BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

382 related articles for article (PubMed ID: 17894537)

  • 1. Comparative analysis of methods to measure aerosols generated by a vibrating mesh nebulizer.
    Waldrep JC; Berlinski A; Dhand R
    J Aerosol Med; 2007; 20(3):310-9. PubMed ID: 17894537
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Aerodynamic particle size analysis of aerosols from pressurized metered-dose inhalers: comparison of Andersen 8-stage cascade impactor, next generation pharmaceutical impactor, and model 3321 Aerodynamic Particle Sizer aerosol spectrometer.
    Mitchell JP; Nagel MW; Wiersema KJ; Doyle CC
    AAPS PharmSciTech; 2003 Oct; 4(4):E54. PubMed ID: 15198549
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effects of flow pattern, device and formulation on particle size distribution of nebulized aerosol.
    Hu J; Zhang R; Beng H; Deng L; Ke Q; Tan W
    Int J Pharm; 2019 Apr; 560():35-46. PubMed ID: 30664994
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Optimization of a procedure used to measure aerosol characteristics of nebulized solutions using a cooled next generation impactor.
    Berlinski A; Hayden JB
    J Aerosol Med Pulm Drug Deliv; 2010 Dec; 23(6):397-404. PubMed ID: 20958142
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A system for the production and delivery of monodisperse salbutamol aerosols to the lungs.
    Biddiscombe MF; Usmani OS; Barnes PJ
    Int J Pharm; 2003 Mar; 254(2):243-53. PubMed ID: 12623200
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Aerosol delivery of recombinant human DNase I: in vitro comparison of a vibrating-mesh nebulizer with a jet nebulizer.
    Johnson JC; Waldrep JC; Guo J; Dhand R
    Respir Care; 2008 Dec; 53(12):1703-8. PubMed ID: 19025706
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of nebulized particle size distribution with Malvern laser diffraction analyzer versus Andersen cascade impactor and low-flow Marple personal cascade impactor.
    Kwong WT; Ho SL; Coates AL
    J Aerosol Med; 2000; 13(4):303-14. PubMed ID: 11262437
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Application of a droplet evaporation model to aerodynamic size measurement of drug aerosols generated by a vibrating mesh nebulizer.
    Rao N; Kadrichu N; Ament B
    J Aerosol Med Pulm Drug Deliv; 2010 Oct; 23(5):295-302. PubMed ID: 20455771
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Discriminating Ability of Abbreviated Impactor Measurement Approach (AIM) to Detect Changes in Mass Median Aerodynamic Diameter (MMAD) of an Albuterol/Salbutamol pMDI Aerosol.
    David Christopher J; Patel RB; Mitchell JP; Tougas TP; Goodey AP; Quiroz J; Andersson PU; Lyapustina S
    AAPS PharmSciTech; 2017 Nov; 18(8):3296-3306. PubMed ID: 28589305
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Aerodynamic characteristics of nebulized terbutaline sulphate using the Andersen Cascade Impactor compared to the Next Generation Impactor.
    Abdelrahim ME
    Pharm Dev Technol; 2011 Apr; 16(2):137-45. PubMed ID: 20100034
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Physicochemical aspects and efficiency of albuterol nebulization: comparison of three aerosol types in an in vitro pediatric model.
    Sidler-Moix AL; Di Paolo ER; Dolci U; Berger-Gryllaki M; Cotting J; Pannatier A
    Respir Care; 2015 Jan; 60(1):38-46. PubMed ID: 25516995
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of nebulizer performance under various humidity conditions.
    Zhou Y; Ahuja A; Irvin CM; Kracko D; McDonald JD; Cheng YS
    J Aerosol Med; 2005; 18(3):283-93. PubMed ID: 16181003
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Omron NE U22: Comparison between vibrating mesh and jet nebulizer.
    Skaria S; Smaldone GC
    J Aerosol Med Pulm Drug Deliv; 2010 Jun; 23(3):173-80. PubMed ID: 20500093
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Influence of impactor operating flow rate on particle size distribution of four jet nebulizers.
    Zhou Y; Brasel TL; Kracko D; Cheng YS; Ahuja A; Norenberg JP; Kelly HW
    Pharm Dev Technol; 2007; 12(4):353-9. PubMed ID: 17763140
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Formulations generated from ethanol-based proliposomes for delivery via medical nebulizers.
    Elhissi AM; Karnam KK; Danesh-Azari MR; Gill HS; Taylor KM
    J Pharm Pharmacol; 2006 Jul; 58(7):887-94. PubMed ID: 16805947
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Albuterol delivery in an in vitro pediatric ventilator lung model: comparison of jet, ultrasonic, and mesh nebulizers.
    Sidler-Moix AL; Dolci U; Berger-Gryllaki M; Pannatier A; Cotting J; Di Paolo ER
    Pediatr Crit Care Med; 2013 Feb; 14(2):e98-102. PubMed ID: 23287904
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Determination of nebulizer droplet size distribution: a method based on impactor refrigeration.
    Berg E; Svensson JO; Asking L
    J Aerosol Med; 2007; 20(2):97-104. PubMed ID: 17536948
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Medical nebulizer performance: effects of cascade impactor temperature.
    Zhou Y; Ahuja A; Irvin CM; Kracko DA; McDonald JD; Cheng YS
    Respir Care; 2005 Aug; 50(8):1077-82. PubMed ID: 16225713
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of Oxygen Flow on Aerosol Delivery From a Nebulizer With a Holding Chamber.
    Sarhan RM; Elberry AA; Abdelwahab NS; Rabea H; Salem MN; Abdelrahim ME
    Respir Care; 2019 Dec; 64(12):1508-1515. PubMed ID: 31387895
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Use of the next generation pharmaceutical impactor for particle size distribution measurements of live viral aerosol vaccines.
    Leung K; Louca E; Gray M; Tipples G; Coates AL
    J Aerosol Med; 2005; 18(4):414-26. PubMed ID: 16379617
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 20.