BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

144 related articles for article (PubMed ID: 1774390)

  • 1. Bioimpedance versus thermodilution cardiac output measurement: the Bomed NCCOM3 after coronary bypass surgery.
    Thomas AN; Ryan J; Doran BR; Pollard BJ
    Intensive Care Med; 1991; 17(7):383-6. PubMed ID: 1774390
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Thoracic electrical bioimpedance measurement of cardiac output in postaortocoronary bypass patients.
    Sageman WS; Amundson DE
    Crit Care Med; 1993 Aug; 21(8):1139-42. PubMed ID: 8339577
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Cardiac output can be reliably measured noninvasively after coronary artery bypass grafting operation.
    Kööbi T; Kaukinen S; Turjanmaa VM
    Crit Care Med; 1999 Oct; 27(10):2206-11. PubMed ID: 10548208
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A comparison of hemodynamic parameters derived from transthoracic electrical bioimpedance with those parameters obtained by thermodilution and ventricular angiography.
    Marik PE; Pendelton JE; Smith R
    Crit Care Med; 1997 Sep; 25(9):1545-50. PubMed ID: 9295830
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Cardiac output measurement after coronary artery bypass grafting using bolus thermodilution, continuous thermodilution, and whole-body impedance cardiography.
    Kaukinen S; Kööbi T; Bi Y; Turjanmaa VM
    J Cardiothorac Vasc Anesth; 2003 Apr; 17(2):199-203. PubMed ID: 12698402
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy of the BoMED NCCOM3 bioimpedance cardiac output monitor during induced hypotension: an experimental study in dogs.
    Tibballs J; Hochmann M; Osborne A; Carter B
    Anaesth Intensive Care; 1992 Aug; 20(3):326-31. PubMed ID: 1524173
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Cardiac output determination from endotracheally measured impedance cardiography: clinical evaluation of endotracheal cardiac output monitor.
    Maus TM; Reber B; Banks DA; Berry A; Guerrero E; Manecke GR
    J Cardiothorac Vasc Anesth; 2011 Oct; 25(5):770-5. PubMed ID: 21354828
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Clinical evaluation of a new tracheal impedance cardiography method.
    van der Kleij SC; Koolen BB; Newhall DA; Gerritse BM; Rosseel PM; Rijpstra TA; Geisler FE; van der Meer NJ
    Anaesthesia; 2012 Jul; 67(7):729-33. PubMed ID: 22420758
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of impedance cardiography: comparison of NCCOM3-R7 with Fick and thermodilution methods.
    Yakimets J; Jensen L
    Heart Lung; 1995; 24(3):194-206. PubMed ID: 7622393
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Cardiac output measurements with electrical velocimetry in patients undergoing CABG surgery: a comparison with intermittent thermodilution.
    Mekis D; Kamenik M; Starc V; Jeretin S
    Eur J Anaesthesiol; 2008 Mar; 25(3):237-42. PubMed ID: 17850685
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Cardiac output monitoring by impedance cardiography in cardiac surgery].
    Shimizu H; Seki S; Mizuguchi A; Tsuchida H; Watanabe H; Namiki A
    Masui; 1990 Apr; 39(4):508-12. PubMed ID: 2362347
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Esophageal electrodes allow precise assessment of cardiac output by bioimpedance.
    Balestra B; Malacrida R; Leonardi L; Suter P; Marone C
    Crit Care Med; 1992 Jan; 20(1):62-7. PubMed ID: 1729048
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Equivalence of bioimpedance and thermodilution in measuring cardiac index after cardiac surgery.
    Sageman WS; Riffenburgh RH; Spiess BD
    J Cardiothorac Vasc Anesth; 2002 Feb; 16(1):8-14. PubMed ID: 11854871
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Whole-body impedance cardiography in the measurement of cardiac output.
    Kööbi T; Kaukinen S; Turjanmaa VM; Uusitalo AJ
    Crit Care Med; 1997 May; 25(5):779-85. PubMed ID: 9187596
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Determination of cardiac output during positive end-expiratory pressure--noninvasive electrical bioimpedance compared with standard thermodilution.
    Castor G; Molter G; Helms J; Niedermark I; Altmayer P
    Crit Care Med; 1990 May; 18(5):544-6. PubMed ID: 2183967
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Intraoperative cardiac output monitoring: comparison of impedance cardiography and thermodilution.
    Perrino AC; Lippman A; Ariyan C; O'Connor TZ; Luther M
    J Cardiothorac Vasc Anesth; 1994 Feb; 8(1):24-9. PubMed ID: 8167281
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of transthoracic electrical bioimpedance cardiac output measurement with thermodilution method in post coronary artery bypass graft patients.
    Sharma V; Singh A; Kansara B; Karlekar A
    Ann Card Anaesth; 2011; 14(2):104-10. PubMed ID: 21636930
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The effect of lung injury and excessive lung fluid, on impedance cardiac output measurements, in the critically ill.
    Critchley LA; Calcroft RM; Tan PY; Kew J; Critchley JA
    Intensive Care Med; 2000 Jun; 26(6):679-85. PubMed ID: 10945383
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Non-invasive measurement of cardiac output: whole-body impedance cardiography in simultaneous comparison with thermodilution and direct oxygen Fick methods.
    Kööbi T; Kaukinen S; Ahola T; Turjanmaa VM
    Intensive Care Med; 1997 Nov; 23(11):1132-7. PubMed ID: 9434918
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Noninvasive assessment of cardiac output using thoracic electrical bioimpedance in hemodynamically stable and unstable patients after cardiac surgery: a comparison with pulmonary artery thermodilution.
    Suttner S; Schöllhorn T; Boldt J; Mayer J; Röhm KD; Lang K; Piper SN
    Intensive Care Med; 2006 Dec; 32(12):2053-8. PubMed ID: 17039348
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.