These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

162 related articles for article (PubMed ID: 17690539)

  • 1. Quantitative perfusion imaging with pulsed arterial spin labeling: a phantom study.
    Noguchi T; Yoshiura T; Hiwatashi A; Togao O; Yamashita K; Kobayashi K; Mihara F; Honda H
    Magn Reson Med Sci; 2007; 6(2):91-7. PubMed ID: 17690539
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Measurement of brain perfusion in newborns: pulsed arterial spin labeling (PASL) versus pseudo-continuous arterial spin labeling (pCASL).
    Boudes E; Gilbert G; Leppert IR; Tan X; Pike GB; Saint-Martin C; Wintermark P
    Neuroimage Clin; 2014; 6():126-33. PubMed ID: 25379424
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Wedge-shaped slice-selective adiabatic inversion pulse for controlling temporal width of bolus in pulsed arterial spin labeling.
    Guo J; Buxton RB; Wong EC
    Magn Reson Med; 2016 Sep; 76(3):838-47. PubMed ID: 26451521
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Optimization of simultaneous multislice EPI for concurrent functional perfusion and BOLD signal measurements at 7T.
    Ivanov D; Poser BA; Huber L; Pfeuffer J; Uludağ K
    Magn Reson Med; 2017 Jul; 78(1):121-129. PubMed ID: 27465273
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Quantification of blood flow in brain tumors: comparison of arterial spin labeling and dynamic susceptibility-weighted contrast-enhanced MR imaging.
    Warmuth C; Gunther M; Zimmer C
    Radiology; 2003 Aug; 228(2):523-32. PubMed ID: 12819338
    [TBL] [Abstract][Full Text] [Related]  

  • 6. pASL versus DSC perfusion MRI in lateralizing temporal lobe epilepsy.
    Oner AY; Eryurt B; Ucar M; Capraz I; Kurt G; Bilir E; Tali T
    Acta Radiol; 2015 Apr; 56(4):477-81. PubMed ID: 24782571
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Steady pulsed imaging and labeling scheme for noninvasive perfusion imaging.
    Xu J; Qin Q; Wu D; Hua J; Song X; McMahon MT; Northington FJ; Zhang J; van Zijl PC; Pekar JJ
    Magn Reson Med; 2016 Jan; 75(1):238-48. PubMed ID: 25732958
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Arterial spin labeling with simultaneous multi-slice echo planar imaging.
    Feinberg DA; Beckett A; Chen L
    Magn Reson Med; 2013 Dec; 70(6):1500-6. PubMed ID: 24130105
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Modeling magnetization transfer effects of Q2TIPS bolus saturation in multi-TI pulsed arterial spin labeling.
    Petr J; Schramm G; Hofheinz F; Langner J; van den Hoff J
    Magn Reson Med; 2014 Oct; 72(4):1007-14. PubMed ID: 24194169
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Whole brain perfusion measurements using arterial spin labeling with multiband acquisition.
    Kim T; Shin W; Zhao T; Beall EB; Lowe MJ; Bae KT
    Magn Reson Med; 2013 Dec; 70(6):1653-61. PubMed ID: 23878098
    [TBL] [Abstract][Full Text] [Related]  

  • 11. QUIPSS II with window-sliding saturation sequence (Q2WISE).
    Song R; Loeffler RB; Hillenbrand CM
    Magn Reson Med; 2012 Apr; 67(4):1127-32. PubMed ID: 21954083
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Using variable-rate selective excitation (VERSE) radiofrequency pulses to reduce power deposition in pulsed arterial spin labeling sequence at 7 Tesla.
    Serrai H; Buch S; Oran O; Menon RS
    Magn Reson Med; 2020 Feb; 83(2):645-652. PubMed ID: 31483524
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Arterial spin labeled carotid MR angiography: A phantom study examining the impact of technical and hemodynamic factors.
    Koktzoglou I; Giri S; Piccini D; Grodzki DM; Flanagan O; Murphy IG; Gupta N; Collins JD; Edelman RR
    Magn Reson Med; 2016 Jan; 75(1):295-301. PubMed ID: 25684192
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Regional reproducibility of pulsed arterial spin labeling perfusion imaging at 3T.
    Wang Y; Saykin AJ; Pfeuffer J; Lin C; Mosier KM; Shen L; Kim S; Hutchins GD
    Neuroimage; 2011 Jan; 54(2):1188-95. PubMed ID: 20800097
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Measurement of skeletal muscle perfusion dynamics with pseudo-continuous arterial spin labeling (pCASL): Assessment of relative labeling efficiency at rest and during hyperemia, and comparison to pulsed arterial spin labeling (PASL).
    Englund EK; Rodgers ZB; Langham MC; Mohler ER; Floyd TF; Wehrli FW
    J Magn Reson Imaging; 2016 Oct; 44(4):929-39. PubMed ID: 27043039
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Feasibility and validity of monitoring subarachnoid hemorrhage by a noninvasive MRI imaging perfusion technique: Pulsed Arterial Spin Labeling (PASL).
    Labriffe M; Ter Minassian A; Pasco-Papon A; N'Guyen S; Aubé C
    J Neuroradiol; 2015 Dec; 42(6):358-67. PubMed ID: 26048296
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Theoretical and experimental evaluation of multi-band EPI for high-resolution whole brain pCASL Imaging.
    Li X; Wang D; Auerbach EJ; Moeller S; Ugurbil K; Metzger GJ
    Neuroimage; 2015 Feb; 106():170-81. PubMed ID: 25462690
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Improved perfusion-weighted MRI by a novel double inversion with proximal labeling of both tagged and control acquisitions.
    Jahng GH; Zhu XP; Matson GB; Weiner MW; Schuff N
    Magn Reson Med; 2003 Feb; 49(2):307-14. PubMed ID: 12541251
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Assessment of vessel permeability by combining dynamic contrast-enhanced and arterial spin labeling MRI.
    Liu HL; Chang TT; Yan FX; Li CH; Lin YS; Wong AM
    NMR Biomed; 2015 Jun; 28(6):642-9. PubMed ID: 25880892
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Measurement of single-kidney glomerular filtration rate using a contrast-enhanced dynamic gradient-echo sequence and the Rutland-Patlak plot technique.
    Hackstein N; Heckrodt J; Rau WS
    J Magn Reson Imaging; 2003 Dec; 18(6):714-25. PubMed ID: 14635157
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.