93 related articles for article (PubMed ID: 17888256)
1. [Stress analysis of the staggered and straight placement of implants in the mandibular posterior region under the localized load].
Li Y; Zhou YM; Zhou ZP; Wang X
Zhonghua Kou Qiang Yi Xue Za Zhi; 2007 Jun; 42(6):365-7. PubMed ID: 17888256
[TBL] [Abstract][Full Text] [Related]
2. Finite element stress analysis of the influence of staggered versus straight placement of dental implants.
Akça K; Iplikçioğlu H
Int J Oral Maxillofac Implants; 2001; 16(5):722-30. PubMed ID: 11669255
[TBL] [Abstract][Full Text] [Related]
3. Finite element analysis of effect of prosthesis height, angle of force application, and implant offset on supporting bone.
Sütpideler M; Eckert SE; Zobitz M; An KN
Int J Oral Maxillofac Implants; 2004; 19(6):819-25. PubMed ID: 15623056
[TBL] [Abstract][Full Text] [Related]
4. Finite element stress analysis of dental prostheses supported by straight and angled implants.
Cruz M; Wassall T; Toledo EM; da Silva Barra LP; Cruz S
Int J Oral Maxillofac Implants; 2009; 24(3):391-403. PubMed ID: 19587860
[TBL] [Abstract][Full Text] [Related]
5. Implant-bone interface stress distribution in immediately loaded implants of different diameters: a three-dimensional finite element analysis.
Ding X; Zhu XH; Liao SH; Zhang XH; Chen H
J Prosthodont; 2009 Jul; 18(5):393-402. PubMed ID: 19374710
[TBL] [Abstract][Full Text] [Related]
6. Biomechanical comparison of straight and staggered implant placement configurations.
Itoh H; Caputo AA; Kuroe T; Nakahara H
Int J Periodontics Restorative Dent; 2004 Feb; 24(1):47-55. PubMed ID: 14984145
[TBL] [Abstract][Full Text] [Related]
7. An evaluation of torque (moment) on implant/prosthesis with staggered buccal and lingual offset.
Weinberg LA; Kruger B
Int J Periodontics Restorative Dent; 1996 Jun; 16(3):252-65. PubMed ID: 9084311
[TBL] [Abstract][Full Text] [Related]
8. Effects of different inter-implant distances on the stress distribution around endosseous implants in posterior mandible: a 3D finite element analysis.
Simşek B; Erkmen E; Yilmaz D; Eser A
Med Eng Phys; 2006 Apr; 28(3):199-213. PubMed ID: 15979921
[TBL] [Abstract][Full Text] [Related]
9. The staggered installation of dental implants and its effect on bone stresses.
Abu-Hammad O; Khraisat A; Dar-Odeh N; Jagger DC; Hammerle CH
Clin Implant Dent Relat Res; 2007 Sep; 9(3):121-7. PubMed ID: 17716255
[TBL] [Abstract][Full Text] [Related]
10. Effects of different fixture geometries on the stress distribution in mandibular peri-implant structures: a 3-dimensional finite element analysis.
Degerliyurt K; Simsek B; Erkmen E; Eser A
Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2010 Aug; 110(2):e1-11. PubMed ID: 20598590
[TBL] [Abstract][Full Text] [Related]
11. The influence of implant diameter and length on stress distribution of osseointegrated implants related to crestal bone geometry: a three-dimensional finite element analysis.
Baggi L; Cappelloni I; Di Girolamo M; Maceri F; Vairo G
J Prosthet Dent; 2008 Dec; 100(6):422-31. PubMed ID: 19033026
[TBL] [Abstract][Full Text] [Related]
12. Biomechanical rationale for intentionally inclined implants in the posterior mandible using 3D finite element analysis.
Satoh T; Maeda Y; Komiyama Y
Int J Oral Maxillofac Implants; 2005; 20(4):533-9. PubMed ID: 16161737
[TBL] [Abstract][Full Text] [Related]
13. Biomechanical response of implant systems placed in the maxillary posterior region under various conditions of angulation, bone density, and loading.
Lin CL; Wang JC; Ramp LC; Liu PR
Int J Oral Maxillofac Implants; 2008; 23(1):57-64. PubMed ID: 18416413
[TBL] [Abstract][Full Text] [Related]
14. Two-dimensional finite element analysis of the influence of bridge design on stress distribution in bone tissues surrounding fixtures of osseointegrated implants in the lower molar region.
Arataki T; Adachi Y; Kishi M
Bull Tokyo Dent Coll; 1998 Aug; 39(3):199-209. PubMed ID: 9927906
[TBL] [Abstract][Full Text] [Related]
15. Three-dimensional finite element analysis of the effect of different bone quality on stress distribution in an implant-supported crown.
Sevimay M; Turhan F; Kiliçarslan MA; Eskitascioglu G
J Prosthet Dent; 2005 Mar; 93(3):227-34. PubMed ID: 15775923
[TBL] [Abstract][Full Text] [Related]
16. Tilting of posterior mandibular and maxillary implants for improved prosthesis support.
Krekmanov L; Kahn M; Rangert B; Lindström H
Int J Oral Maxillofac Implants; 2000; 15(3):405-14. PubMed ID: 10874806
[TBL] [Abstract][Full Text] [Related]
17. Effects of splinted prosthesis supported a wide implant or two implants: a three-dimensional finite element analysis.
Huang HL; Huang JS; Ko CC; Hsu JT; Chang CH; Chen MY
Clin Oral Implants Res; 2005 Aug; 16(4):466-72. PubMed ID: 16117772
[TBL] [Abstract][Full Text] [Related]
18. A three-dimensional finite element study on two versus four implants in an edentulous mandible.
Meijer HJ; Starmans FJ; Steen WH; Bosman F
Int J Prosthodont; 1994; 7(3):271-9. PubMed ID: 7916894
[TBL] [Abstract][Full Text] [Related]
19. Three-dimensional finite element analysis of load transmission using different implant inclinations and cantilever lengths.
Bevilacqua M; Tealdo T; Pera F; Menini M; Mossolov A; Drago C; Pera P
Int J Prosthodont; 2008; 21(6):539-42. PubMed ID: 19149073
[TBL] [Abstract][Full Text] [Related]
20. Finite element stress analysis of cuneiform and cylindrical threaded implant geometries.
Cruz M; Lourenço AF; Toledo EM; da Silva Barra LP; de Castro Lemonge AC; Wassall T
Technol Health Care; 2006; 14(4-5):421-38. PubMed ID: 17065763
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]