These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
1228 related articles for article (PubMed ID: 17893451)
1. Accuracy of cerebral monitoring in detecting cerebral ischemia during carotid endarterectomy: a comparison of transcranial Doppler sonography, near-infrared spectroscopy, stump pressure, and somatosensory evoked potentials. Moritz S; Kasprzak P; Arlt M; Taeger K; Metz C Anesthesiology; 2007 Oct; 107(4):563-9. PubMed ID: 17893451 [TBL] [Abstract][Full Text] [Related]
2. The value of near-infrared spectroscopy measured cerebral oximetry during carotid endarterectomy in perioperative stroke prevention. A review. Pennekamp CW; Bots ML; Kappelle LJ; Moll FL; de Borst GJ Eur J Vasc Endovasc Surg; 2009 Nov; 38(5):539-45. PubMed ID: 19665397 [TBL] [Abstract][Full Text] [Related]
3. The accuracy of jugular bulb venous monitoring in detecting cerebral ischemia in awake patients undergoing carotid endarterectomy. Moritz S; Kasprzak P; Woertgen C; Taeger K; Metz C J Neurosurg Anesthesiol; 2008 Jan; 20(1):8-14. PubMed ID: 18157019 [TBL] [Abstract][Full Text] [Related]
4. Near-infrared spectroscopy to indicate selective shunt use during carotid endarterectomy. Pennekamp CW; Immink RV; den Ruijter HM; Kappelle LJ; Bots ML; Buhre WF; Moll FL; de Borst GJ Eur J Vasc Endovasc Surg; 2013 Oct; 46(4):397-403. PubMed ID: 23973277 [TBL] [Abstract][Full Text] [Related]
5. [Somatosensory evoked potentials and biochemical markers of neuronal deficits in patients undergoing carotid endarterectomy under regional anesthesia]. Schneemilch CE; Ludwig S; Ulrich A; Halloul Z; Hachenberg T Zentralbl Chir; 2007 Jun; 132(3):176-82. PubMed ID: 17610185 [TBL] [Abstract][Full Text] [Related]
6. Early detection of cerebral ischemia during carotid endarterectomy using transcranial Doppler sonography and somatosensory evoked potentials. Thiel A; Russ W; Nestle HW; Hempelmann G Thorac Cardiovasc Surg; 1989 Apr; 37(2):115-8. PubMed ID: 2727982 [TBL] [Abstract][Full Text] [Related]
7. [Clinical application of portable near infrared oximetry (HEO-200) to neurosurgical monitoring]. Kuroda S; Houkin K; Kobayashi T; Yasuda H; Ushikoshi S; Saito H; Abe H No Shinkei Geka; 2000 Jul; 28(7):607-13. PubMed ID: 10920822 [TBL] [Abstract][Full Text] [Related]
8. [Benefits and effectiveness of recording somatosensory evoked potentials in surgery on the carotid artery]. Uberrück T; Meyer L; Schmidt H; Gastinger I Zentralbl Chir; 2004 Jun; 129(3):172-7. PubMed ID: 15237320 [TBL] [Abstract][Full Text] [Related]
10. Good correlation between cerebral oxygenation measured using near infrared spectroscopy and stump pressure during carotid clamping. Yamamoto K; Miyata T; Nagawa H Int Angiol; 2007 Sep; 26(3):262-5. PubMed ID: 17622209 [TBL] [Abstract][Full Text] [Related]
11. Near-infrared spectroscopy can predict the onset of cerebral hyperperfusion syndrome after carotid endarterectomy. Pennekamp CW; Immink RV; den Ruijter HM; Kappelle LJ; Ferrier CM; Bots ML; Buhre WF; Moll FL; de Borst GJ Cerebrovasc Dis; 2012; 34(4):314-21. PubMed ID: 23146912 [TBL] [Abstract][Full Text] [Related]
12. Regional cerebral saturation versus transcranial Doppler during carotid endarterectomy under regional anaesthesia. Pugliese F; Ruberto F; Tosi A; Martelli S; Bruno K; Summonti D; D'Alio A; Diana B; Anile M; Panico A; Speziale F; Pietropaoli P Eur J Anaesthesiol; 2009 Aug; 26(8):643-7. PubMed ID: 19494780 [TBL] [Abstract][Full Text] [Related]
13. Hemodynamic cerebral ischemia during carotid endarterectomy evaluated by intraoperative monitoring and post-operative diffusion-weighted imaging. Uno M; Suzue A; Nishi K; Nagahiro S Neurol Res; 2007 Jan; 29(1):70-7. PubMed ID: 17427279 [TBL] [Abstract][Full Text] [Related]
14. Cerebral monitors versus regional anesthesia to detect cerebral ischemia in patients undergoing carotid endarterectomy: a meta-analysis. Guay J; Kopp S Can J Anaesth; 2013 Mar; 60(3):266-79. PubMed ID: 23385550 [TBL] [Abstract][Full Text] [Related]
15. Prevention of ischemic neurologic injury with intraoperative monitoring of selected cardiovascular and cerebrovascular procedures: roles of electroencephalography, somatosensory evoked potentials, transcranial Doppler, and near-infrared spectroscopy. Sloan MA Neurol Clin; 2006 Nov; 24(4):631-45. PubMed ID: 16935192 [TBL] [Abstract][Full Text] [Related]
16. [Malfunctioning of cerebral function monitors in three cases of carotid endarterectomy]. Kadoi Y; Kawahara F; Fujita N Masui; 2000 Jan; 49(1):40-4. PubMed ID: 10689842 [TBL] [Abstract][Full Text] [Related]
17. Prospective evaluation of electroencephalography, carotid artery stump pressure, and neurologic changes during 314 consecutive carotid endarterectomies performed in awake patients. Hans SS; Jareunpoon O J Vasc Surg; 2007 Mar; 45(3):511-5. PubMed ID: 17275248 [TBL] [Abstract][Full Text] [Related]
18. Neuromonitoring in carotid surgery: are the results obtained in awake patients transferable to patients under sevoflurane/fentanyl anesthesia? Moritz S; Schmidt C; Bucher M; Wiesenack C; Zimmermann M; Schebesch KM; Kasprzak P; Metz C J Neurosurg Anesthesiol; 2010 Oct; 22(4):288-95. PubMed ID: 20479662 [TBL] [Abstract][Full Text] [Related]
19. A clinical evaluation of near-infrared cerebral oximetry in the awake patient to monitor cerebral perfusion during carotid endarterectomy. Rigamonti A; Scandroglio M; Minicucci F; Magrin S; Carozzo A; Casati A J Clin Anesth; 2005 Sep; 17(6):426-30. PubMed ID: 16171662 [TBL] [Abstract][Full Text] [Related]
20. [Measurement of local oxygen parameters for detection of cerebral ischemia. The significance of cerebral near-infrared spectroscopy and transconjunctival oxygen partial pressure in carotid surgery]. Michel A; Weigand MA; Eckstein HH; Martin E; Bardenheuer HJ Anaesthesist; 2000 May; 49(5):392-401. PubMed ID: 10883353 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]