These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
161 related articles for article (PubMed ID: 17804874)
1. Four-dimensional magnetic resonance imaging for the determination of tumour movement and its evaluation using a dynamic porcine lung phantom. Remmert G; Biederer J; Lohberger F; Fabel M; Hartmann GH Phys Med Biol; 2007 Sep; 52(18):N401-15. PubMed ID: 17804874 [TBL] [Abstract][Full Text] [Related]
2. Correcting bulk in-plane motion artifacts in MRI using the point spread function. Lin W; Wehrli FW; Song HK IEEE Trans Med Imaging; 2005 Sep; 24(9):1170-6. PubMed ID: 16156354 [TBL] [Abstract][Full Text] [Related]
3. Motion-compensated MR valve imaging with COMB tag tracking and super-resolution enhancement. Dowsey AW; Keegan J; Lerotic M; Thom S; Firmin D; Yang GZ Med Image Anal; 2007 Oct; 11(5):478-91. PubMed ID: 17804277 [TBL] [Abstract][Full Text] [Related]
4. Computation of transmitted and received B1 fields in magnetic resonance imaging. Milles J; Zhu YM; Chen NK; Panych LP; Gimenez G; Guttmann CR IEEE Trans Biomed Eng; 2006 May; 53(5):885-95. PubMed ID: 16686411 [TBL] [Abstract][Full Text] [Related]
5. Dynamic contrast-enhanced magnetic resonance images of the kidney. Lv D; Zhuang J; Chen H; Wang J; Xu Y; Yang X; Zhang J; Wang X; Fang J IEEE Eng Med Biol Mag; 2008; 27(5):36-41. PubMed ID: 18799388 [No Abstract] [Full Text] [Related]
7. Correction of motion artifacts from cardiac cine magnetic resonance images. Lötjönen J; Pollari M; Kivistö S; Lauerma K Acad Radiol; 2005 Oct; 12(10):1273-84. PubMed ID: 16179204 [TBL] [Abstract][Full Text] [Related]
8. Manifold learning for image-based breathing gating in ultrasound and MRI. Wachinger C; Yigitsoy M; Rijkhorst EJ; Navab N Med Image Anal; 2012 May; 16(4):806-18. PubMed ID: 22226466 [TBL] [Abstract][Full Text] [Related]
9. Detection and measurement of coverage loss in interleaved multi-acquisition brain MRIs due to motion-induced inter-slice misalignment. Tam RC; Riddehough A; Li DK Med Image Anal; 2009 Jun; 13(3):381-91. PubMed ID: 19200772 [TBL] [Abstract][Full Text] [Related]
15. In vivo MR-tracking based on magnetic signature selective excitation. Felfoul O; Mathieu JB; Beaudoin G; Martel S IEEE Trans Med Imaging; 2008 Jan; 27(1):28-35. PubMed ID: 18270059 [TBL] [Abstract][Full Text] [Related]
16. Automated phase correction via maximization of the real signal. Hardy EH; Hoferer J; Mertens D; Kasper G Magn Reson Imaging; 2009 Apr; 27(3):393-400. PubMed ID: 18760554 [TBL] [Abstract][Full Text] [Related]
17. Correction of left ventricular wall thickening from short-axis cine MRI for basal-descent through-plane motion. Chai JW; Chen WH; Chen HM; Chiang CM; Huang JL; Fu J; Chi-Chang Chen C; Lee SK J Magn Reson Imaging; 2011 Feb; 33(2):464-73. PubMed ID: 21274990 [TBL] [Abstract][Full Text] [Related]
18. Surface modeling--uncertainty estimation and visualization. Drapikowski P Comput Med Imaging Graph; 2008 Mar; 32(2):134-9. PubMed ID: 18082372 [TBL] [Abstract][Full Text] [Related]
20. 4D MR imaging of respiratory organ motion and its variability. von Siebenthal M; Székely G; Gamper U; Boesiger P; Lomax A; Cattin P Phys Med Biol; 2007 Mar; 52(6):1547-64. PubMed ID: 17327648 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]