BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

550 related articles for article (PubMed ID: 17762937)

  • 1. Thermal osteonecrosis and bone drilling parameters revisited.
    Augustin G; Davila S; Mihoci K; Udiljak T; Vedrina DS; Antabak A
    Arch Orthop Trauma Surg; 2008 Jan; 128(1):71-7. PubMed ID: 17762937
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Determination of spatial distribution of increase in bone temperature during drilling by infrared thermography: preliminary report.
    Augustin G; Davila S; Udiljak T; Vedrina DS; Bagatin D
    Arch Orthop Trauma Surg; 2009 May; 129(5):703-9. PubMed ID: 18421465
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Temperature changes during cortical bone drilling with a newly designed step drill and an internally cooled drill.
    Augustin G; Davila S; Udilljak T; Staroveski T; Brezak D; Babic S
    Int Orthop; 2012 Jul; 36(7):1449-56. PubMed ID: 22290154
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Heat production by 3 implant drill systems after repeated drilling and sterilization.
    Chacon GE; Bower DL; Larsen PE; McGlumphy EA; Beck FM
    J Oral Maxillofac Surg; 2006 Feb; 64(2):265-9. PubMed ID: 16413899
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Heat generation during implant site preparation: an in vitro study.
    Cordioli G; Majzoub Z
    Int J Oral Maxillofac Implants; 1997; 12(2):186-93. PubMed ID: 9109268
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Cortical bone drilling and thermal osteonecrosis.
    Augustin G; Zigman T; Davila S; Udilljak T; Staroveski T; Brezak D; Babic S
    Clin Biomech (Bristol); 2012 May; 27(4):313-25. PubMed ID: 22071428
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effects of irrigation temperature on heat control in vitro at different drilling depths.
    Sener BC; Dergin G; Gursoy B; Kelesoglu E; Slih I
    Clin Oral Implants Res; 2009 Mar; 20(3):294-8. PubMed ID: 19397641
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [An experimental verification of the thermal changes in the bone tissue during drilling for cavity preparation for an endosseous implant].
    Fagnoni V; Fontolan D; Polastri F; Zucca M
    Minerva Stomatol; 1991; 40(1-2):9-13. PubMed ID: 2041537
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of feed rate and drill speed on temperatures in equine cortical bone.
    Toews AR; Bailey JV; Townsend HG; Barber SM
    Am J Vet Res; 1999 Aug; 60(8):942-4. PubMed ID: 10451201
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The effect of speed, pressure, and time on bone temperature during the drilling of implant sites.
    Brisman DL
    Int J Oral Maxillofac Implants; 1996; 11(1):35-7. PubMed ID: 8820120
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Thermal changes and drill wear in bovine bone during implant site preparation. A comparative in vitro study: twisted stainless steel and ceramic drills.
    Oliveira N; Alaejos-Algarra F; Mareque-Bueno J; Ferrés-Padró E; Hernández-Alfaro F
    Clin Oral Implants Res; 2012 Aug; 23(8):963-9. PubMed ID: 21806686
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of surgical drill guide on heat generated from implant drilling.
    Misir AF; Sumer M; Yenisey M; Ergioglu E
    J Oral Maxillofac Surg; 2009 Dec; 67(12):2663-8. PubMed ID: 19925988
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Temperature rise during drilling through bone.
    Abouzgia MB; James DF
    Int J Oral Maxillofac Implants; 1997; 12(3):342-53. PubMed ID: 9197099
    [TBL] [Abstract][Full Text] [Related]  

  • 14. In-vitro experimental analysis and numerical study of temperature in bone drilling.
    Alam K; Khan M; Muhammad R; Qamar SZ; Silberschmidt VV
    Technol Health Care; 2015; 23(6):775-83. PubMed ID: 26409522
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Slow drilling speeds for single-drill implant bed preparation. Experimental in vitro study.
    Delgado-Ruiz RA; Velasco Ortega E; Romanos GE; Gerhke S; Newen I; Calvo-Guirado JL
    Clin Oral Investig; 2018 Jan; 22(1):349-359. PubMed ID: 28434045
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Heat distribution in bone during preparation of implant sites: heat analysis by real-time thermography.
    Watanabe F; Tawada Y; Komatsu S; Hata Y
    Int J Oral Maxillofac Implants; 1992; 7(2):212-9. PubMed ID: 1398838
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Rotary ultrasonic drilling on bone: A novel technique to put an end to thermal injury to bone.
    Gupta V; Pandey PM; Gupta RK; Mridha AR
    Proc Inst Mech Eng H; 2017 Mar; 231(3):189-196. PubMed ID: 28116985
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Osteotomy irrigation: is it necessary?
    Flanagan D
    Implant Dent; 2010 Jun; 19(3):241-9. PubMed ID: 20523180
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Influence of bone density, drill diameter, drilling speed, and irrigation on temperature changes during implant osteotomies: an in vitro study.
    Salomó-Coll O; Auriol-Muerza B; Lozano-Carrascal N; Hernández-Alfaro F; Wang HL; Gargallo-Albiol J
    Clin Oral Investig; 2021 Mar; 25(3):1047-1053. PubMed ID: 32533265
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Thermal effects of various drill materials during implant site preparation-Ceramic vs. stainless steel drills: A comparative in vitro study in a standardised bovine bone model.
    Tur D; Giannis K; Unger E; Mittlböck M; Rausch-Fan X; Strbac GD
    Clin Oral Implants Res; 2021 Feb; 32(2):154-166. PubMed ID: 33220104
    [TBL] [Abstract][Full Text] [Related]  