BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

306 related articles for article (PubMed ID: 17763842)

  • 1. Accuracy of bedside capillary blood glucose measurements in critically ill patients.
    Critchell CD; Savarese V; Callahan A; Aboud C; Jabbour S; Marik P
    Intensive Care Med; 2007 Dec; 33(12):2079-84. PubMed ID: 17763842
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Inaccuracy of Venous Point-of-Care Glucose Measurements in Critically Ill Patients: A Cross-Sectional Study.
    Pereira AJ; CorrĂȘa TD; de Almeida FP; Deliberato RO; Lobato Mdos S; Akamine N; Silva E; Cavalcanti AB
    PLoS One; 2015; 10(6):e0129568. PubMed ID: 26067093
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Bedside capillary blood glucose measurements in critically ill patients: influence of catecholamine therapy.
    Fekih Hassen M; Ayed S; Gharbi R; Ben Sik Ali H; Marghli S; Elatrous S
    Diabetes Res Clin Pract; 2010 Jan; 87(1):87-91. PubMed ID: 19853946
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Accuracy of AccuChek glucose measurement in intensive care patients.
    Meynaar IA; van Spreuwel M; Tangkau PL; Dawson L; Sleeswijk Visser S; Rijks L; Vlieland TV
    Crit Care Med; 2009 Oct; 37(10):2691-6. PubMed ID: 19885987
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of bedside and laboratory blood glucose estimations in critically ill children with shock.
    Ramachandran B; Sethuraman R; Ravikumar KG; Kissoon N
    Pediatr Crit Care Med; 2011 Nov; 12(6):e297-301. PubMed ID: 21478799
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Evaluation of accuracy and influence factors of bedside blood glucose monitoring in critically ill patients].
    Feng T; Cao XY
    Zhongguo Wei Zhong Bing Ji Jiu Yi Xue; 2012 Aug; 24(8):482-6. PubMed ID: 22871408
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of point-of-care and laboratory glucose analysis in critically ill patients.
    Lacara T; Domagtoy C; Lickliter D; Quattrocchi K; Snipes L; Kuszaj J; Prasnikar M
    Am J Crit Care; 2007 Jul; 16(4):336-46; quiz 347. PubMed ID: 17595363
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of POCT and central laboratory blood glucose results using arterial, capillary, and venous samples from MICU patients on a tight glycemic protocol.
    Petersen JR; Graves DF; Tacker DH; Okorodudu AO; Mohammad AA; Cardenas VJ
    Clin Chim Acta; 2008 Oct; 396(1-2):10-3. PubMed ID: 18606159
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Reliability of point-of-care testing for glucose measurement in critically ill adults.
    Kanji S; Buffie J; Hutton B; Bunting PS; Singh A; McDonald K; Fergusson D; McIntyre LA; Hebert PC
    Crit Care Med; 2005 Dec; 33(12):2778-85. PubMed ID: 16352960
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy of Point-of-Care Blood Glucose Level Measurements in Critically Ill Patients with Sepsis Receiving High-Dose Intravenous Vitamin C.
    Smith KE; Brown CS; Manning BM; May T; Riker RR; Lerwick PA; Hayes TL; Fraser GL
    Pharmacotherapy; 2018 Nov; 38(11):1155-1161. PubMed ID: 30230568
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of glucose point-of-care values with laboratory values in critically ill patients.
    Shearer A; Boehmer M; Closs M; Dela Rosa R; Hamilton J; Horton K; McGrath R; Schulman C
    Am J Crit Care; 2009 May; 18(3):224-30. PubMed ID: 19411582
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Use of arterial blood with bedside glucose reflectance meters in an intensive care unit: are they accurate?
    Maser RE; Butler MA; DeCherney GS
    Crit Care Med; 1994 Apr; 22(4):595-9. PubMed ID: 8143469
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Accuracy and feasibility of point-of-care and continuous blood glucose analysis in critically ill ICU patients.
    Corstjens AM; Ligtenberg JJ; van der Horst IC; Spanjersberg R; Lind JS; Tulleken JE; Meertens JH; Zijlstra JG
    Crit Care; 2006; 10(5):R135. PubMed ID: 16981981
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accuracy of bedside glucose measurement from three glucometers in critically ill patients.
    Hoedemaekers CW; Klein Gunnewiek JM; Prinsen MA; Willems JL; Van der Hoeven JG
    Crit Care Med; 2008 Nov; 36(11):3062-6. PubMed ID: 18824915
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Analysis of blood glucose measurements using capillary and arterial blood samples in intensive care patients.
    Kulkarni A; Saxena M; Price G; O'Leary MJ; Jacques T; Myburgh JA
    Intensive Care Med; 2005 Jan; 31(1):142-5. PubMed ID: 15565362
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Differences in glucose values obtained from point-of-care glucose meters and laboratory analysis in critically ill patients.
    Cook A; Laughlin D; Moore M; North D; Wilkins K; Wong G; Wallace-Scroggs A; Halvorsen L
    Am J Crit Care; 2009 Jan; 18(1):65-71; quiz 72. PubMed ID: 19116407
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Fingerstick glucose determination in shock.
    Atkin SH; Dasmahapatra A; Jaker MA; Chorost MI; Reddy S
    Ann Intern Med; 1991 Jun; 114(12):1020-4. PubMed ID: 2029097
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The performance of flash glucose monitoring in critically ill patients with diabetes.
    Ancona P; Eastwood GM; Lucchetta L; Ekinci EI; Bellomo R; MĂ„rtensson J
    Crit Care Resusc; 2017 Jun; 19(2):167-174. PubMed ID: 28651513
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Relative accuracy of arterial and capillary glucose meter measurements in critically ill patients.
    Lonjaret L; Claverie V; Berard E; Riu-Poulenc B; Geeraerts T; Genestal M; Fourcade O
    Diabetes Metab; 2012 Jun; 38(3):230-5. PubMed ID: 22342294
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Point-of-Care Versus Central Laboratory Measurements of Hemoglobin, Hematocrit, Glucose, Bicarbonate and Electrolytes: A Prospective Observational Study in Critically Ill Patients.
    Allardet-Servent J; Lebsir M; Dubroca C; Fabrigoule M; Jordana S; Signouret T; Castanier M; Thomas G; Soundaravelou R; Lepidi A; Delapierre L; Penaranda G; Halfon P; Seghboyan JM
    PLoS One; 2017; 12(1):e0169593. PubMed ID: 28072822
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.