These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

104 related articles for article (PubMed ID: 17723737)

  • 1. Models and objective functions for the optimisation of selectivity in reversed-phase liquid chromatography.
    García-Alvarez-Coque MC; Torres-Lapasió JR; Baeza-Baeza JJ
    Anal Chim Acta; 2006 Oct; 579(2):125-45. PubMed ID: 17723737
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Retention models for isocratic and gradient elution in reversed-phase liquid chromatography.
    Nikitas P; Pappa-Louisi A
    J Chromatogr A; 2009 Mar; 1216(10):1737-55. PubMed ID: 18838140
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Levels in the interpretive optimisation of selectivity in high-performance liquid chromatography: a magical mystery tour.
    Torres-Lapasió JR; García-Alvarez-Coque MC
    J Chromatogr A; 2006 Jul; 1120(1-2):308-21. PubMed ID: 16563407
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Approaches to model the retention and peak profile in linear gradient reversed-phase liquid chromatography.
    Baeza-Baeza JJ; Ortiz-Bolsico C; Torres-Lapasió JR; García-Álvarez-Coque MC
    J Chromatogr A; 2013 Apr; 1284():28-35. PubMed ID: 23453677
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Combined effect of solvent content, temperature and pH on the chromatographic behaviour of ionisable compounds II: benefits of the simultaneous optimisation.
    Pous-Torres S; Torres-Lapasió JR; Baeza-Baeza JJ; García-Alvarez-Coque MC
    J Chromatogr A; 2008 Jun; 1193(1-2):117-28. PubMed ID: 18452933
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Simple algorithms for fitting and optimisation for multilinear gradient elution in reversed-phase liquid chromatography.
    Nikitas P; Pappa-Louisi A; Papageorgiou A
    J Chromatogr A; 2007 Jul; 1157(1-2):178-86. PubMed ID: 17498723
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Combined effect of solvent content, temperature and pH on the chromatographic behaviour of ionisable compounds. III: Considerations about robustness.
    Pous-Torres S; Torres-Lapasió JR; Baeza-Baeza JJ; García-Alvarez-Coque MC
    J Chromatogr A; 2009 Dec; 1216(51):8891-903. PubMed ID: 19909960
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Multilinear gradient elution optimisation in reversed-phase liquid chromatography using genetic algorithms.
    Nikitas P; Pappa-Louisi A; Agrafiotou P
    J Chromatogr A; 2006 Jul; 1120(1-2):299-307. PubMed ID: 16426624
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Determination of selectivity differences for basic compounds in gradient reverse phase high performance liquid chromatography under high pH conditions by partial least squares modelling.
    Fornal E; Borman P; Luscombe C
    Anal Chim Acta; 2006 Jun; 570(2):267-76. PubMed ID: 17723408
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Multimode gradient elution in reversed-phase liquid chromatography: application to retention prediction and separation optimization of a set of amino acids in gradient runs involving simultaneous variations of mobile-phase composition, flow rate, and temperature.
    Pappa-Louisi A; Nikitas P; Papachristos K; Balkatzopoulou P
    Anal Chem; 2009 Feb; 81(3):1217-23. PubMed ID: 19123773
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Combined effect of solvent content, temperature and pH on the chromatographic behaviour of ionisable compounds.
    Pous-Torres S; Torres-Lapasió JR; Baeza-Baeza JJ; García-Alvarez-Coque MC
    J Chromatogr A; 2007 Sep; 1163(1-2):49-62. PubMed ID: 17585924
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Prediction of elution bandwidth for purine compounds by a retention model in reversed-phase HPLC with linear-gradient elution.
    Jin CH; Lee JW; Row KH
    J Sep Sci; 2008 Jan; 31(1):23-9. PubMed ID: 18064619
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Combined effect of temperature and organic modifier concentration on the retention under single mode gradient conditions in reversed-phase HPLC.
    Pappa-Louisi A; Nikitas P; Zisi C; Papachristos K
    J Sep Sci; 2008 Sep; 31(16-17):2953-61. PubMed ID: 18785145
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Robust interpretive optimisation in high-performance liquid chromatography considering uncertainties in peak position.
    Vivó-Truyols G; Concha-Herrera V; Torres-Lapasió JR; García-Alvarez-Coque MC
    J Chromatogr A; 2005 Nov; 1096(1-2):123-32. PubMed ID: 16301075
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Prediction of analyte retention for ion chromatography separations performed using elution profiles comprising multiple isocratic and gradient steps.
    Shellie RA; Ng BK; Dicinoski GW; Poynter SD; O'Reilly JW; Pohl CA; Haddad PR
    Anal Chem; 2008 Apr; 80(7):2474-82. PubMed ID: 18327920
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Interpretive optimisation of organic solvent content and flow-rate in the separation of beta-blockers with a Chromolith RP-18e column.
    Pous-Torres S; Torres-Lapasió JR; Ruiz-Angel MJ; García-Alvarez-Coque MC
    J Sep Sci; 2009 Aug; 32(15-16):2793-803. PubMed ID: 19603390
    [TBL] [Abstract][Full Text] [Related]  

  • 17. New practical algorithm for modelling analyte recovery in bioanalytical reversed phase and mixed-mode solid phase extraction.
    Hendriks G; Uges DR; Franke JP
    J Pharm Biomed Anal; 2008 Sep; 48(1):158-70. PubMed ID: 18579329
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Review on modelling aspects in reversed-phase liquid chromatographic quantitative structure-retention relationships.
    Put R; Vander Heyden Y
    Anal Chim Acta; 2007 Oct; 602(2):164-72. PubMed ID: 17933600
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Modeling the combined effect of temperature and organic modifier content on reversed-phase chromatographic retention. Effectiveness of derived models in isocratic and isothermal mode retention prediction.
    Pappa-Louisi A; Nikitas P; Papachristos K; Zisi C
    J Chromatogr A; 2008 Aug; 1201(1):27-34. PubMed ID: 18554606
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Development of an ion chromatographic gradient retention model from isocratic elution experiments.
    Bolanca T; Cerjan-Stefanović S; Lusa M; Rogosić M; Ukić S
    J Chromatogr A; 2006 Jul; 1121(2):228-35. PubMed ID: 16698028
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.