These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
196 related articles for article (PubMed ID: 17675359)
1. A comparative study of anticoagulant control in patients on long-term warfarin using home and hospital monitoring of the international normalised ratio. Bradbury MJ; Taylor G; Short P; Williams MD Arch Dis Child; 2008 Apr; 93(4):303-6. PubMed ID: 17675359 [TBL] [Abstract][Full Text] [Related]
2. The economic costs of routine INR monitoring in infants and children--examining point-of-care devices used within the home setting compared to traditional anticoagulation clinic monitoring. Gaw JR; Crowley S; Monagle P; Jones S; Newall F Thromb Res; 2013 Jul; 132(1):26-31. PubMed ID: 23746471 [TBL] [Abstract][Full Text] [Related]
3. Home INR monitoring of oral anticoagulant therapy in children using the CoaguChek S point-of-care monitor and a robust education program. Newall F; Monagle P; Johnston L Thromb Res; 2006; 118(5):587-93. PubMed ID: 16168465 [TBL] [Abstract][Full Text] [Related]
4. Home prothrombin time monitoring: a literature analysis. Yang DT; Robetorye RS; Rodgers GM Am J Hematol; 2004 Oct; 77(2):177-86. PubMed ID: 15389909 [TBL] [Abstract][Full Text] [Related]
5. Point-of-care monitoring of oral anticoagulation therapy in children. Comparison of the CoaguChek XS system with venous INR and venous INR using an International Reference Thromboplastin preparation (rTF/95). Greenway A; Ignjatovic V; Summerhayes R; Newall F; Burgess J; DeRosa L; Monagle P Thromb Haemost; 2009 Jul; 102(1):159-65. PubMed ID: 19572081 [TBL] [Abstract][Full Text] [Related]
6. Home point-of-care international normalised ratio monitoring sustained by a non-selective educational program in children. Bajolle F; Lasne D; Elie C; Cheurfi R; Grazioli A; Traore M; Souillard P; Boudjemline Y; Jourdain P; Bonnet D Thromb Haemost; 2012 Oct; 108(4):710-8. PubMed ID: 22955724 [TBL] [Abstract][Full Text] [Related]
7. Accuracy and clinical utility of the CoaguChek XS portable international normalised ratio monitor in a pilot study of warfarin home-monitoring. Bereznicki LR; Jackson SL; Peterson GM; Jeffrey EC; Marsden KA; Jupe DM J Clin Pathol; 2007 Mar; 60(3):311-4. PubMed ID: 16751303 [TBL] [Abstract][Full Text] [Related]
8. The value of education and self-monitoring in the management of warfarin therapy in older patients with unstable control of anticoagulation. Khan TI; Kamali F; Kesteven P; Avery P; Wynne H Br J Haematol; 2004 Aug; 126(4):557-64. PubMed ID: 15287950 [TBL] [Abstract][Full Text] [Related]
9. Accuracy of the CoaguChek XS for point-of-care international normalized ratio (INR) measurement in children requiring warfarin. Bauman ME; Black KL; Massicotte MP; Bauman ML; Kuhle S; Howlett-Clyne S; Cembrowski GS; Bajzar L Thromb Haemost; 2008 Jun; 99(6):1097-103. PubMed ID: 18521514 [TBL] [Abstract][Full Text] [Related]
10. Quality of life assessment in children commencing home INR self-testing. Jones S; Monagle P; Manias E; Bruce AA; Newall F Thromb Res; 2013 Jul; 132(1):37-43. PubMed ID: 23726963 [TBL] [Abstract][Full Text] [Related]
11. Home monitoring of warfarin therapy in children with a whole blood prothrombin time monitor. Massicotte P; Marzinotto V; Vegh P; Adams M; Andrew M J Pediatr; 1995 Sep; 127(3):389-94. PubMed ID: 7658268 [TBL] [Abstract][Full Text] [Related]
12. Is home warfarin self-management effective? Results of the randomised Self-Management of Anticoagulation Research Trial. Dignan R; Keech AC; Gebski VJ; Mann KP; Hughes CF; Int J Cardiol; 2013 Oct; 168(6):5378-84. PubMed ID: 24083884 [TBL] [Abstract][Full Text] [Related]
13. Safety and Efficacy Outcomes of Home and Hospital Warfarin Management Within a Pediatric Anticoagulation Clinic. Jones S; McLoughlin S; Piovesan D; Savoia H; Monagle P; Newall F J Pediatr Hematol Oncol; 2016 Apr; 38(3):216-20. PubMed ID: 26808370 [TBL] [Abstract][Full Text] [Related]
14. Warfarin dose assessment every 4 weeks versus every 12 weeks in patients with stable international normalized ratios: a randomized trial. Schulman S; Parpia S; Stewart C; Rudd-Scott L; Julian JA; Levine M Ann Intern Med; 2011 Nov; 155(10):653-9, W201-3. PubMed ID: 22084331 [TBL] [Abstract][Full Text] [Related]
15. Effects of home prothrombin international ratio (PT-INR) management in children with mechanical prosthetic valves - Importance of individual correlations between laboratory and CoaguChek device PT-INRs. Ino N; Masutani S; Tanikawa S; Iwamoto Y; Saiki H; Ishido H; Tamura M; Senzaki H J Cardiol; 2018 Feb; 71(2):187-191. PubMed ID: 29066099 [TBL] [Abstract][Full Text] [Related]
16. Warfarin induced coagulopathy in children: assessment of a conservative approach. Bauman ME; Black K; Bauman ML; Kuhle S; Bajzar L; Massicotte MP Arch Dis Child; 2011 Feb; 96(2):164-7. PubMed ID: 21068076 [TBL] [Abstract][Full Text] [Related]
17. Safety and efficacy of warfarin in paediatric patients with prosthetic cardiac valves: a retrospective audit. Wong CS; Batchelor K; Bua J; Newall F Thromb Res; 2011 Oct; 128(4):331-4. PubMed ID: 21620442 [TBL] [Abstract][Full Text] [Related]
18. Good quality of oral anticoagulation treatment in general practice using international normalised ratio point of care testing. Løkkegaard T; Pedersen TH; Lind B; Siersma V; Waldorff FB Dan Med J; 2015 Feb; 62(2):. PubMed ID: 25634508 [TBL] [Abstract][Full Text] [Related]
19. Point of care monitoring of oral anticoagulant therapy in children: comparison of CoaguChek Plus and Thrombotest methods with venous international normalised ratio. Ignjatovic V; Barnes C; Newall F; Hamilton S; Burgess J; Monagle P Thromb Haemost; 2004 Oct; 92(4):734-7. PubMed ID: 15467903 [TBL] [Abstract][Full Text] [Related]