180 related articles for article (PubMed ID: 17694871)
1. Automatic brachytherapy seed placement under MRI guidance.
Patriciu A; Petrisor D; Muntener M; Mazilu D; Schär M; Stoianovici D
IEEE Trans Biomed Eng; 2007 Aug; 54(8):1499-506. PubMed ID: 17694871
[TBL] [Abstract][Full Text] [Related]
2. 3D TRUS guided robot assisted prostate brachytherapy.
Wei Z; Ding M; Downey D; Fenster A
Med Image Comput Comput Assist Interv; 2005; 8(Pt 2):17-24. PubMed ID: 16685938
[TBL] [Abstract][Full Text] [Related]
3. Toward adaptive stereotactic robotic brachytherapy for prostate cancer: demonstration of an adaptive workflow incorporating inverse planning and an MR stealth robot.
Cunha JA; Hsu IC; Pouliot J; Roach Iii M; Shinohara K; Kurhanewicz J; Reed G; Stoianovici D
Minim Invasive Ther Allied Technol; 2010 Aug; 19(4):189-202. PubMed ID: 20642386
[TBL] [Abstract][Full Text] [Related]
4. Use and uncertainties of mutual information for computed tomography/ magnetic resonance (CT/MR) registration post permanent implant of the prostate.
Roberson PL; McLaughlin PW; Narayana V; Troyer S; Hixson GV; Kessler ML
Med Phys; 2005 Feb; 32(2):473-82. PubMed ID: 15789594
[TBL] [Abstract][Full Text] [Related]
5. Magnetic resonance imaging compatible robotic system for fully automated brachytherapy seed placement.
Muntener M; Patriciu A; Petrisor D; Mazilu D; Bagga H; Kavoussi L; Cleary K; Stoianovici D
Urology; 2006 Dec; 68(6):1313-7. PubMed ID: 17169653
[TBL] [Abstract][Full Text] [Related]
6. Robot-assisted prostate brachytherapy.
Yu Y; Podder T; Zhang Y; Ng WS; Misic V; Sherman J; Fu L; Fuller D; Messing E; Rubens D; Strang J; Brasacchio R
Med Image Comput Comput Assist Interv; 2006; 9(Pt 1):41-9. PubMed ID: 17354872
[TBL] [Abstract][Full Text] [Related]
7. AAPM and GEC-ESTRO guidelines for image-guided robotic brachytherapy: report of Task Group 192.
Podder TK; Beaulieu L; Caldwell B; Cormack RA; Crass JB; Dicker AP; Fenster A; Fichtinger G; Meltsner MA; Moerland MA; Nath R; Rivard MJ; Salcudean T; Song DY; Thomadsen BR; Yu Y; ;
Med Phys; 2014 Oct; 41(10):101501. PubMed ID: 25281939
[TBL] [Abstract][Full Text] [Related]
8. An ultrasound image navigation robotic prostate brachytherapy system based on US to MRI deformable image registration method.
Zhang S; Jiang S; Yang Z; Liu R; Yang Y; Liang H
Hell J Nucl Med; 2016; 19(3):223-230. PubMed ID: 27824961
[TBL] [Abstract][Full Text] [Related]
9. Robotic assistant for transperineal prostate interventions in 3T closed MRI.
Fischer GS; DiMaio SP; Iordachita II; Fichtinger G
Med Image Comput Comput Assist Interv; 2007; 10(Pt 1):425-33. PubMed ID: 18051087
[TBL] [Abstract][Full Text] [Related]
10. Observations on rotating needle insertions using a brachytherapy robot.
Meltsner MA; Ferrier NJ; Thomadsen BR
Phys Med Biol; 2007 Oct; 52(19):6027-37. PubMed ID: 17881817
[TBL] [Abstract][Full Text] [Related]
11. Structural design and analysis of pneumatic prostate seed implantation robot applied in magnetic resonance imaging environment.
Li B; Yuan L; Wang C; Guo Y
Int J Med Robot; 2022 Dec; 18(6):e2457. PubMed ID: 36063541
[TBL] [Abstract][Full Text] [Related]
12. Software strategy for robotic transperineal prostate therapy in closed-bore MRI.
Tokuda J; Fischer GS; Csoma C; DiMaio SP; Gobbi DG; Fichtinger G; Tempany CM; Hata N
Med Image Comput Comput Assist Interv; 2008; 11(Pt 2):701-9. PubMed ID: 18982666
[TBL] [Abstract][Full Text] [Related]
13. A Fully Actuated Robotic Assistant for MRI-Guided Prostate Biopsy and Brachytherapy.
Li G; Su H; Shang W; Tokuda J; Hata N; Tempany CM; Fischer GS
Proc SPIE Int Soc Opt Eng; 2013 Mar; 8671():867117. PubMed ID: 25076821
[TBL] [Abstract][Full Text] [Related]
14. Validation of a novel robot-assisted 3DUS system for real-time planning and guidance of breast interstitial HDR brachytherapy.
Poulin E; Gardi L; Barker K; Montreuil J; Fenster A; Beaulieu L
Med Phys; 2015 Dec; 42(12):6830-9. PubMed ID: 26632040
[TBL] [Abstract][Full Text] [Related]
15. Robot-assisted minimally invasive lung brachytherapy.
Trejos AL; Lin AW; Pytel MP; Patel RV; Malthaner RA
Int J Med Robot; 2007 Mar; 3():41-51. PubMed ID: 17441025
[TBL] [Abstract][Full Text] [Related]
16. Comparison of template-matching and singular-spectrum-analysis methods for imaging implanted brachytherapy seeds.
Alam SK; Mamou J; Feleppa EJ; Kalisz A; Ramachandran S
IEEE Trans Ultrason Ferroelectr Freq Control; 2011 Nov; 58(11):2484-91. PubMed ID: 22083781
[TBL] [Abstract][Full Text] [Related]
17. A comparative study of seed localization and dose calculation on pre- and post-implantation ultrasound and CT images for low-dose-rate prostate brachytherapy.
Ali I; Algan O; Thompson S; Sindhwani P; Herman T; Cheng CY; Ahmad S
Phys Med Biol; 2009 Sep; 54(18):5595-611. PubMed ID: 19717887
[TBL] [Abstract][Full Text] [Related]
18. MRI-guided prostate brachytherapy with single needle method--a planning study.
Van Gellekom MP; Moerland MA; Battermann JJ; Lagendijk JJ
Radiother Oncol; 2004 Jun; 71(3):327-32. PubMed ID: 15172149
[TBL] [Abstract][Full Text] [Related]
19. Real time ultrasound needle image simulation using multi-dimensional interpolation.
Zhu M; Salcudean SE
Med Image Comput Comput Assist Interv; 2010; 13(Pt 2):429-36. PubMed ID: 20879344
[TBL] [Abstract][Full Text] [Related]
20. High-field MRI-compatible needle placement robot for prostate interventions.
Su H; Camilo A; Cole GA; Hata N; Tempany CM; Fischer GS
Stud Health Technol Inform; 2011; 163():623-9. PubMed ID: 21335868
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]