These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
136 related articles for article (PubMed ID: 17671342)
1. Reconstruction of a ring applicator using CT imaging: impact of the reconstruction method and applicator orientation. Hellebust TP; Tanderup K; Bergstrand ES; Knutsen BH; Røislien J; Olsen DR Phys Med Biol; 2007 Aug; 52(16):4893-904. PubMed ID: 17671342 [TBL] [Abstract][Full Text] [Related]
2. Applicator reconstruction in MRI 3D image-based dose planning of brachytherapy for cervical cancer. Haack S; Nielsen SK; Lindegaard JC; Gelineck J; Tanderup K Radiother Oncol; 2009 May; 91(2):187-93. PubMed ID: 18977049 [TBL] [Abstract][Full Text] [Related]
3. Direct reconstruction of the Vienna applicator on MR images. Berger D; Dimopoulos J; Pötter R; Kirisits C Radiother Oncol; 2009 Nov; 93(2):347-51. PubMed ID: 19625096 [TBL] [Abstract][Full Text] [Related]
4. 3D/2D image registration: the impact of X-ray views and their number. Tomazevic D; Likar B; Pernus F Med Image Comput Comput Assist Interv; 2007; 10(Pt 1):450-7. PubMed ID: 18051090 [TBL] [Abstract][Full Text] [Related]
5. Relationship between sharpness and noise in CT images reconstructed with different kernels. Eldevik K; Nordhøy W; Skretting A Radiat Prot Dosimetry; 2010; 139(1-3):430-3. PubMed ID: 20181647 [TBL] [Abstract][Full Text] [Related]
6. Image-guided cervix high-dose-rate brachytherapy treatment planning: does custom computed tomography planning for each insertion provide better conformal avoidance of organs at risk? Davidson MT; Yuen J; D'Souza DP; Batchelar DL Brachytherapy; 2008; 7(1):37-42. PubMed ID: 18299111 [TBL] [Abstract][Full Text] [Related]
7. Dose mapping: validation in 4D dosimetry with measurements and application in radiotherapy follow-up evaluation. Zhang GG; Huang TC; Forster KM; Lin KP; Stevens C; Harris E; Guerrero T Comput Methods Programs Biomed; 2008 Apr; 90(1):25-37. PubMed ID: 18178288 [TBL] [Abstract][Full Text] [Related]
8. Applicator reconstruction and applicator shifts in 3D MR-based PDR brachytherapy of cervical cancer. De Leeuw AA; Moerland MA; Nomden C; Tersteeg RH; Roesink JM; Jürgenliemk-Schulz IM Radiother Oncol; 2009 Nov; 93(2):341-6. PubMed ID: 19515443 [TBL] [Abstract][Full Text] [Related]
10. Forward projection of variable angle imaging geometry to reduce reconstruction uncertainty and simplify seed matching in a backprojection algorithm. Meyer T; Kay I Phys Med Biol; 2009 Jul; 54(14):4595-604. PubMed ID: 19567943 [TBL] [Abstract][Full Text] [Related]
11. A comparative study of seed localization and dose calculation on pre- and post-implantation ultrasound and CT images for low-dose-rate prostate brachytherapy. Ali I; Algan O; Thompson S; Sindhwani P; Herman T; Cheng CY; Ahmad S Phys Med Biol; 2009 Sep; 54(18):5595-611. PubMed ID: 19717887 [TBL] [Abstract][Full Text] [Related]
12. A local region of interest image reconstruction via filtered backprojection for fan-beam differential phase-contrast computed tomography. Qi Z; Chen GH Phys Med Biol; 2007 Sep; 52(18):N417-23. PubMed ID: 17804875 [TBL] [Abstract][Full Text] [Related]
13. [The study of associated reconstruction using MV linear accelerator and cone-beam CT]. Liu ZG; Zhao J; Zhuang TG Zhongguo Yi Liao Qi Xie Za Zhi; 2006 Jul; 30(4):271-3. PubMed ID: 17039936 [TBL] [Abstract][Full Text] [Related]
14. Consequences of random and systematic reconstruction uncertainties in 3D image based brachytherapy in cervical cancer. Tanderup K; Hellebust TP; Lang S; Granfeldt J; Pötter R; Lindegaard JC; Kirisits C Radiother Oncol; 2008 Nov; 89(2):156-63. PubMed ID: 18692265 [TBL] [Abstract][Full Text] [Related]
15. Noise properties of chord-image reconstruction. Xia D; Yu L; Sidky EY; Zou Y; Zuo N; Pan X IEEE Trans Med Imaging; 2007 Oct; 26(10):1328-44. PubMed ID: 17948724 [TBL] [Abstract][Full Text] [Related]
16. Comparison of computed tomography scout based reference point localization to conventional film and axial computed tomography. Jiang L; Templeton A; Turian J; Kirk M; Zusag T; Chu JC Med Dosim; 2011; 36(4):410-5. PubMed ID: 21397490 [TBL] [Abstract][Full Text] [Related]
17. Accuracy of an electromagnetic tracking enabled afterloader based on the automated registration with CT phantom images. Gomez-Sarmiento IN; Tho D; Dürrbeck C; de Jager W; Laurendeau D; Beaulieu L Med Phys; 2024 Feb; 51(2):799-808. PubMed ID: 38127342 [TBL] [Abstract][Full Text] [Related]
18. Clinical impact of computed tomography-based image-guided brachytherapy for cervix cancer using the tandem-ring applicator - the Addenbrooke's experience. Tan LT; Coles CE; Hart C; Tait E Clin Oncol (R Coll Radiol); 2009 Apr; 21(3):175-82. PubMed ID: 19101130 [TBL] [Abstract][Full Text] [Related]
19. Shading correction algorithm for improvement of cone-beam CT images in radiotherapy. Marchant TE; Moore CJ; Rowbottom CG; MacKay RI; Williams PC Phys Med Biol; 2008 Oct; 53(20):5719-33. PubMed ID: 18824785 [TBL] [Abstract][Full Text] [Related]
20. Assessment of image quality of 64-row Dual Source versus Single Source CT coronary angiography on heart rate: a phantom study. Dikkers R; Greuter MJ; Kristanto W; van Ooijen PM; Sijens PE; Willems TP; Oudkerk M Eur J Radiol; 2009 Apr; 70(1):61-8. PubMed ID: 18308496 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]