These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

221 related articles for article (PubMed ID: 17764456)

  • 1. Accuracy in ECG lead placement among technicians, nurses, general physicians and cardiologists.
    Rajaganeshan R; Ludlam CL; Francis DP; Parasramka SV; Sutton R
    Int J Clin Pract; 2008 Jan; 62(1):65-70. PubMed ID: 17764456
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of p-wave patterns derived from correct and incorrect placement of V1-V2 electrodes.
    García-Niebla J
    J Cardiovasc Nurs; 2009; 24(2):156-61. PubMed ID: 19242281
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Accuracy of ECG electrode placement by emergency department clinicians.
    McCann K; Holdgate A; Mahammad R; Waddington A
    Emerg Med Australas; 2007 Oct; 19(5):442-8. PubMed ID: 17919217
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Changes in electrocardiogram in V1 by precordial electrode malposition].
    Koehler NR
    Arq Bras Cardiol; 1993 Aug; 61(2):99-101. PubMed ID: 8297229
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Placement of cardiac electrodes: written, simulated, and actual accuracy.
    Bupp JE; Dinger M; Lawrence C; Wingate S
    Am J Crit Care; 1997 Nov; 6(6):457-62. PubMed ID: 9354224
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy in precordial ECG lead placement: Improving performance through a peer-led educational intervention.
    Medani SA; Hensey M; Caples N; Owens P
    J Electrocardiol; 2018; 51(1):50-54. PubMed ID: 28576322
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The effects of electrode misplacement on clinicians' interpretation of the standard 12-lead electrocardiogram.
    Bond RR; Finlay DD; Nugent CD; Breen C; Guldenring D; Daly MJ
    Eur J Intern Med; 2012 Oct; 23(7):610-5. PubMed ID: 22939805
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Posterior myocardial infarction: are we failing to diagnose this?
    Khan JN; Chauhan A; Mozdiak E; Khan JM; Varma C
    Emerg Med J; 2012 Jan; 29(1):15-8. PubMed ID: 20961938
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Proposed bedside maneuver to facilitate accurate anatomic orientation for correct positioning of ECG precordial leads V1 and V2: a pilot study.
    Lehmann MH; Katona AM
    J Emerg Med; 2012 Oct; 43(4):584-92. PubMed ID: 22504082
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A simple measure to control for variations in chest electrodes placement in serial electrocardiogram recordings.
    Soliman EZ
    J Electrocardiol; 2008; 41(5):378-9. PubMed ID: 18620704
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Human factors analysis of the CardioQuick Patch®: A novel engineering solution to the problem of electrode misplacement during 12-lead electrocardiogram acquisition.
    Bond RR; Finlay DD; McLaughlin J; Guldenring D; Cairns A; Kennedy A; Deans R; Waldo AL; Peace A
    J Electrocardiol; 2016; 49(6):911-918. PubMed ID: 27662775
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Precordial low voltage in patients with ascites.
    Cuculi F; Jamshidi P; Kobza R; Rohacek M; Erne P
    Europace; 2008 Jan; 10(1):96-8. PubMed ID: 18003635
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effects of limb electrode placement on the 12- and 16-lead electrocardiogram.
    Farrell RM; Syed A; Syed A; Gutterman DD
    J Electrocardiol; 2008; 41(6):536-45. PubMed ID: 18790505
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Variability of electrocardiographic precordial lead placement: a method to improve accuracy and reliability.
    Herman MV; Ingram DA; Levy JA; Cook JR; Athans RJ
    Clin Cardiol; 1991 Jun; 14(6):469-76. PubMed ID: 1810683
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Adherence to guidelines when positioning the defibrillation electrodes.
    Nurmi J; Rosenberg P; Castrén M
    Resuscitation; 2004 May; 61(2):143-7. PubMed ID: 15135190
    [TBL] [Abstract][Full Text] [Related]  

  • 16. On designing and testing transformations for derivation of standard 12-lead/18-lead electrocardiograms and vectorcardiograms from reduced sets of predictor leads.
    Horácek BM; Warren JW; Wang JJ
    J Electrocardiol; 2008; 41(3):220-9. PubMed ID: 18433613
    [TBL] [Abstract][Full Text] [Related]  

  • 17. 12-lead ECG training: the way forward.
    Alinier G; Gordon R; Harwood C; Hunt WB
    Nurse Educ Today; 2006 Jan; 26(1):87-92. PubMed ID: 16182413
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Do junior doctors know where to insert chest drains safely?
    Griffiths JR; Roberts N
    Postgrad Med J; 2005 Jul; 81(957):456-8. PubMed ID: 15998822
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Analysis of the effects of the continuous electrode paste band on precordial leads of the electrocardiogram.
    Petterson CH; Koehler NR; Passos R; Christmann I
    Arq Bras Cardiol; 1999 Sep; 73(3):259-72. PubMed ID: 10752165
    [TBL] [Abstract][Full Text] [Related]  

  • 20. How many electrodes and where? A "poldermodel" for electrocardiography.
    Kors JA; van Herpen G
    J Electrocardiol; 2002; 35 Suppl():7-12. PubMed ID: 12539094
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.