BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

359 related articles for article (PubMed ID: 17723734)

  • 1. Potentiometric membrane sensor based on 6-(4-nitrophenyl)-2,4-diphenyl-3,5-diaza-bicyclo[3.1.0]hex-2-ene for detection of Sn(II) in real samples.
    Arvand M; Moghimi AM; Afshari A; Mahmoodi N
    Anal Chim Acta; 2006 Oct; 579(1):102-8. PubMed ID: 17723734
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Batch and flow measurement of hydrogen ions in highly acidic media using 2-(4-methoxy phenyl) 6-(4-nitrophenyl)-4-phenyl-1,3-diazabicyclo [3.1.0] hex-3-ene as an H+-selective ionophore.
    Arvand M; Ghaiuri K
    Talanta; 2009 Aug; 79(3):863-70. PubMed ID: 19576457
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A bromide selective polymeric membrane electrode based on Zn(II) macrocyclic complex.
    Singh AK; Mehtab S; Saxena P
    Talanta; 2006 Jul; 69(5):1143-8. PubMed ID: 18970695
    [TBL] [Abstract][Full Text] [Related]  

  • 4. PVC membrane potentiometric sensor based on 5-pyridino-2,8-dithia[9](2,9)-1,10-phenanthroline-phane for selective determination of neodymium(III).
    Shamsipur M; Hosseini M; Alizadeh K; Mousavi MF; Garau A; Lippolis V; Yari A
    Anal Chem; 2005 Jan; 77(1):276-83. PubMed ID: 15623306
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Strontium(II)-selective electrode based on a macrocyclic tetraamide.
    Singh AK; Saxena P; Mehtab S; Gupta B
    Talanta; 2006 Apr; 69(2):521-6. PubMed ID: 18970598
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Application of 8-amino-N-(2-hydroxybenzylidene)naphthyl amine as a neutral ionophore in the construction of a lanthanum ion-selective sensor.
    Ganjali MR; Norouzi P; Alizadeh T; Adib M
    Anal Chim Acta; 2006 Aug; 576(2):275-82. PubMed ID: 17723643
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Novel potentiometric membrane sensor based on 6-(4-nitrophenyl)-2-phenyl-4,4-dipropyl-3,5-diaza-bicyclo[3,1,0] hex-2-ene for detection of strontium (II) ions at trace levels.
    Zanjanchi MA; Arvand M; Islamnezhad A; Mahmoodi NO
    Talanta; 2007 Nov; 74(1):125-31. PubMed ID: 18371621
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The first use of a Rh(III) complex as a novel ionophore for thiocyanate-selective polymeric membrane electrodes.
    Shamsipur M; Ershad S; Samadi N; Rezvani AR; Haddadzadeh H
    Talanta; 2005 Feb; 65(4):991-7. PubMed ID: 18969900
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ion-selective electrode for aluminum determination in pharmaceutical substances, tea leaves and water samples.
    Arvand M; Asadollahzadeh SA
    Talanta; 2008 May; 75(4):1046-54. PubMed ID: 18585182
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Neutral carriers based polymeric membrane electrodes for selective determination of mercury (II).
    Gupta VK; Singh AK; Al Khayat M; Gupta B
    Anal Chim Acta; 2007 May; 590(1):81-90. PubMed ID: 17416226
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Novel lipoate-selective membrane sensor for the flow injection determination of alpha-lipoic acid in pharmaceutical preparations and urine.
    Abbas MN; Radwan AA
    Talanta; 2008 Feb; 74(5):1113-21. PubMed ID: 18371758
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Selective electrochemical sensor for copper (II) ion based on chelating ionophores.
    Singh AK; Mehtab S; Jain AK
    Anal Chim Acta; 2006 Aug; 575(1):25-31. PubMed ID: 17723567
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A new Zn(II)-selective potentiometric sensor based on 4-tert-butylcalix[4]arene in PVC matrix.
    Gupta VK; Goyal RN; Al Khayat M; Kumar P; Bachheti N
    Talanta; 2006 Jul; 69(5):1149-55. PubMed ID: 18970696
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Multi-walled carbon nanotubes-ionic liquid-carbon paste electrode as a super selectivity sensor: application to potentiometric monitoring of mercury ion(II).
    Khani H; Rofouei MK; Arab P; Gupta VK; Vafaei Z
    J Hazard Mater; 2010 Nov; 183(1-3):402-9. PubMed ID: 20692088
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparative studies of praseodymium(III) selective sensors based on newly synthesized Schiff's bases.
    Gupta VK; Goyal RN; Pal MK; Sharma RA
    Anal Chim Acta; 2009 Oct; 653(2):161-6. PubMed ID: 19808108
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Mercury(II) ion-selective polymeric membrane sensor based on a recently synthesized Schiff base.
    Mashhadizadeh MH; Sheikhshoaie I
    Talanta; 2003 May; 60(1):73-80. PubMed ID: 18969027
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A Fast Response Membrane Sensor based on Ethyl 1, 2, 3, 4-tetrahydro-6-methyl-4-phenyl-2-thioxopyrimidine-5-carboxylate for Detection of Lanthanum (III) Ions at Wide Concentration Range.
    Islamnezhad A; Zanjanchi MA; Shariati S; Abri A
    Acta Chim Slov; 2011 Mar; 58(1):46-52. PubMed ID: 24061942
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Determination of gadolinium(III) ions in soil and sediment samples by a novel gadolinium membrane sensor based on 6-methyl-4-{[1-(2-thienyl)methylidene]amino}3-thioxo-3,4-dihydro-1,2,4-triazin-5-(2H)-one.
    Zamani HA; Rajabzadeh G; Ganjali MR; Norouzi P
    Anal Chim Acta; 2007 Aug; 598(1):51-7. PubMed ID: 17693306
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Lead(II) ion-selective electrode based on polyaminoanthraquinone particles with intrinsic conductivity.
    Li XG; Ma XL; Huang MR
    Talanta; 2009 Apr; 78(2):498-505. PubMed ID: 19203615
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Optimization of polymeric triiodide membrane electrode based on clozapine-triiodide ion-pair using experimental design.
    Farhadi K; Bahram M; Shokatynia D; Salehiyan F
    Talanta; 2008 Jul; 76(2):320-6. PubMed ID: 18585284
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 18.