These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

204 related articles for article (PubMed ID: 17824919)

  • 1. Variable levels of carry over on platelet counts < or = 20 x 10(9)/l with the Bayer Advia 120.
    Mehmood S; Hinchliffe RF; Clark SJ; Bellamy GJ; Dennis MW; Welch JC; Vora AJ
    Int J Lab Hematol; 2007 Oct; 29(5):377-80. PubMed ID: 17824919
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Accuracy of platelet counting haematology analysers in severe thrombocytopenia and potential impact on platelet transfusion.
    Segal HC; Briggs C; Kunka S; Casbard A; Harrison P; Machin SJ; Murphy MF
    Br J Haematol; 2005 Feb; 128(4):520-5. PubMed ID: 15686462
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Problems with platelet counting in thrombocytopenia. A rapid manual method to measure low platelet counts.
    Sutor AH; Grohmann A; Kaufmehl K; Wündisch T
    Semin Thromb Hemost; 2001 Jun; 27(3):237-43. PubMed ID: 11446657
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of platelet counts in simultaneous venous and capillary blood samples using an automated platelet analyser.
    Tai DY; Chan KW; Chee YC; Mak KH
    Singapore Med J; 1995 Jun; 36(3):263-6. PubMed ID: 8553087
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Usefulness of immunoplatelet measurement using the flow cytometric method for accurate platelet counting in hematological patients with severe thrombocytopenia].
    Nishiyama M; Hayashi S; Futsukaichi Y; Suehisa E; Kurata Y
    Rinsho Byori; 2004 Feb; 52(2):103-8. PubMed ID: 15027312
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Platelet counting by the coulter LH 750, sysmex XE 2100, and advia 120: a comparative analysis using the RBC/platelet ratio reference method.
    Sandhaus LM; Osei ES; Agrawal NN; Dillman CA; Meyerson HJ
    Am J Clin Pathol; 2002 Aug; 118(2):235-41. PubMed ID: 12162684
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of platelet counts by CellDyn Sapphire (Abbot Diagnostics), LH750 (Beckman Coulter), ReaPanThrombo immunoplatelet method (ReaMetrix), and the international flow reference method, in thrombocytopenic blood samples.
    Sehgal K; Badrinath Y; Tembhare P; Subramanian PG; Talole S; Kumar A; Gadage V; Mahadik S; Ghogale S; Gujral S
    Cytometry B Clin Cytom; 2010 Jul; 78(4):279-85. PubMed ID: 20229505
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Automated platelet count in thrombocytopenic patients--a comparison of methods].
    Stibbe W; Weise M; Seidel D
    J Clin Chem Clin Biochem; 1985 Jul; 23(7):399-404. PubMed ID: 3930654
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Automated counting of platelets on the Bayer ADVIA 120 analyser.
    Stanworth SJ; Denton K; Monteath J; Patton WN
    Clin Lab Haematol; 1999 Apr; 21(2):113-7. PubMed ID: 10342070
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Possibilities and limitations of automated platelet counting procedures in the thrombocytopenic range.
    Kunz D
    Semin Thromb Hemost; 2001 Jun; 27(3):229-35. PubMed ID: 11446656
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of automated platelet counts and potential effect on transfusion decisions in cancer patients.
    Marionneaux S; Francisco N; Chan V; Hanenberg J; Rafael J; Chua C; Jia R; Yao J; Lynch J; Chan V; Maslak P
    Am J Clin Pathol; 2013 Nov; 140(5):747-54. PubMed ID: 24124156
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Implementation of the immunological method for improvement on accurate platelet counts].
    Osada E; Inose Y; Takeuchi K; Kawai Y; Watanabe K
    Rinsho Byori; 2002 Sep; 50(9):887-92. PubMed ID: 12386967
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [The clinical study of recombinant human thrombopoietin in the treatment of chemotherapy-induced severe thrombocytopenia].
    Bai CM; Zou XY; Zhao YQ; Han SM; Shan YD;
    Zhonghua Yi Xue Za Zhi; 2004 Mar; 84(5):397-400. PubMed ID: 15061993
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Is automated platelet counting still a problem in thrombocytopenic blood?
    Oliveira RA; Takadachi MM; Nonoyama K; Barretto OC
    Sao Paulo Med J; 2003 Jan; 121(1):19-23. PubMed ID: 12751339
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Evaluation of a new automatic hematological system: the Advia 70 (Bayer-Diagnostics)].
    Siguret V; Hanna N; Gouin I; Guetonny PD; Chevance C; Andreux JP
    Ann Biol Clin (Paris); 2002; 60(5):541-8. PubMed ID: 12368139
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Relationships between platelet counts, platelet volumes and reticulated platelets in patients with ITP: evidence for significant platelet count inaccuracies with conventional instrument methods.
    Diquattro M; Gagliano F; Calabrò GM; Tommasi M; Scott CS; Mancuso G; Palma B; Menozzi I
    Int J Lab Hematol; 2009 Apr; 31(2):199-206. PubMed ID: 18190589
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Erroneous automated optical platelet counts in 1-hour post-transfusion blood samples.
    Maurer-Spurej E; Pittendreigh C; Yakimec J; De Badyn MH; Chipperfield K
    Int J Lab Hematol; 2010 Feb; 32(1 Pt 1):e1-8. PubMed ID: 18752538
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Reliability of low platelet counts--comparison of microscopic counts with automated hematology analyzer XE-2100].
    Orito M; Shibayama M; Yoshida T; Takami A; Asakura H; Fujita S; Nakao S
    Rinsho Byori; 2005 Sep; 53(9):793-801. PubMed ID: 16235831
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Platelet count evaluation using three automated haematology analysers compared with the immunoplatelet reference method, and estimation of possible inadequate platelet transfusion.
    Hong KH; Kim MJ; Lee KW; Park KU; Kim HS; Song J
    Int J Lab Hematol; 2009 Jun; 31(3):298-306. PubMed ID: 18294237
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An evaluation of methods for determining reference intervals for light transmission platelet aggregation tests on samples with normal or reduced platelet counts.
    Hayward CP; Moffat KA; Pai M; Liu Y; Seecharan J; McKay H; Webert KE; Cook RJ; Heddle NM
    Thromb Haemost; 2008 Jul; 100(1):134-45. PubMed ID: 18612548
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.