These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

99 related articles for article (PubMed ID: 17805388)

  • 1. High-accuracy differential image motion monitor measurements for the Thirty Meter Telescope site testing program.
    Wang L; Schöck M; Chanan G; Skidmore W; Blum R; Bustos E; Els S; Riddle R; Seguel J; Travouillon T; Vasquez J; Walker D; Gillett P
    Appl Opt; 2007 Sep; 46(25):6460-8. PubMed ID: 17805388
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Study on the precision of the multiaperture scintillation sensor turbulence profiler (MASS) employed in the site testing campaign for the Thirty Meter Telescope.
    Els SG; Schöck M; Seguel J; Tokovinin A; Kornilov V; Riddle R; Skidmore W; Travouillon T; Vogiatzis K; Blum R; Bustos E; Gregory B; Vasquez J; Walker D; Gillett P
    Appl Opt; 2008 May; 47(14):2610-8. PubMed ID: 18470256
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Numerical simulation of a large area scintillometer and laser differential image motion monitor.
    Brown DM; Hanna RT; Brown AM; Hixson JG; Baldwin KC
    Appl Opt; 2022 Jan; 61(1):10-21. PubMed ID: 35200796
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Quality-control issues on high-resolution diagnostic monitors.
    Parr LF; Anderson AL; Glennon BK; Fetherston P
    J Digit Imaging; 2001 Jun; 14(2 Suppl 1):22-6. PubMed ID: 11442103
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Night-time measurements of astronomical seeing at Dome A in Antarctica.
    Ma B; Shang Z; Hu Y; Hu K; Wang Y; Yang X; Ashley MCB; Hickson P; Jiang P
    Nature; 2020 Jul; 583(7818):771-774. PubMed ID: 32728236
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Feasibility studies for the alignment of the Thirty Meter Telescope.
    Zimmerman DC
    Appl Opt; 2010 Jun; 49(18):3485-98. PubMed ID: 20563201
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Multiwavelength differential image motion monitor.
    Neimeier D; Oesch D; Andrews J; Baca J; Teare S
    Opt Express; 2002 Jul; 10(13):561-5. PubMed ID: 19436398
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The assessment and characterization of the built-in internal photometer of primary diagnostic monitors.
    Ruuge AE; Mahmood UA; Erdi YE
    J Appl Clin Med Phys; 2017 Mar; 18(2):170-175. PubMed ID: 28300388
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Determination of the optical turbulence parameters from the adaptive optics telemetry: critical analysis and on-sky validation.
    Jolissaint L; Ragland S; Christou J; Wizinowich P
    Appl Opt; 2018 Sep; 57(27):7837-7856. PubMed ID: 30462050
    [TBL] [Abstract][Full Text] [Related]  

  • 10. An infrared system for monitoring Drosophila motility during microgravity.
    Miller MS; Fortney MD; Keller TS
    J Gravit Physiol; 2002 Dec; 9(2):83-91. PubMed ID: 14638462
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Review of measurement methods and clinical validation studies of noninvasive blood pressure monitors: accuracy requirements and protocol considerations for devices that require patient-specific calibration by a secondary method or device before use.
    Ng KG
    Blood Press Monit; 2011 Dec; 16(6):291-303. PubMed ID: 22064634
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A photoelectric focus and seeing monitor for solar telescopes.
    Beckers JM
    Appl Opt; 1966 Feb; 5(2):301-4. PubMed ID: 20048835
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of measurements of the outer scale of turbulence by three different techniques.
    Ziad A; Schöck M; Chanan GA; Troy M; Dekany R; Lane BF; Borgnino J; Martin F
    Appl Opt; 2004 Apr; 43(11):2316-24. PubMed ID: 15098834
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Estimation of the GSSM calibration error.
    Han L; Zhang J; Yang F; An Q
    Appl Opt; 2016 Nov; 55(31):8884-8892. PubMed ID: 27828290
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The Optical Design of the 40-in. Telescope and of the Irenee DuPont Telescope at Las Campanas Observatory, Chile.
    Bowen IS; Vaughan AH
    Appl Opt; 1973 Jul; 12(7):1430-4. PubMed ID: 20125543
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Laser frequency combs for astronomical observations.
    Steinmetz T; Wilken T; Araujo-Hauck C; Holzwarth R; Hänsch TW; Pasquini L; Manescau A; D'Odorico S; Murphy MT; Kentischer T; Schmidt W; Udem T
    Science; 2008 Sep; 321(5894):1335-7. PubMed ID: 18772434
    [TBL] [Abstract][Full Text] [Related]  

  • 17. First fringe measurements with a phase-tracking stellar interferometer.
    Shao M; Staelin DH
    Appl Opt; 1980 May; 19(9):1519-22. PubMed ID: 20221067
    [TBL] [Abstract][Full Text] [Related]  

  • 18. From the grating scale monitor to the generalized seeing monitor.
    Ziad A; Conan R; Tokovinin A; Martin F; Borgnino J
    Appl Opt; 2000 Oct; 39(30):5415-25. PubMed ID: 18354538
    [TBL] [Abstract][Full Text] [Related]  

  • 19. SU-E-J-129: Target-Specific Optimization of Four-Dimensional Cone Beam Computed Tomography.
    Ahmad M; Pan T
    Med Phys; 2012 Jun; 39(6Part8):3682. PubMed ID: 28518924
    [TBL] [Abstract][Full Text] [Related]  

  • 20. SoftCopy Display Quality Assurance Program at Texas Children's Hospital.
    Ly CK
    J Digit Imaging; 2002; 15 Suppl 1():33-40. PubMed ID: 12105695
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.