These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

159 related articles for article (PubMed ID: 17716184)

  • 1. BioForce Nanosciences, Inc.
    Henderson E
    Nanomedicine (Lond); 2007 Jun; 2(3):391-6. PubMed ID: 17716184
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Nanofluidic technology for biomolecule applications: a critical review.
    Napoli M; Eijkel JC; Pennathur S
    Lab Chip; 2010 Apr; 10(8):957-85. PubMed ID: 20358103
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Cell microarrays based on hydrogel microstructures for the application to cell-based biosensor.
    Koh WG
    Methods Mol Biol; 2011; 671():133-45. PubMed ID: 20967627
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Solution processed micro- and nano-bioarrays for multiplexed biosensing.
    Arrabito G; Pignataro B
    Anal Chem; 2012 Jul; 84(13):5450-62. PubMed ID: 22591457
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Microsystems technology and biosensing.
    Sathuluri RR; Yamamura S; Tamiya E
    Adv Biochem Eng Biotechnol; 2008; 109():285-350. PubMed ID: 17999038
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Spintronic platforms for biomedical applications.
    Freitas PP; Cardoso FA; Martins VC; Martins SA; Loureiro J; Amaral J; Chaves RC; Cardoso S; Fonseca LP; Sebastião AM; Pannetier-Lecoeur M; Fermon C
    Lab Chip; 2012 Feb; 12(3):546-57. PubMed ID: 22146898
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Disposable microfluidic devices: fabrication, function, and application.
    Fiorini GS; Chiu DT
    Biotechniques; 2005 Mar; 38(3):429-46. PubMed ID: 15786809
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Dielectrophoretic platforms for bio-microfluidic systems.
    Khoshmanesh K; Nahavandi S; Baratchi S; Mitchell A; Kalantar-zadeh K
    Biosens Bioelectron; 2011 Jan; 26(5):1800-14. PubMed ID: 20933384
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Sample flow switching techniques on microfluidic chips.
    Pan YJ; Lin JJ; Luo WJ; Yang RJ
    Biosens Bioelectron; 2006 Feb; 21(8):1644-8. PubMed ID: 16112854
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Microfluidic-integrated biosensors: prospects for point-of-care diagnostics.
    Kumar S; Kumar S; Ali MA; Anand P; Agrawal VV; John R; Maji S; Malhotra BD
    Biotechnol J; 2013 Nov; 8(11):1267-79. PubMed ID: 24019250
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Merging microfluidics with microarray-based bioassays.
    Situma C; Hashimoto M; Soper SA
    Biomol Eng; 2006 Oct; 23(5):213-31. PubMed ID: 16905357
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Graphene nano-ink biosensor arrays on a microfluidic paper for multiplexed detection of metabolites.
    Labroo P; Cui Y
    Anal Chim Acta; 2014 Feb; 813():90-6. PubMed ID: 24528665
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dividable membrane with multi-reaction wells for microarray biochips.
    Chang YJ; Hu CY; Yin LT; Chang CH; Su HJ
    J Biosci Bioeng; 2008 Jul; 106(1):59-64. PubMed ID: 18691532
    [TBL] [Abstract][Full Text] [Related]  

  • 14. What is nanomedicine?
    Freitas RA
    Nanomedicine; 2005 Mar; 1(1):2-9. PubMed ID: 17292052
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biosensors with label-free detection designed for diagnostic applications.
    Rapp BE; Gruhl FJ; Länge K
    Anal Bioanal Chem; 2010 Nov; 398(6):2403-12. PubMed ID: 20563563
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Selective in situ functionalization of biosensors on LOC devices using laminar co-flow.
    Parra-Cabrera C; Sporer C; Rodriguez-Villareal I; Rodriguez-Trujillo R; Homs-Corbera A; Samitier J
    Lab Chip; 2012 Oct; 12(20):4143-50. PubMed ID: 22868270
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Whole-cell biochips for bio-sensing: integration of live cells and inanimate surfaces.
    Ben-Yoav H; Melamed S; Freeman A; Shacham-Diamand Y; Belkin S
    Crit Rev Biotechnol; 2011 Dec; 31(4):337-53. PubMed ID: 21190513
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A microbead array chemical sensor using capillary-based sample introduction: toward the development of an "electronic tongue".
    Sohn YS; Goodey A; Anslyn EV; McDevitt JT; Shear JB; Neikirk DP
    Biosens Bioelectron; 2005 Aug; 21(2):303-12. PubMed ID: 16023957
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Microfluidic systems integrated with two-dimensional surface plasmon resonance phase imaging systems for microarray immunoassay.
    Lee KH; Su YD; Chen SJ; Tseng FG; Lee GB
    Biosens Bioelectron; 2007 Nov; 23(4):466-72. PubMed ID: 17618110
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Biosensors based on cantilevers.
    Alvarez M; Carrascosa LG; Zinoviev K; Plaza JA; Lechuga LM
    Methods Mol Biol; 2009; 504():51-71. PubMed ID: 19159090
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.