These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

506 related articles for article (PubMed ID: 17762472)

  • 41. Anterior and posterior internal fixation of vertical shear fractures of the pelvis.
    Stocks GW; Gabel GT; Noble PC; Hanson GW; Tullos HS
    J Orthop Res; 1991 Mar; 9(2):237-45. PubMed ID: 1992074
    [TBL] [Abstract][Full Text] [Related]  

  • 42. The antishock iliosacral screw.
    Gardner MJ; Chip Routt ML
    J Orthop Trauma; 2010 Oct; 24(10):e86-9. PubMed ID: 20871242
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Immediate percutaneous sacroiliac screw insertion for unstable pelvic fractures: is it safe enough?
    Acker A; Perry ZH; Blum S; Shaked G; Korngreen A
    Eur J Trauma Emerg Surg; 2018 Apr; 44(2):163-169. PubMed ID: 26972292
    [TBL] [Abstract][Full Text] [Related]  

  • 44. The T-pod is as stable as supraacetabular fixation using 1 or 2 Schanz screws in partially unstable pelvic fractures: a biomechanical study.
    Zeckey C; Cavalcanti Kußmaul A; Suero EM; Kammerlander C; Greiner A; Woiczinski M; Braun C; Flatz W; Boecker W; Becker CA
    Eur J Med Res; 2020 Jul; 25(1):26. PubMed ID: 32682448
    [TBL] [Abstract][Full Text] [Related]  

  • 45. [Treatment of old Tile B1 pelvic fracture by staged pelvic closure using external fixator combined with reconstruction plate].
    Tian Y; Fu Q
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2008 Mar; 22(3):324-7. PubMed ID: 18396713
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Mechanical testing of seven fixation methods for generation of compression across a midtarsal osteotomy: a comparison of internal and external fixation devices.
    Grant WP; Rubin LG; Pupp GR; Vito G; Jacobus D; Jerlin EA; Tam HS
    J Foot Ankle Surg; 2007; 46(5):325-35. PubMed ID: 17761316
    [TBL] [Abstract][Full Text] [Related]  

  • 47. [Stabilizing the pelvic ring with the external fixator. Biomechanical studies and clinical experiences].
    Egbers HJ; Draijer F; Havemann D; Zenker W
    Orthopade; 1992 Nov; 21(6):363-72. PubMed ID: 1475122
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Biomechanical testing of a concept of posterior pelvic reconstruction in rotationally and vertically unstable fractures.
    Berber O; Amis AA; Day AC
    J Bone Joint Surg Br; 2011 Feb; 93(2):237-44. PubMed ID: 21282765
    [TBL] [Abstract][Full Text] [Related]  

  • 49. [Percutaneous fixation of pelvic ring disruptions].
    Guo XS; Chi YL
    Zhonghua Wai Ke Za Zhi; 2006 Feb; 44(4):260-3. PubMed ID: 16635372
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Transcondylar traction as a closed reduction technique in vertically unstable pelvic ring disruption.
    Thaunat M; Laude F; Paillard P; Saillant G; Catonné Y
    Int Orthop; 2008 Feb; 32(1):7-12. PubMed ID: 17245603
    [TBL] [Abstract][Full Text] [Related]  

  • 51. The value of external fixation for unstable pelvic ring injuries.
    Galois L; Pfeffer F; Mainard D; Delagoutte JP
    Acta Orthop Belg; 2003 Aug; 69(4):321-7. PubMed ID: 14526636
    [TBL] [Abstract][Full Text] [Related]  

  • 52. [Sacroiliac fixation: a new technique after pelvic trauma].
    Hoffmann E; Levassor N; Rillardon L; Lavelle G; Guigui P
    Rev Chir Orthop Reparatrice Appar Mot; 2003 Dec; 89(8):725-9. PubMed ID: 14726839
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Anatomically correct reduction and fixation of a Tile C-1 type unilateral sacroiliac disruption using a rod and pedicle screw system between the S1 vertebra and the ilium: experimental and clinical case report.
    Saiki K; Hirabayashi S; Horie T; Tsuzuki N; Inokuchi K; Tsutsumi H
    J Orthop Sci; 2002; 7(5):581-6. PubMed ID: 12355135
    [TBL] [Abstract][Full Text] [Related]  

  • 54. [Pelvic girdle fractures--must they be stabilized?].
    Euler E; Krueger P; Betz A; Schweiberer L
    Unfallchirurg; 1992 Apr; 95(4):174-80. PubMed ID: 1636097
    [TBL] [Abstract][Full Text] [Related]  

  • 55. [Biomechanical effect of the iliac screw insertion depth on lumbo-iliac fixation construct].
    Chen H; Yu BS; Zheng ZM; Lü Y; Zhang KB; Liu H; Li FB
    Zhonghua Wai Ke Za Zhi; 2008 Aug; 46(15):1179-82. PubMed ID: 19094686
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Anterior approach and stabilization of the disrupted sacroiliac joint.
    Simpson LA; Waddell JP; Leighton RK; Kellam JF; Tile M
    J Trauma; 1987 Dec; 27(12):1332-9. PubMed ID: 3694724
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Fixation of the femoral condyles: a mechanical comparison of small and large fragment screw fixation.
    Khalafi A; Hazelwood S; Curtiss S; Wolinsky P
    J Trauma; 2008 Mar; 64(3):740-4. PubMed ID: 18332817
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Strength of the pin-bone interface of external fixation pins in the iliac crest. A biomechanical study.
    Liu J; Lai KA; Chou YL
    Clin Orthop Relat Res; 1995 Jan; (310):237-44. PubMed ID: 7641445
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Effectiveness and complications of primary C-clamp stabilization or external fixation for unstable pelvic fractures.
    Schmal H; Larsen MS; Stuby F; Strohm PC; Reising K; Goodwin Burri K
    Injury; 2019 Nov; 50(11):1959-1965. PubMed ID: 31477239
    [TBL] [Abstract][Full Text] [Related]  

  • 60. External fixation of unstable pelvic fractures: experiences in 22 patients treated with a trapezoid compression frame.
    Slätis P; Karaharju EO
    Clin Orthop Relat Res; 1980 Sep; (151):73-80. PubMed ID: 7418326
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 26.