BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

832 related articles for article (PubMed ID: 17822010)

  • 41. CT dose reduction using Automatic Exposure Control and iterative reconstruction: A chest paediatric phantoms study.
    Greffier J; Pereira F; Macri F; Beregi JP; Larbi A
    Phys Med; 2016 Apr; 32(4):582-9. PubMed ID: 27056436
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Characterization of radiation dose from tube current modulated CT examinations with considerations of both patient size and variable tube current.
    Li X; Yang K; Liu B
    Med Phys; 2017 Oct; 44(10):5413-5422. PubMed ID: 28681439
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Experimental assessment of the influence of beam hardening filters on image quality and patient dose in volumetric 64-slice X-ray CT scanners.
    Ay MR; Mehranian A; Maleki A; Ghadiri H; Ghafarian P; Zaidi H
    Phys Med; 2013 May; 29(3):249-60. PubMed ID: 22541061
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Automatic tube-current modulation in CT--a comparison between different solutions.
    Althén JN
    Radiat Prot Dosimetry; 2005; 114(1-3):308-12. PubMed ID: 15933127
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Relationships of clinical protocols and reconstruction kernels with image quality and radiation dose in a 128-slice CT scanner: study with an anthropomorphic and water phantom.
    Paul J; Krauss B; Banckwitz R; Maentele W; Bauer RW; Vogl TJ
    Eur J Radiol; 2012 May; 81(5):e699-703. PubMed ID: 21316888
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Effect of automatic tube voltage selection on image quality and radiation dose in abdominal CT angiography of various body sizes: a phantom study.
    Schindera ST; Winklehner A; Alkadhi H; Goetti R; Fischer M; Gnannt R; Szucs-Farkas Z
    Clin Radiol; 2013 Feb; 68(2):e79-86. PubMed ID: 23219454
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Characteristic image quality of a third generation dual-source MDCT scanner: Noise, resolution, and detectability.
    Solomon J; Wilson J; Samei E
    Med Phys; 2015 Aug; 42(8):4941-53. PubMed ID: 26233220
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Efficient use of automatic exposure control systems in computed tomography requires correct patient positioning.
    Gudjonsdottir J; Svensson JR; Campling S; Brennan PC; Jonsdottir B
    Acta Radiol; 2009 Nov; 50(9):1035-41. PubMed ID: 19863414
    [TBL] [Abstract][Full Text] [Related]  

  • 49. The relevance of image quality indices for dose optimization in abdominal multi-detector row CT in children: experimental assessment with pediatric phantoms.
    Brisse HJ; Brenot J; Pierrat N; Gaboriaud G; Savignoni A; De Rycke Y; Neuenschwander S; Aubert B; Rosenwald JC
    Phys Med Biol; 2009 Apr; 54(7):1871-92. PubMed ID: 19265204
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Dual-energy, standard and low-kVp contrast-enhanced CT-cholangiography: a comparative analysis of image quality and radiation exposure.
    Stiller W; Schwarzwaelder CB; Sommer CM; Veloza S; Radeleff BA; Kauczor HU
    Eur J Radiol; 2012 Jul; 81(7):1405-12. PubMed ID: 21458939
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Assessment of image quality on effects of varying tube voltage and automatic tube current modulation with hybrid and pure iterative reconstruction techniques in abdominal/pelvic CT: a phantom study.
    Vardhanabhuti V; Loader R; Roobottom CA
    Invest Radiol; 2013 Mar; 48(3):167-74. PubMed ID: 23344519
    [TBL] [Abstract][Full Text] [Related]  

  • 52. CT head-scan dosimetry in an anthropomorphic phantom and associated measurement of ACR accreditation-phantom imaging metrics under clinically representative scan conditions.
    Brunner CC; Stern SH; Minniti R; Parry MI; Skopec M; Chakrabarti K
    Med Phys; 2013 Aug; 40(8):081917. PubMed ID: 23927331
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Task-based assessment of neck CT protocols using patient-mimicking phantoms-effects of protocol parameters on dose and diagnostic performance.
    Jahnke P; Conzelmann J; Genske U; Nunninger M; Scheel M; Hamm B; Diekhoff T
    Eur Radiol; 2021 May; 31(5):3177-3186. PubMed ID: 33151393
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Evaluation of z-axis resolution and image noise for nonconstant velocity spiral CT data reconstructed using a weighted 3D filtered backprojection (WFBP) reconstruction algorithm.
    Christner JA; Stierstorfer K; Primak AN; Eusemann CD; Flohr TG; McCollough CH
    Med Phys; 2010 Feb; 37(2):897-906. PubMed ID: 20229899
    [TBL] [Abstract][Full Text] [Related]  

  • 55. A comparative study based on image quality and clinical task performance for CT reconstruction algorithms in radiotherapy.
    Li H; Dolly S; Chen HC; Anastasio MA; Low DA; Li HH; Michalski JM; Thorstad WL; Gay H; Mutic S
    J Appl Clin Med Phys; 2016 Jul; 17(4):377-390. PubMed ID: 27455472
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Quantitative Image Quality and Histogram-Based Evaluations of an Iterative Reconstruction Algorithm at Low-to-Ultralow Radiation Dose Levels: A Phantom Study in Chest CT.
    Lee KB; Goo HW
    Korean J Radiol; 2018; 19(1):119-129. PubMed ID: 29354008
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Automated low-kilovoltage selection in pediatric computed tomography angiography: phantom study evaluating effects on radiation dose and image quality.
    Siegel MJ; Ramirez-Giraldo JC; Hildebolt C; Bradley D; Schmidt B
    Invest Radiol; 2013 Aug; 48(8):584-9. PubMed ID: 23563195
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Preliminary results: prospective clinical study to assess image-based iterative reconstruction for abdominal computed tomography acquired at 2 radiation dose levels.
    Pourjabbar S; Singh S; Singh AK; Johnston RP; Shenoy-Bhangle AS; Do S; Padole A; Blake MA; Persson A; Kalra MK
    J Comput Assist Tomogr; 2014; 38(1):117-22. PubMed ID: 24424560
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm--initial clinical experience.
    Marin D; Nelson RC; Schindera ST; Richard S; Youngblood RS; Yoshizumi TT; Samei E
    Radiology; 2010 Jan; 254(1):145-53. PubMed ID: 20032149
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Comparison of Z-axis automatic tube current modulation technique with fixed tube current CT scanning of abdomen and pelvis.
    Kalra MK; Maher MM; Toth TL; Kamath RS; Halpern EF; Saini S
    Radiology; 2004 Aug; 232(2):347-53. PubMed ID: 15286306
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 42.