These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

88 related articles for article (PubMed ID: 17718697)

  • 1. Effect of body positioning during transcranial Doppler detection of right-to-left shunts.
    Lao AY; Sharma VK; Tsivgoulis G; Malkoff MD; Alexandrov AV; Frey JL
    Eur J Neurol; 2007 Sep; 14(9):1035-9. PubMed ID: 17718697
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effects of posture on right-to-left shunt detection by contrast transcranial doppler.
    Agustin SJ; Yumul MP; Kalaw AJ; Teo BC; Eng J; Phua Z; Singh R; Gan RN; Venketasubramanian N
    Stroke; 2011 Aug; 42(8):2201-5. PubMed ID: 21757670
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Body positions in the diagnosis of right-to-left shunt by contrast transcranial Doppler.
    Han K; Xing Y; Yang Y; Chao AC; Sheng WY; Hu HH; Wu J
    Ultrasound Med Biol; 2015 Sep; 41(9):2376-81. PubMed ID: 26067785
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effects of patient position on right-to-left shunt detection by contrast transcranial Doppler.
    Wu CT; Han K; Guo ZN; Yang Y; Gao YS; Bai J; Xing YQ
    Ultrasound Med Biol; 2015 Mar; 41(3):654-8. PubMed ID: 25683218
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Detection of right-to-left shunts: comparison between the International Consensus and Spencer Logarithmic Scale criteria.
    Lao AY; Sharma VK; Tsivgoulis G; Frey JL; Malkoff MD; Navarro JC; Alexandrov AV
    J Neuroimaging; 2008 Oct; 18(4):402-6. PubMed ID: 18333839
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Optimizing the technique of contrast transcranial Doppler ultrasound in the detection of right-to-left shunts.
    Droste DW; Lakemeier S; Wichter T; Stypmann J; Dittrich R; Ritter M; Moeller M; Freund M; Ringelstein EB
    Stroke; 2002 Sep; 33(9):2211-6. PubMed ID: 12215589
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Sensitivity of brachial versus femoral vein injection of agitated saline to detect right-to-left shunts with Transcranial Doppler.
    Gevorgyan R; Perlowski A; Shenoda M; Mojadidi MK; Agrawal H; Tobis JM
    Catheter Cardiovasc Interv; 2014 Nov; 84(6):992-6. PubMed ID: 24403023
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Transcranial Doppler: Does Addition of Blood to Agitated Saline Affect Sensitivity for Detecting Cardiac Right-to-Left Shunt?
    Mojadidi MK; Zhang L; Chugh Y; Eshtehardi P; Hovnanians N; Gevorgyan R; Mojaddedi S; Nezami N; Zaman MO; Rafique A; Villablanca PA; Tobis JM
    Echocardiography; 2016 Aug; 33(8):1219-27. PubMed ID: 27095475
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Contrast transcranial doppler ultrasound in the detection of right-to-left shunts : time window and threshold in microbubble numbers.
    Droste DW; Silling K; Stypmann J; Grude M; Kemény V; Wichter T; Kühne K; Ringelstein EB
    Stroke; 2000 Jul; 31(7):1640-5. PubMed ID: 10884466
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Safety of transcranial Doppler 'bubble study' for identification of right to left shunts: an international multicentre study.
    Tsivgoulis G; Stamboulis E; Sharma VK; Heliopoulos I; Voumvourakis K; Teoh HL; Vadikolias K; Triantafyllou N; Chan BP; Vasdekis SN; Piperidou C
    J Neurol Neurosurg Psychiatry; 2011 Nov; 82(11):1206-8. PubMed ID: 20971751
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Detection of right-to-left shunts may be associated with body size.
    Iguchi Y; Kimura K; Kobayashi K; Aoki J; Sakai K; Terasawa Y; Uemura J; Shibazaki K
    J Neuroimaging; 2010 Apr; 20(2):130-3. PubMed ID: 19226342
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Transcranial Doppler with bubble study as a method to detect extracardiac right-to-left shunts in patients with ischemic stroke.
    Goutman SA; Katzan IL; Gupta R
    J Neuroimaging; 2013 Oct; 23(4):523-5. PubMed ID: 22928688
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Postural effect in patients with patent foramen ovale: evaluation of right-to-left shunt with transcranial Doppler and transthoracic echocardiography and correlation with arterial oxygen saturation].
    Lucreziotti S; Debenedetti C; Massironi L; Mantero A; Di Marco F; Chessa M; Carugo S
    G Ital Cardiol (Rome); 2017 Jun; 18(6):519-524. PubMed ID: 28631766
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Is transcranial Doppler for the detection of venous-to-arterial circulation shunts reproducible?
    Sastry S; Daly K; Chengodu T; McCollum C
    Cerebrovasc Dis; 2007; 23(5-6):424-9. PubMed ID: 17406112
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Alternatives to transtemporal approach of transcranial Doppler for the detection of right-to-left cardiac shunt.
    Sharma VK; Teoh HL; Chan BP
    J Neurol Sci; 2009 Apr; 279(1-2):124-5; discussion 125. PubMed ID: 19171356
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Detection of right-to-left shunt with ultrasound contrast agent and transcranial Doppler sonography.
    Jauss M; Zanette E
    Cerebrovasc Dis; 2000; 10(6):490-6. PubMed ID: 11070388
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Postural dependency of right to left shunt: role of contrast-enhanced transcranial Doppler and its potential clinical implications.
    Caputi L; Carriero MR; Parati EA; Onorato E; Casilli F; Berti M; Anzola GP
    Stroke; 2008 Aug; 39(8):2380-1. PubMed ID: 18535277
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Two different days of transcranial Doppler examinations should be performed for detection of right-to-left shunt in acute stroke patients.
    Aoki J; Kimura K; Iguchi Y; Sakai K; Sakamoto Y; Terasawa Y; Shibazaki K; Kobayashi K
    J Neuroimaging; 2013 Apr; 23(2):175-9. PubMed ID: 22188538
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Right-to-left-shunt detected by c-TCD using the orbital window in comparison with temporal bone windows.
    Kobayashi K; Kimura K; Iguchi Y; Sakai K; Aoki J; Iwanaga T; Shibazaki K
    J Neuroimaging; 2012 Jan; 22(1):80-4. PubMed ID: 21143546
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Right-to-left shunt detection using contrast-enhanced transcranial Doppler: A comparison of provocation maneuvers between coughing and a modified Valsalva maneuver.
    Wang SB; Wang XC; Ma Y; Liu KD; Xing YQ
    PLoS One; 2017; 12(4):e0175049. PubMed ID: 28384297
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.