These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

186 related articles for article (PubMed ID: 1777770)

  • 1. Noninvasive measurement of arterial oxyhemoglobin saturation with a heated and a non-heated skin reflectance pulse oximeter sensor.
    Mendelson Y; Yocum BL
    Biomed Instrum Technol; 1991; 25(6):472-80. PubMed ID: 1777770
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The feasibility of spectrophotometric measurements of arterial oxygen saturation from the fetal scalp utilizing noninvasive skin-reflectance pulse oximetry.
    Mendelson Y; Solomita MV
    Biomed Instrum Technol; 1992; 26(3):215-24. PubMed ID: 1596651
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Skin reflectance pulse oximetry: in vivo measurements from the forearm and calf.
    Mendelson Y; McGinn MJ
    J Clin Monit; 1991 Jan; 7(1):7-12. PubMed ID: 1999702
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Experimental and clinical evaluation of a noninvasive reflectance pulse oximeter sensor.
    Takatani S; Davies C; Sakakibara N; Zurick A; Kraenzler E; Golding LR; Noon GP; Nose Y; DeBakey ME
    J Clin Monit; 1992 Oct; 8(4):257-66. PubMed ID: 1453185
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Design and evaluation of a new reflectance pulse oximeter sensor.
    Mendelson Y; Kent JC; Yocum BL; Birle MJ
    Med Instrum; 1988 Aug; 22(4):167-73. PubMed ID: 3173170
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Validation of reflectance pulse oximetry: an evaluation of a new sensor in piglets.
    Nijland R; Nierlich S; Jongsma HW; Nijhuis JG; Oeseburg B; Springer K; Mannheimer P
    J Clin Monit; 1997 Jan; 13(1):43-9. PubMed ID: 9058252
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Transmission pulse oximetry in the fetal lamb: is there a universal calibration?
    Nijland R; Jongsma HW; Crevels J; Menssen JJ; Nijhuis JG; Oeseburg B
    Pediatr Res; 1996 Mar; 39(3):464-9. PubMed ID: 8929867
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Accuracy and utility of a new reflectance pulse oximeter for fetal monitoring during labor.
    Izumi A; Minakami H; Sato I
    J Clin Monit; 1997 Mar; 13(2):103-8. PubMed ID: 9112205
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Simultaneous comparison of three noninvasive oximeters in healthy volunteers.
    Mendelson Y; Kent JC; Shahnarian A; Welch GW; Giasi RM
    Med Instrum; 1987 Jun; 21(3):183-8. PubMed ID: 3614041
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Noninvasive oximetry in the rat.
    Decker MJ; Conrad KP; Strohl KP
    Biomed Instrum Technol; 1989; 23(3):222-8. PubMed ID: 2752232
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Accuracy of pulse oximetry to estimate HbO2 fraction of total Hb during exercise.
    Powers SK; Dodd S; Freeman J; Ayers GD; Samson H; McKnight T
    J Appl Physiol (1985); 1989 Jul; 67(1):300-4. PubMed ID: 2759956
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Accuracy of noninvasive oxyhemoglobin saturation, end-tidal carbon dioxide concentration, and blood pressure monitoring during experimentally induced hypoxemia, hypotension, or hypertension in anesthetized dogs.
    Grosenbaugh DA; Muir WW
    Am J Vet Res; 1998 Feb; 59(2):205-12. PubMed ID: 9492938
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Pulse oximetry in very low birth weight infants with acute and chronic lung disease.
    Ramanathan R; Durand M; Larrazabal C
    Pediatrics; 1987 Apr; 79(4):612-7. PubMed ID: 2434913
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accuracy of pulse oximetry during arterial oxyhemoglobin desaturation in dogs.
    Sendak MJ; Harris AP; Donham RT
    Anesthesiology; 1988 Jan; 68(1):111-4. PubMed ID: 3337361
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dark skin decreases the accuracy of pulse oximeters at low oxygen saturation: the effects of oximeter probe type and gender.
    Feiner JR; Severinghaus JW; Bickler PE
    Anesth Analg; 2007 Dec; 105(6 Suppl):S18-S23. PubMed ID: 18048893
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The effect of sensor malpositioning on pulse oximeter accuracy during hypoxemia.
    Barker SJ; Hyatt J; Shah NK; Kao YJ
    Anesthesiology; 1993 Aug; 79(2):248-54. PubMed ID: 8342837
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Clinical investigation of a new combined pulse oximetry and carbon dioxide tension sensor in adult anaesthesia.
    Rohling R; Biro P
    J Clin Monit Comput; 1999 Jan; 15(1):23-7. PubMed ID: 12578058
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Accuracy of calculated arterial saturation in oxygen in neonatal foals and effects of monitor, sensor, site of sensor placement, and degree of hypoxemia on the accuracy of pulse oximetry.
    Giguère S; Sanchez LC; Shih A
    J Vet Emerg Crit Care (San Antonio); 2014; 24(5):529-35. PubMed ID: 25212699
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Accuracy of a pulse oximeter during hypoxia].
    Tachibana C; Fukada T; Hasegawa R; Satoh K; Furuya Y; Ohe Y
    Masui; 1996 Apr; 45(4):479-82. PubMed ID: 8725606
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pulse oximeter performance during desaturation and resaturation: a comparison of seven models.
    Trivedi NS; Ghouri AF; Lai E; Shah NK; Barker SJ
    J Clin Anesth; 1997 May; 9(3):184-8. PubMed ID: 9172023
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.