216 related articles for article (PubMed ID: 17889550)
1. Is the Allen test reliable enough?
Kohonen M; Teerenhovi O; Terho T; Laurikka J; Tarkka M
Eur J Cardiothorac Surg; 2007 Dec; 32(6):902-5. PubMed ID: 17889550
[TBL] [Abstract][Full Text] [Related]
2. Is radial artery Doppler scanning mandatory for use as coronary bypass conduit?
Yadava OP; Dinda AK; Mohanty BK; Mishra R; Ahlawat V; Kundu A
Asian Cardiovasc Thorac Ann; 2015 Sep; 23(7):822-7. PubMed ID: 26071450
[TBL] [Abstract][Full Text] [Related]
3. Non-harvestable radial artery. A bilateral problem?
Kohonen M; Teerenhovi O; Terho T; Laurikka J; Tarkka M
Interact Cardiovasc Thorac Surg; 2008 Oct; 7(5):797-800. PubMed ID: 18469006
[TBL] [Abstract][Full Text] [Related]
4. Preoperative assessment of hand circulation by means of Doppler ultrasonography and the modified Allen test.
Ruengsakulrach P; Brooks M; Hare DL; Gordon I; Buxton BF
J Thorac Cardiovasc Surg; 2001 Mar; 121(3):526-31. PubMed ID: 11241088
[TBL] [Abstract][Full Text] [Related]
5. Duplex ultrasonography predicts safety of radial artery harvest in the presence of an abnormal Allen test.
Abu-Omar Y; Mussa S; Anastasiadis K; Steel S; Hands L; Taggart DP
Ann Thorac Surg; 2004 Jan; 77(1):116-9. PubMed ID: 14726046
[TBL] [Abstract][Full Text] [Related]
6. [Color Doppler US evaluation of hand circulation before radial artery harvest for coronary artery bypass grafting].
Conkbayir I; Yanik B; Ozkanli BS; Düzgün C; Hekimoğlu B
Tani Girisim Radyol; 2003 Sep; 9(3):377-81. PubMed ID: 14661608
[TBL] [Abstract][Full Text] [Related]
7. Preoperative assessment of the radial artery for coronary artery bypass grafting: is the clinical Allen test adequate?
Agrifoglio M; Dainese L; Pasotti S; Galanti A; Cannata A; Roberto M; Parolari A; Biglioli P
Ann Thorac Surg; 2005 Feb; 79(2):570-2. PubMed ID: 15680837
[TBL] [Abstract][Full Text] [Related]
8. The role of preoperative radial artery ultrasound and digital plethysmography prior to coronary artery bypass grafting.
Rodriguez E; Ormont ML; Lambert EH; Needleman L; Halpern EJ; Diehl JT; Edie RN; Mannion JD
Eur J Cardiothorac Surg; 2001 Feb; 19(2):135-9. PubMed ID: 11167101
[TBL] [Abstract][Full Text] [Related]
9. Noninvasive evaluation of hand circulation before radial artery harvest for coronary artery bypass grafting.
Starnes SL; Wolk SW; Lampman RM; Shanley CJ; Prager RL; Kong BK; Fowler JJ; Page JM; Babcock SL; Lange LA; Erlandson EE; Whitehouse WM
J Thorac Cardiovasc Surg; 1999 Feb; 117(2):261-6. PubMed ID: 9918966
[TBL] [Abstract][Full Text] [Related]
10. Extrafascially harvested radial artery in CABG: technique of harvest, complications, and mid-term angiographic patency.
Sajja LR; Mannam G; Sompalli S
J Card Surg; 2005; 20(5):440-8. PubMed ID: 16153275
[TBL] [Abstract][Full Text] [Related]
11. Intraoperative pressure measurement in radial artery harvest. A tool with additional value?
Kohonen M; Teerenhovi O; Taskinen P; Nissinen J; Loponen P; Luther M; Tarkka M
Scand J Surg; 2010; 99(4):221-5. PubMed ID: 21159592
[TBL] [Abstract][Full Text] [Related]
12. Radial artery harvesting for coronary artery bypass grafting: a stepwise-made decision.
Vuković PM; Radak SS; Perić MS; Nezić DG; Knezević AM
Ann Thorac Surg; 2008 Sep; 86(3):828-31. PubMed ID: 18721569
[TBL] [Abstract][Full Text] [Related]
13. Neurological status and tissue perfusion changes after radial artery harvesting for myocardial revascularization: importance of the Allen test.
Ikizler M; Entok E; Ozdemir C; Dernek S; Sevin B; Kural T
Thorac Cardiovasc Surg; 2007 Mar; 55(2):99-103. PubMed ID: 17377862
[TBL] [Abstract][Full Text] [Related]
14. Assessment of ulnar collateral circulation by the Allen test in patients undergoing radial artery harvest.
Sajja LR
Eur J Cardiothorac Surg; 2008 Apr; 33(4):755, author reply 756. PubMed ID: 18282713
[No Abstract] [Full Text] [Related]
15. Hand circulation after radial artery harvest for coronary artery bypass grafting.
Manabe S; Tabuchi N; Tanaka H; Arai H; Sunamori M
J Med Dent Sci; 2005 Jun; 52(2):101-7. PubMed ID: 16187615
[TBL] [Abstract][Full Text] [Related]
16. Measurement of ulnar flow is helpful in predicting ischemia after radial artery harvest.
Manabe S; Tabuchi N; Toyama M; Kuriu K; Mizuno T; Sunamori M
Thorac Cardiovasc Surg; 2002 Dec; 50(6):325-8. PubMed ID: 12457306
[TBL] [Abstract][Full Text] [Related]
17. Radial artery compression in incomplete palmar arch for radial artery harvesting.
Mohite PN; Thingnam SK; Saxena AK
Asian Cardiovasc Thorac Ann; 2014 May; 22(4):416-20. PubMed ID: 24771729
[TBL] [Abstract][Full Text] [Related]
18. Correlation of modified allen test with Doppler ultrasonography.
Cagli K; Uzun A; Emir M; Bakuy V; Ulas M; Sener E
Asian Cardiovasc Thorac Ann; 2006 Apr; 14(2):105-8. PubMed ID: 16551815
[TBL] [Abstract][Full Text] [Related]
19. [Reliability and validity of the modified Allen test: a systematic review and metanalysis].
Romeu-Bordas Ó; Ballesteros-Peña S
Emergencias; 2017 Abr; 29(2):126-135. PubMed ID: 28825257
[TBL] [Abstract][Full Text] [Related]
20. Laser speckle contrast analysis for quantifying the Allen test: a feasibility study.
Sandker SC; Hondebrink E; Grandjean JG; Steenbergen W
Lasers Surg Med; 2014 Mar; 46(3):186-92. PubMed ID: 24302298
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]