120 related articles for article (PubMed ID: 17827590)
1. Atrial ECG as a guide to the placement of central venous catheter in patients undergoing Open Heart Surgery.
Tempe DK; Virmani S; Tomar AS; Datt V; Aggarwal N; Yadav S; Narang P; Minhas HS; Banerjee A
Ann Card Anaesth; 2003 Jan; 6(1):35-41. PubMed ID: 17827590
[TBL] [Abstract][Full Text] [Related]
2. [ECG-controlled placement of central venous catheters in patients with atrial fibrillation].
Engelhardt W; Sold M; Helzel MV
Anaesthesist; 1989 Sep; 38(9):476-9. PubMed ID: 2589630
[TBL] [Abstract][Full Text] [Related]
3. [Accurate placement of central venous catheters using right atrial electrocardiography].
Takebe S; Mashima Y; Yamamoto K; Yufu K; Hidaka H; Aono H
Masui; 1996 Mar; 45(3):326-30. PubMed ID: 8721132
[TBL] [Abstract][Full Text] [Related]
4. The accuracy of electrocardiogram-controlled central line placement.
Gebhard RE; Szmuk P; Pivalizza EG; Melnikov V; Vogt C; Warters RD
Anesth Analg; 2007 Jan; 104(1):65-70. PubMed ID: 17179244
[TBL] [Abstract][Full Text] [Related]
5. Central venous catheters--the inability of 'intra-atrial ECG' to prove adequate positioning.
Schummer W; Schummer C; Schelenz C; Brandes H; Stock U; Müller T; Leder U; Hüttemann E
Br J Anaesth; 2004 Aug; 93(2):193-8. PubMed ID: 15220179
[TBL] [Abstract][Full Text] [Related]
6. Application of intravenous electrocardiography for insertion of central veins dialysis catheters.
Beigi AA; Parvizian F; Masoudpour H
Saudi J Kidney Dis Transpl; 2009 Sep; 20(5):794-7. PubMed ID: 19736475
[TBL] [Abstract][Full Text] [Related]
7. Depth of a central venous catheter tip: length of insertion guideline for pediatric patients.
Yoon SZ; Shin TJ; Kim HS; Lee J; Kim CS; Kim SD; Park CD
Acta Anaesthesiol Scand; 2006 Mar; 50(3):355-7. PubMed ID: 16480470
[TBL] [Abstract][Full Text] [Related]
8. [Incorrect placement of a vena cava catheter and its prevention by intra-atrial ECG].
Schäfer M; Ciesielski K; Kuss B; Link J
Anaesthesist; 1988 Jan; 37(1):49-51. PubMed ID: 3354832
[TBL] [Abstract][Full Text] [Related]
9. Transesophageal echocardiography for verification of the position of the electrocardiographically-placed central venous catheter.
Ender J; Erdoes G; Krohmer E; Olthoff D; Mukherjee C
J Cardiothorac Vasc Anesth; 2009 Aug; 23(4):457-61. PubMed ID: 19217801
[TBL] [Abstract][Full Text] [Related]
10. [Accurate placement of central venous catheter--ECG-guided method vs patient height method].
Nakatani K; Nishikawa K; Funao T; Ikeda Y; Nakasuji K; Iida Y; Nishi S; Asada A
Masui; 2002 Jan; 51(1):34-8. PubMed ID: 11840660
[TBL] [Abstract][Full Text] [Related]
11. [Positioning of central venous catheters using ECG].
Kjelstrup T; Ludwig M; Hüsch M
Tidsskr Nor Laegeforen; 1991 Feb; 111(5):599-601. PubMed ID: 2008677
[TBL] [Abstract][Full Text] [Related]
12. Correct depth of insertion of right internal jugular central venous catheters based on external landmarks: avoiding the right atrium.
Ezri T; Weisenberg M; Sessler DI; Berkenstadt H; Elias S; Szmuk P; Serour F; Evron S
J Cardiothorac Vasc Anesth; 2007 Aug; 21(4):497-501. PubMed ID: 17678774
[TBL] [Abstract][Full Text] [Related]
13. [Extravasal position of central venous catheters despite unsuspicious ECG-guidance].
Schummer W; Schummer C; Paxian M; Stock U; Richter K; Bauer M
Anasthesiol Intensivmed Notfallmed Schmerzther; 2005 Feb; 40(2):91-6. PubMed ID: 15714399
[TBL] [Abstract][Full Text] [Related]
14. [Clinical use of a new cava catheter with an ECG lead over a steel mandrin].
Hausser J
Anaesthesist; 1990 Apr; 39(4):240-2. PubMed ID: 2339777
[TBL] [Abstract][Full Text] [Related]
15. Efficacy of the CathRite system to guide bedside placement of peripherally inserted central venous catheters in critically ill patients: a pilot study.
Hockley SJ; Hamilton V; Young RJ; Chapman MJ; Taylor J; Creed S; Chorley DP; Williams DB; de M Tippett M
Crit Care Resusc; 2007 Sep; 9(3):251-5. PubMed ID: 17767451
[TBL] [Abstract][Full Text] [Related]
16. [Intra-atrial ECG via a central venous catheter].
Uhrbrand B; Pedersen FM; Stolberg EF; Ferguson AH
Ugeskr Laeger; 1990 Jan; 152(5):320-2. PubMed ID: 2301082
[TBL] [Abstract][Full Text] [Related]
17. Intravenous electrocardiography helps inexperienced operators to place totally implantable venous access device more accurately.
Wang YC; Huang CH; Lin FS; Lin WY; Fan SZ; Lin CP; Sun WZ
J Surg Oncol; 2012 Jun; 105(8):848-51. PubMed ID: 22161950
[TBL] [Abstract][Full Text] [Related]
18. Peripherally inserted central catheter placement in patients with unsuspected central venous obstruction.
Park KB; Choo SW; Do YS; Shin SW; Cho SK; Choe YH; Yoo SY; Kim JH; Choo IW
J Vasc Interv Radiol; 2008 Apr; 19(4):552-6. PubMed ID: 18375300
[TBL] [Abstract][Full Text] [Related]
19. Placement of hemodialysis catheters through stenotic or occluded central thoracic veins.
Haller C; Déglise S; Saucy F; Mathieu C; Haesler E; Doenz F; Corpataux JM; Qanadli SD
Cardiovasc Intervent Radiol; 2009 Jul; 32(4):695-702. PubMed ID: 19449059
[TBL] [Abstract][Full Text] [Related]
20. [Central venous catheter location by endocavitary ECG: an alternative to chest radiography].
Calabuig R; Sueiras A; Galera MJ; Ortiz C; Pi F; Sierra E
Med Clin (Barc); 1997 Sep; 109(9):324-7. PubMed ID: 9379762
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]