BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

245 related articles for article (PubMed ID: 17713259)

  • 1. [Finite element method and computational fluid dynamics used in the analysis of a stent].
    Liang D; Yang D; Qi M
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2007 Jun; 24(3):549-53. PubMed ID: 17713259
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Cardiovascular stent design and vessel stresses: a finite element analysis.
    Lally C; Dolan F; Prendergast PJ
    J Biomech; 2005 Aug; 38(8):1574-81. PubMed ID: 15958213
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Alterations in regional vascular geometry produced by theoretical stent implantation influence distributions of wall shear stress: analysis of a curved coronary artery using 3D computational fluid dynamics modeling.
    LaDisa JF; Olson LE; Douglas HA; Warltier DC; Kersten JR; Pagel PS
    Biomed Eng Online; 2006 Jun; 5():40. PubMed ID: 16780592
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Optimization of a helical flow inducer of endovascular stent based on the principle of swirling flow in arterial system].
    Teng X; Deng X
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2010 Apr; 27(2):429-34. PubMed ID: 20481333
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Finite element analysis and stent design: Reduction of dogboning.
    De Beule M; Van Impe R; Verhegghe B; Segers P; Verdonck P
    Technol Health Care; 2006; 14(4-5):233-41. PubMed ID: 17065746
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Design optimization of endovascular stent by finite element method].
    Wang W; Wang L; Yang D; Qi M
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2008 Apr; 25(2):372-7. PubMed ID: 18610625
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effects of design parameters on the radial force of percutaneous aortic valve stents.
    Kumar GV; Mathew L
    Cardiovasc Revasc Med; 2010; 11(2):101-4. PubMed ID: 20347800
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Stent expansion in curved vessel and their interactions: a finite element analysis.
    Wu W; Wang WQ; Yang DZ; Qi M
    J Biomech; 2007; 40(11):2580-5. PubMed ID: 17198706
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Axial stent strut angle influences wall shear stress after stent implantation: analysis using 3D computational fluid dynamics models of stent foreshortening.
    LaDisa JF; Olson LE; Hettrick DA; Warltier DC; Kersten JR; Pagel PS
    Biomed Eng Online; 2005 Oct; 4():59. PubMed ID: 16250918
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Stresses in peripheral arteries following stent placement: a finite element analysis.
    Early M; Lally C; Prendergast PJ; Kelly DJ
    Comput Methods Biomech Biomed Engin; 2009 Feb; 12(1):25-33. PubMed ID: 18821189
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Developing pulsatile flow in a deployed coronary stent.
    Rajamohan D; Banerjee RK; Back LH; Ibrahim AA; Jog MA
    J Biomech Eng; 2006 Jun; 128(3):347-59. PubMed ID: 16706584
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Multiobjective design optimisation of coronary stents.
    Pant S; Limbert G; Curzen NP; Bressloff NW
    Biomaterials; 2011 Nov; 32(31):7755-73. PubMed ID: 21821283
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Analysis of the transient expansion behavior and design optimization of coronary stents by finite element method.
    Wang WQ; Liang DK; Yang DZ; Qi M
    J Biomech; 2006; 39(1):21-32. PubMed ID: 16271584
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biomaterial optimization in a percutaneous aortic valve stent using finite element analysis.
    Kumar GV; Mathew L
    Cardiovasc Revasc Med; 2009; 10(4):247-51. PubMed ID: 19815172
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Circumferential vascular deformation after stent implantation alters wall shear stress evaluated with time-dependent 3D computational fluid dynamics models.
    LaDisa JF; Olson LE; Guler I; Hettrick DA; Kersten JR; Warltier DC; Pagel PS
    J Appl Physiol (1985); 2005 Mar; 98(3):947-57. PubMed ID: 15531564
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Flow dynamics in anatomical models of abdominal aortic aneurysms: computational analysis of pulsatile flow.
    Finol EA; Amon CH
    Acta Cient Venez; 2003; 54(1):43-9. PubMed ID: 14515766
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Finite element analysis of the mechanical property of the resistance to compressing of the coronary stent].
    Wang W; Yang D; Qi M
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2006 Oct; 23(5):1008-12. PubMed ID: 17121342
    [TBL] [Abstract][Full Text] [Related]  

  • 18. On the finite element modelling of balloon-expandable stents.
    Ju F; Xia Z; Sasaki K
    J Mech Behav Biomed Mater; 2008 Jan; 1(1):86-95. PubMed ID: 19627774
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Finite element analysis of the expansion behavior of coronary stents].
    Wang W; Yang D; Qi M
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2006 Dec; 23(6):1258-62, 1266. PubMed ID: 17228721
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effects of stent geometry on local flow dynamics and resulting platelet deposition in an in vitro model.
    Duraiswamy N; Cesar JM; Schoephoerster RT; Moore JE
    Biorheology; 2008; 45(5):547-61. PubMed ID: 19065004
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.