141 related articles for article (PubMed ID: 17825807)
1. Cross-reactivities of macroprolactin and big-prolactin in three commercial immunoassays for prolactin: a chromatographic analysis.
Ellis MJ; Reed MR; Livesey JH
Clin Biochem; 2007 Nov; 40(16-17):1285-90. PubMed ID: 17825807
[TBL] [Abstract][Full Text] [Related]
2. Roche Elecsys Prolactin II assay: reactivity with macroprolactin compared with eight commercial assays for prolactin and determination of monomeric prolactin by precipitation with polyethylene glycol.
Fahie-Wilson M; Bieglmayer C; Kratzsch J; Nusbaumer C; Roth HJ; Zaninotto M; Plebani M; Hubbuch A; Schneider E
Clin Lab; 2007; 53(7-8):485-92. PubMed ID: 17821956
[TBL] [Abstract][Full Text] [Related]
3. Roche Elecsys Prolactin II assay: reactivity with macroprolactin compared with eight commercial assays for prolactin and determination of monomeric prolactin by precipitation with polyethylene glycol.
Fahie-Wilson M; Bieglmayer C; Kratzsch J; Nusbaumer C; Roth HJ; Zaninotto M; Plebani M; Hubbuch A; Schneider E
Clin Lab; 2007; 53(5-6):301-7. PubMed ID: 17605405
[TBL] [Abstract][Full Text] [Related]
4. Macroprolactin, big-prolactin and potential effects on the misdiagnosis of hyperprolactinemia using the Beckman Coulter Access Prolactin assay.
Ellis MJ; Livesey JH; Soule SG
Clin Biochem; 2006 Oct; 39(10):1028-34. PubMed ID: 16919253
[TBL] [Abstract][Full Text] [Related]
5. Free prolactin determinations in hyperprolactinemic men with suspicion of macroprolactinemia.
Sapin R; Gasser F; Grucker D
Clin Chim Acta; 2002 Feb; 316(1-2):33-41. PubMed ID: 11750272
[TBL] [Abstract][Full Text] [Related]
6. Prevalence of macroprolactin detected by Elecsys 2010.
Sánchez-Eixerés MR; Mauri M; Alfayate R; Graells ML; Miralles C; López A; Picó A
Horm Res; 2001; 56(3-4):87-92. PubMed ID: 11847468
[TBL] [Abstract][Full Text] [Related]
7. Gross variability in the detection of prolactin in sera containing big big prolactin (macroprolactin) by commercial immunoassays.
Smith TP; Suliman AM; Fahie-Wilson MN; McKenna TJ
J Clin Endocrinol Metab; 2002 Dec; 87(12):5410-5. PubMed ID: 12466327
[TBL] [Abstract][Full Text] [Related]
8. Serum total prolactin and monomeric prolactin reference intervals determined by precipitation with polyethylene glycol: evaluation and validation on common immunoassay platforms.
Beltran L; Fahie-Wilson MN; McKenna TJ; Kavanagh L; Smith TP
Clin Chem; 2008 Oct; 54(10):1673-81. PubMed ID: 18719199
[TBL] [Abstract][Full Text] [Related]
9. Reactivity of macroprolactin in common automated immunoassays.
Schneider W; Marcovitz S; Al-Shammari S; Yago S; Chevalier S
Clin Biochem; 2001 Sep; 34(6):469-73. PubMed ID: 11676976
[TBL] [Abstract][Full Text] [Related]
10. Identification of IgG-immunocomplex macroprolactin with an immunometric "sandwich" system: technical and clinical considerations.
Amadori P; Dilberis C; Marcolla A; Pinamonti M; Menapace P; Valentini A
J Endocrinol Invest; 2004 Dec; 27(11):1022-8. PubMed ID: 15754733
[TBL] [Abstract][Full Text] [Related]
11. Macroprolactin; high molecular mass forms of circulating prolactin.
Fahie-Wilson MN; John R; Ellis AR
Ann Clin Biochem; 2005 May; 42(Pt 3):175-92. PubMed ID: 15949152
[TBL] [Abstract][Full Text] [Related]
12. Macroprolactin(s): composition and reactivity in immunoassays and laboratory interpretation of results of an unusual patient serum.
Ellis AR; Fahie-Wilson M; Axcell M; Sands K; Hill RP
Ann Clin Biochem; 2006 Jan; 43(Pt 1):57-62. PubMed ID: 16390610
[TBL] [Abstract][Full Text] [Related]
13. Comparison of Four Automated Carcinoembryonic Antigen Immunoassays: ADVIA Centaur XP, ARCHITECT I2000sr, Elecsys E170, and Unicel Dxi800.
Park J; Lee S; Kim Y; Choi A; Lee H; Lim J; Kim Y; Han K; Oh EJ
Ann Lab Med; 2018 Jul; 38(4):355-361. PubMed ID: 29611386
[TBL] [Abstract][Full Text] [Related]
14. False-positive polyethylene glycol precipitation tests for macroprolactin due to increased serum globulins.
Ram S; Harris B; Fernando JJ; Gama R; Fahie-Wilson M
Ann Clin Biochem; 2008 May; 45(Pt 3):256-9. PubMed ID: 18482912
[TBL] [Abstract][Full Text] [Related]
15. Effect of albumin concentration on serum cortisol measured by the Bayer Advia Centaur assay.
Barnes SC; Swaminathan R
Ann Clin Biochem; 2007 Jan; 44(Pt 1):79-82. PubMed ID: 17270097
[TBL] [Abstract][Full Text] [Related]
16. Performance evaluation of the ADVIA Centaur anti-HBe and HBeAg assays.
van Helden J; Cornely C; Dati F; Levy HR; Bal T; Seeger M; Wright T; Baker L
J Clin Virol; 2008 Oct; 43(2):169-75. PubMed ID: 18635392
[TBL] [Abstract][Full Text] [Related]
17. Results from a multicenter evaluation of the 4th generation Elecsys Troponin T assay.
Hermsen D; Apple F; Garcia-Beltràn L; Jaffe A; Karon B; Lewandrowski E; Mühlbacher A; Müller R; Ordóñez J; Pagani F; Panteghini M; Plecko T; Jarausch J
Clin Lab; 2007; 53(1-2):1-9. PubMed ID: 17323819
[TBL] [Abstract][Full Text] [Related]
18. Macroprolactinaemia: a biological diagnostic strategy from the study of 222 patients.
Parlant-Pinet L; Harthé C; Roucher F; Morel Y; Borson-Chazot F; Raverot G; Raverot V
Eur J Endocrinol; 2015 Jun; 172(6):687-95. PubMed ID: 25755230
[TBL] [Abstract][Full Text] [Related]
19. Macroprolactinemia: predictability on clinical basis and detection by PEG precipitation with two different immunometric methods.
Amadori P; Dilberis C; Marcolla A; Pinamonti M; Menapace P; Dal Bosco F
J Endocrinol Invest; 2003 Feb; 26(2):148-56. PubMed ID: 12739743
[TBL] [Abstract][Full Text] [Related]
20. Determination of ultrafilterable prolactin: elimination of macroprolactin interference with a monomeric prolactin-selective sample pretreatment.
Quinn AM; Rubinas TC; Garbincius CJ; Holmes EW
Arch Pathol Lab Med; 2006 Dec; 130(12):1807-12. PubMed ID: 17149954
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]