These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

264 related articles for article (PubMed ID: 17822013)

  • 1. Automatic segmentation of phase-correlated CT scans through nonrigid image registration using geometrically regularized free-form deformation.
    Shekhar R; Lei P; Castro-Pareja CR; Plishker WL; D'Souza WD
    Med Phys; 2007 Jul; 34(7):3054-66. PubMed ID: 17822013
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Quantifying the accuracy of automated structure segmentation in 4D CT images using a deformable image registration algorithm.
    Wijesooriya K; Weiss E; Dill V; Dong L; Mohan R; Joshi S; Keall PJ
    Med Phys; 2008 Apr; 35(4):1251-60. PubMed ID: 18491517
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Augmenting atlas-based liver segmentation for radiotherapy treatment planning by incorporating image features proximal to the atlas contours.
    Li D; Liu L; Chen J; Li H; Yin Y; Ibragimov B; Xing L
    Phys Med Biol; 2017 Jan; 62(1):272-288. PubMed ID: 27991439
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Simulation of four-dimensional CT images from deformable registration between inhale and exhale breath-hold CT scans.
    Sarrut D; Boldea V; Miguet S; Ginestet C
    Med Phys; 2006 Mar; 33(3):605-17. PubMed ID: 16878564
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Four-dimensional radiotherapy planning for DMLC-based respiratory motion tracking.
    Keall PJ; Joshi S; Vedam SS; Siebers JV; Kini VR; Mohan R
    Med Phys; 2005 Apr; 32(4):942-51. PubMed ID: 15895577
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Monte Carlo as a four-dimensional radiotherapy treatment-planning tool to account for respiratory motion.
    Keall PJ; Siebers JV; Joshi S; Mohan R
    Phys Med Biol; 2004 Aug; 49(16):3639-48. PubMed ID: 15446794
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Quantification of organ motion based on an adaptive image-based scale invariant feature method.
    Paganelli C; Peroni M; Baroni G; Riboldi M
    Med Phys; 2013 Nov; 40(11):111701. PubMed ID: 24320409
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Accurate CT∕MR vessel-guided nonrigid registration of largely deformed livers.
    Vasquez Osorio EM; Hoogeman MS; Mendez Romero A; Wielopolski P; Zolnay A; Heijmen BJ
    Med Phys; 2012 May; 39(5):2463-77. PubMed ID: 22559617
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Reconstruction of a time-averaged midposition CT scan for radiotherapy planning of lung cancer patients using deformable registration.
    Wolthaus JW; Sonke JJ; van Herk M; Damen EM
    Med Phys; 2008 Sep; 35(9):3998-4011. PubMed ID: 18841851
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A proposed framework for consensus-based lung tumour volume auto-segmentation in 4D computed tomography imaging.
    Martin S; Brophy M; Palma D; Louie AV; Yu E; Yaremko B; Ahmad B; Barron JL; Beauchemin SS; Rodrigues G; Gaede S
    Phys Med Biol; 2015 Feb; 60(4):1497-518. PubMed ID: 25611494
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The relative accuracy of 4D dose accumulation for lung radiotherapy using rigid dose projection versus dose recalculation on every breathing phase.
    Valdes G; Lee C; Tenn S; Lee P; Robinson C; Iwamoto K; Low D; Lamb JM
    Med Phys; 2017 Mar; 44(3):1120-1127. PubMed ID: 28019649
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Contour propagation for lung tumor delineation in 4D-CT using tensor-product surface of uniform and non-uniform closed cubic B-splines.
    Jin R; Liu Y; Chen M; Zhang S; Song E
    Phys Med Biol; 2017 Dec; 63(1):015017. PubMed ID: 29045239
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A fast 4D IMRT/VMAT planning method based on segment aperture morphing.
    Klawikowski S; Tai A; Ates O; Ahunbay E; Li XA
    Med Phys; 2018 Apr; 45(4):1594-1602. PubMed ID: 29394460
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Clinical validation of a 4D-CT based method for lung ventilation measurement in phantoms and patients.
    Nyeng TB; Kallehauge JF; Høyer M; Petersen JB; Poulsen PR; Muren LP
    Acta Oncol; 2011 Aug; 50(6):897-907. PubMed ID: 21767190
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Attenuation correction in 4D-PET using a single-phase attenuation map and rigidity-adaptive deformable registration.
    Kalantari F; Wang J
    Med Phys; 2017 Feb; 44(2):522-532. PubMed ID: 27987223
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Object-constrained meshless deformable algorithm for high speed 3D nonrigid registration between CT and CBCT.
    Chen T; Kim S; Goyal S; Jabbour S; Zhou J; Rajagopal G; Haffty B; Yue N
    Med Phys; 2010 Jan; 37(1):197-210. PubMed ID: 20175482
    [TBL] [Abstract][Full Text] [Related]  

  • 17. SU-E-I-87: Tumor Positioning for PET-CT Scanner by Jointly Registration and Segmentation.
    Li D; Yang J; Yin Y
    Med Phys; 2012 Jun; 39(6Part5):3645. PubMed ID: 28517633
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of an automated deformable image matching method for quantifying lung motion in respiration-correlated CT images.
    Pevsner A; Davis B; Joshi S; Hertanto A; Mechalakos J; Yorke E; Rosenzweig K; Nehmeh S; Erdi YE; Humm JL; Larson S; Ling CC; Mageras GS
    Med Phys; 2006 Feb; 33(2):369-76. PubMed ID: 16532942
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of mesh- and binary-based contour propagation methods in 4D thoracic radiotherapy treatments using patient 4D CT images.
    Ma Y; Liu X; Dai Z; He P; Yan Y; Shen G; Yuan P; Li Q
    Phys Med; 2017 Apr; 36():46-53. PubMed ID: 28410685
    [TBL] [Abstract][Full Text] [Related]  

  • 20. New algorithm to simulate organ movement and deformation for four-dimensional dose calculation based on a three-dimensional CT and fluoroscopy of the thorax.
    Miyabe Y; Narita Y; Mizowaki T; Matsuo Y; Takayama K; Takahashi K; Kaneko S; Kawada N; Maruhashi A; Hiraoka M
    Med Phys; 2009 Oct; 36(10):4328-39. PubMed ID: 19928063
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.