These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

400 related articles for article (PubMed ID: 17889601)

  • 21. Combination of EEG and ECG for improved automatic neonatal seizure detection.
    Greene BR; Boylan GB; Reilly RB; de Chazal P; Connolly S
    Clin Neurophysiol; 2007 Jun; 118(6):1348-59. PubMed ID: 17398146
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Seizure detection: evaluation of the Reveal algorithm.
    Wilson SB; Scheuer ML; Emerson RG; Gabor AJ
    Clin Neurophysiol; 2004 Oct; 115(10):2280-91. PubMed ID: 15351370
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Automated real-time epileptic seizure detection in scalp EEG recordings using an algorithm based on wavelet packet transform.
    Zandi AS; Javidan M; Dumont GA; Tafreshi R
    IEEE Trans Biomed Eng; 2010 Jul; 57(7):1639-51. PubMed ID: 20659825
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A neural network method for automatic and incremental learning applied to patient-dependent seizure detection.
    Wilson SB
    Clin Neurophysiol; 2005 Aug; 116(8):1785-95. PubMed ID: 16005680
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Do false predictions of seizures depend on the state of vigilance? A report from two seizure-prediction methods and proposed remedies.
    Schelter B; Winterhalder M; Maiwald T; Brandt A; Schad A; Timmer J; Schulze-Bonhage A
    Epilepsia; 2006 Dec; 47(12):2058-70. PubMed ID: 17201704
    [TBL] [Abstract][Full Text] [Related]  

  • 26. An evaluation of automated neonatal seizure detection methods.
    Faul S; Boylan G; Connolly S; Marnane L; Lightbody G
    Clin Neurophysiol; 2005 Jul; 116(7):1533-41. PubMed ID: 15897008
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Canonical decomposition of ictal scalp EEG reliably detects the seizure onset zone.
    De Vos M; Vergult A; De Lathauwer L; De Clercq W; Van Huffel S; Dupont P; Palmini A; Van Paesschen W
    Neuroimage; 2007 Sep; 37(3):844-54. PubMed ID: 17618128
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Effect of detection parameters on automated electroencephalography spike detection sensitivity and false-positive rate.
    Ver Hoef L; Elgavish R; Knowlton RC
    J Clin Neurophysiol; 2010 Feb; 27(1):12-6. PubMed ID: 20087204
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A patient-specific algorithm for the detection of seizure onset in long-term EEG monitoring: possible use as a warning device.
    Qu H; Gotman J
    IEEE Trans Biomed Eng; 1997 Feb; 44(2):115-22. PubMed ID: 9214791
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Seizure detection algorithm for neonates based on wave-sequence analysis.
    Navakatikyan MA; Colditz PB; Burke CJ; Inder TE; Richmond J; Williams CE
    Clin Neurophysiol; 2006 Jun; 117(6):1190-203. PubMed ID: 16621690
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Ictal localization by source analysis of infraslow activity in DC-coupled scalp EEG recordings.
    Miller JW; Kim W; Holmes MD; Vanhatalo S
    Neuroimage; 2007 Apr; 35(2):583-97. PubMed ID: 17275335
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Long-term prospective on-line real-time seizure prediction.
    Iasemidis LD; Shiau DS; Pardalos PM; Chaovalitwongse W; Narayanan K; Prasad A; Tsakalis K; Carney PR; Sackellares JC
    Clin Neurophysiol; 2005 Mar; 116(3):532-44. PubMed ID: 15721067
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Detection of epileptic seizures in scalp electroencephalogram: an automated real-time wavelet-based approach.
    Zandi AS; Dumont GA; Javidan M; Tafreshi R
    J Clin Neurophysiol; 2012 Feb; 29(1):1-16. PubMed ID: 22353980
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Automated artifact removal as preprocessing refines neonatal seizure detection.
    De Vos M; Deburchgraeve W; Cherian PJ; Matic V; Swarte RM; Govaert P; Visser GH; Van Huffel S
    Clin Neurophysiol; 2011 Dec; 122(12):2345-54. PubMed ID: 21705269
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Subdural EEG classification into seizure and nonseizure files using neural networks in the gamma frequency band.
    Ayala M; Cabrerizo M; Jayakar P; Adjouadi M
    J Clin Neurophysiol; 2011 Feb; 28(1):20-9. PubMed ID: 21221013
    [TBL] [Abstract][Full Text] [Related]  

  • 36. An automatic patient-specific seizure onset detection method in intracranial EEG based on incremental nonlinear dimensionality reduction.
    Zhang Y; Xu G; Wang J; Liang L
    Comput Biol Med; 2010; 40(11-12):889-99. PubMed ID: 20951372
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [Long-term EEG monitoring in epilepsy diagnosis].
    Zschocke S; Alexopoulos T
    Fortschr Neurol Psychiatr; 1984 Dec; 52(12):438-50. PubMed ID: 6440840
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Automated neonatal seizure detection: a multistage classification system through feature selection based on relevance and redundancy analysis.
    Aarabi A; Wallois F; Grebe R
    Clin Neurophysiol; 2006 Feb; 117(2):328-40. PubMed ID: 16376606
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Predicting epileptic seizures from scalp EEG based on attractor state analysis.
    Chu H; Chung CK; Jeong W; Cho KH
    Comput Methods Programs Biomed; 2017 May; 143():75-87. PubMed ID: 28391821
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Accuracy of seizure detection using abbreviated EEG during polysomnography.
    Foldvary-Schaefer N; De Ocampo J; Mascha E; Burgess R; Dinner D; Morris H
    J Clin Neurophysiol; 2006 Feb; 23(1):68-71. PubMed ID: 16514353
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 20.