2. [Efficacy and safety of implantable cardioverter defibrillator avoiding routine defibrillation threshold testing]. Liu Q; Zhou S; Qi S; Zeng G; Ma X; Huang H Zhong Nan Da Xue Xue Bao Yi Xue Ban; 2009 Nov; 34(11):1132-5. PubMed ID: 19952404 [TBL] [Abstract][Full Text] [Related]
3. [Comparison of treatment effectiveness of implantable cardioverter defibrillator in patients undergoing defibrillation threshold testing at the time of implantation versus no defibrillation threshold testing]. Lelakowski J; Tomala I; Rydlewska A; Majewski J; Kuniewicz M; Małecka B Pol Merkur Lekarski; 2010 Sep; 29(171):153-6. PubMed ID: 20931822 [TBL] [Abstract][Full Text] [Related]
4. High defibrillation threshold in patients with implantable defibrillator: how effective is the subcutaneous finger lead? Osswald BR; De Simone R; Most S; Tochtermann U; Tanzeem A; Karck M Eur J Cardiothorac Surg; 2009 Mar; 35(3):489-92. PubMed ID: 19144533 [TBL] [Abstract][Full Text] [Related]
5. Effects of shock polarity reversal on defibrillation threshold in an implantable cardioverter-defibrillator. Zienciuk A; Lubiński A; Królak T; Lewicka-Nowak E; Kempa M; Pazdyga A; Raczak G Kardiol Pol; 2007 May; 65(5):495-500; discussion 501-2. PubMed ID: 17577846 [TBL] [Abstract][Full Text] [Related]
6. Non-determinable defibrillation threshold and inefficacy of implantable cardioverter/defibrillator shocks due to defective connections of the defibrillator lead terminals in the device header port. Maagh P; Trappe HJ; Meissner A Europace; 2007 Dec; 9(12):1161-2. PubMed ID: 17913694 [TBL] [Abstract][Full Text] [Related]
15. ICD Implantation in infants and small children: the extracardiac technique. Kriebel T; Ruschewski W; Gonzalez y Gonzalez M; Walter K; Kroll J; Kampmann C; Heinemann M; Schneider H; Paul T Pacing Clin Electrophysiol; 2006 Dec; 29(12):1319-25. PubMed ID: 17201837 [TBL] [Abstract][Full Text] [Related]
16. Should Single-Coil Implantable Cardioverter Defibrillator Leads Be Used in all Patients? Almehmadi F; Manlucu J Card Electrophysiol Clin; 2018 Mar; 10(1):59-66. PubMed ID: 29428142 [TBL] [Abstract][Full Text] [Related]
17. Defibrillation threshold testing and neurologic outcome. Karaoğuz R Anadolu Kardiyol Derg; 2007 Jul; 7 Suppl 1():47-9. PubMed ID: 17584679 [TBL] [Abstract][Full Text] [Related]
18. European Resuscitation Council Guidelines for Resuscitation 2010 Section 3. Electrical therapies: automated external defibrillators, defibrillation, cardioversion and pacing. Deakin CD; Nolan JP; Sunde K; Koster RW Resuscitation; 2010 Oct; 81(10):1293-304. PubMed ID: 20956050 [No Abstract] [Full Text] [Related]