Longobardi P; Rimessi A; Pinton P; Morri A; Semprini G; Pistone P; Volpinari L
    Chir Ital; 2007; 59(5):723-34. PubMed ID: 18019646
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Anti-vimentin antibody detection in recipients of heart-beating and non-heart beating donor kidneys.
    Mi H; Carter V; Gupta A; Asher J; Shenton BK; Stamp S; Wong YT; Gok MA; Talbot D
    Transplant Proc; 2005 Oct; 37(8):3269-71. PubMed ID: 16298568
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Magnetic resonance, a means for anatomically reliable imaging and noninvasive metabolic studies of kidney transplants].
    Pomer S; Hull WE; Fichtner K; Möhring K; Staehler G
    Helv Chir Acta; 1992 Oct; 59(3):465-6. PubMed ID: 1464542
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Transplantation from non heart beating donors in Newcastle upon Tyne.
    Asher J; Wilson C; Gok M; Shenton BK; Stamp S; Wong YT; Gupta A; Talbot D
    Ann Transplant; 2004; 9(1):59-61. PubMed ID: 15478894
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Machine perfusion for kidneys: how to do it at minimal cost.
    Balupuri S; Strong A; Hoernich N; Snowden C; Mohamed M; Manas D; Kirby J; Talbot D
    Transpl Int; 2001; 14(2):103-7. PubMed ID: 11370162
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A new method to harvest multiple organs from non-heart-beating donors by use of a percutaneous cardiopulmonary support machine.
    Shirakura R; Matsuda H; Nakata S; Kaneko M; Miyagawa S; Fukushima N; Kitagawa S; Naka Y; Matsumiya G; Nakano S
    Transplant Proc; 1992 Aug; 24(4):1329-30. PubMed ID: 1496576
    [No Abstract]   [Full Text] [Related]  

  • 39. The effect of machine perfusion on the arteries of porcine kidneys.
    Peerlinck ID; Barlas A; Karameris A; Papalois VE
    Exp Clin Transplant; 2005 Dec; 3(2):375-80. PubMed ID: 16417447
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Evaluation of different preservation solutions utilized in the machine perfusion of kidneys retrieved under cardiac arrest. An experimental study].
    Maio R; Costa P; Figueiredo N; Santos I
    Rev Port Cir Cardiotorac Vasc; 2007; 14(3):149-56. PubMed ID: 18167575
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.