These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

254 related articles for article (PubMed ID: 17686963)

  • 41. Comparison of the effects of exposure to light in Harshaw LiF:Mg,Ti and LiF:Mg,Cu,P.
    Baker ST; Gilvin PJ
    Radiat Prot Dosimetry; 2007; 125(1-4):258-60. PubMed ID: 16980318
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Role of impurities in the thermoluminescence of LiF:Mg,Cu,P.
    Chen TC; Stoebe TG
    Radiat Prot Dosimetry; 2002; 100(1-4):243-6. PubMed ID: 12382869
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Comments to the author's response to our letter on "The thermoluminescence dose-response and other characteristics of the high-temperature TL in LiF:Mg,Ti (TLD-100)" by Y.S. Horowitz, L. Oster and H. Datz.
    German U; Weinstein M; Abraham A; Alfassi ZB
    Radiat Prot Dosimetry; 2008; 129(4):495-7; author reply 497. PubMed ID: 18650206
    [No Abstract]   [Full Text] [Related]  

  • 44. Thermoluminescence properties of LiMgF3 doped with Ce, Er and Dy.
    Kitis G; Furetta C; Sanipoli C
    Radiat Prot Dosimetry; 2002; 100(1-4):247-50. PubMed ID: 12382870
    [TBL] [Abstract][Full Text] [Related]  

  • 45. A new high sensitivity thermoluminescent phosphor with low residual signal and good stability to heat treatment: LiF:Mg,Cu,Na,Si.
    Tang K; Zhu H; Shen W; Liu B
    Radiat Prot Dosimetry; 2002; 100(1-4):239-42. PubMed ID: 12382868
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Comments on 'The thermoluminescence dose-response and other characteristics of the high-temperature TL in LiF: Mg.Ti (TLD-100)' by Y.S. Horowitz, L. Oster and H. Datz.
    German U; Weinstein M; Abraham A; Alfassi ZB
    Radiat Prot Dosimetry; 2008; 128(4):509-10; author reply 510-5. PubMed ID: 18420571
    [No Abstract]   [Full Text] [Related]  

  • 47. Modelling the dose response of peaks 4, 5 and 5b, in TLD-100, as a function of recombination temperature.
    Biderman S; Oster L; Horowitz YS
    Radiat Prot Dosimetry; 2006; 119(1-4):285-8. PubMed ID: 16698971
    [TBL] [Abstract][Full Text] [Related]  

  • 48. New advances in LiF:Mg,Cu,P TLDs (GR-200A).
    Shen W; Tang K; Zhu H; Liu B
    Radiat Prot Dosimetry; 2002; 100(1-4):357-60. PubMed ID: 12382897
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Thermoluminescence properties of LiF:Mg,Cu,Na,Si pellets in radiation dosimetry.
    Nam YM; Kim JL
    Radiat Prot Dosimetry; 2002; 100(1-4):467-70. PubMed ID: 12382923
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Comparison of the TL responses of two different preparations of LiF:Mg,Cu,P irradiated by photons of various energies.
    González PR; Furetta C; Azorín J
    Appl Radiat Isot; 2007 Mar; 65(3):341-4. PubMed ID: 17085055
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Energy response of a two-dimensional sheet-type LiF:Mg,Cu,P TL dosemeter to photons.
    Konnai A; Nariyama N; Ohnishi S; Odano N; Ozasa N; Ishikawa Y
    Radiat Prot Dosimetry; 2006; 120(1-4):125-8. PubMed ID: 16614093
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Low temperature studies in LiF:Mg,Cu,P.
    Mathur VK; Bandyopadhyay PK; Barkyoumb JH; Cai GG
    Radiat Prot Dosimetry; 2002; 100(1-4):103-6. PubMed ID: 12382838
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Performance of Harshaw TLD-100H two-element Dosemeter.
    Luo LZ; Rotunda JE
    Radiat Prot Dosimetry; 2006; 120(1-4):324-30. PubMed ID: 16644944
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Thermoluminescent characteristics of LiKYF5:Pr3+ and KYF4:Tm3 crystals for applications in neutron and gamma dosimetry.
    Coeck M; Vanhavere F; Khaidukov N
    Radiat Prot Dosimetry; 2002; 100(1-4):221-4. PubMed ID: 12382864
    [TBL] [Abstract][Full Text] [Related]  

  • 55. A personal thermoluminescence dosimeter using LiF:Mg,Cu,Na,Si detectors for photon fields.
    Jung H; Lee KJ; Kim JL
    Appl Radiat Isot; 2003 Jul; 59(1):87-93. PubMed ID: 12878128
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Energy response of LiF and Mg2SiO4 TLDs to 10-150 keV monoenergetic photons.
    Konnai A; Nariyama N; Ohnishi S; Odano N
    Radiat Prot Dosimetry; 2005; 115(1-4):334-6. PubMed ID: 16381741
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Influence of readout parameters on TL response, re-usability and residual signal in LiF:Mg,Cu,P.
    Tang K; Zhao J; Shen W; Zhu H; Wang Y; Liu B
    Radiat Prot Dosimetry; 2002; 100(1-4):353-6. PubMed ID: 12382896
    [TBL] [Abstract][Full Text] [Related]  

  • 58. The dose-response of Harshaw TLD-700H.
    Velbeck KJ; Luo LZ; Ramlo MJ; Rotunda JE
    Radiat Prot Dosimetry; 2006; 119(1-4):255-8. PubMed ID: 16581931
    [TBL] [Abstract][Full Text] [Related]  

  • 59. The thermoluminescence glow curves of LiF:Mg,Ti: characteristics and mechanisms.
    Horowitz YS; Oster L
    Radiat Prot Dosimetry; 2024 Jun; 200(10):919-937. PubMed ID: 38851183
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Thermoluminescence emission spectra for the LiF:Mg,Cu,Na,Si thermoluminescent materials with various concentrations of the dopants (3-D measurement).
    Lee JI; Lee D; Kim JL; Chang SY
    Radiat Prot Dosimetry; 2006; 119(1-4):293-9. PubMed ID: 16644972
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.