These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

391 related articles for article (PubMed ID: 17896842)

  • 1. Tympanic thermometry is unsuitable as a screening tool for hypothermia after open water swimming.
    Rogers IR; Brannigan D; Montgomery A; Khangure N; Williams A; Jacobs I
    Wilderness Environ Med; 2007; 18(3):218-21. PubMed ID: 17896842
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Hypothermia and afterdrop following open water swimming: the Alcatraz/San Francisco Swim Study.
    Nuckton TJ; Claman DM; Goldreich D; Wendt FC; Nuckton JG
    Am J Emerg Med; 2000 Oct; 18(6):703-7. PubMed ID: 11043627
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Infrared ear thermometry in water-related accidents-not a good choice.
    Muth CM; Shank E; Hauser B; Radermacher P; Groger M; Ehrmann U
    J Emerg Med; 2010 May; 38(4):417-21. PubMed ID: 18439786
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Can ear temperature measurement be used in a hospital?].
    Nordås TG; Leiren S; Hansen KS
    Tidsskr Nor Laegeforen; 2005 Oct; 125(20):2763-5. PubMed ID: 16244675
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparing mercury-in-glass, tympanic and disposable thermometers in measuring body temperature in healthy young people.
    Khorshid L; Eşer I; Zaybak A; Yapucu U
    J Clin Nurs; 2005 Apr; 14(4):496-500. PubMed ID: 15807757
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy of digital tympanic, oral, axillary, and rectal thermometers compared with standard rectal mercury thermometers.
    Jensen BN; Jensen FS; Madsen SN; Løssl K
    Eur J Surg; 2000 Nov; 166(11):848-51. PubMed ID: 11097149
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Temperature measurement: comparison of non-invasive methods used in adult critical care.
    Farnell S; Maxwell L; Tan S; Rhodes A; Philips B
    J Clin Nurs; 2005 May; 14(5):632-9. PubMed ID: 15840078
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Hypothermia is a significant medical risk of mass participation long-distance open water swimming.
    Brannigan D; Rogers IR; Jacobs I; Montgomery A; Williams A; Khangure N
    Wilderness Environ Med; 2009; 20(1):14-8. PubMed ID: 19364182
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Measurement accuracy of fever by tympanic and axillary thermometry.
    Devrim I; Kara A; Ceyhan M; Tezer H; Uludağ AK; Cengiz AB; Yiğitkanl I; Seçmeer G
    Pediatr Emerg Care; 2007 Jan; 23(1):16-9. PubMed ID: 17228215
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Temperature measurement in critically ill adults: a comparison of tympanic and oral methods.
    Giuliano KK; Giuliano AJ; Scott SS; MacLachlan E; Pysznik E; Elliot S; Woytowicz D
    Am J Crit Care; 2000 Jul; 9(4):254-61. PubMed ID: 10888148
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Infrared temperature measurement in the ear canal with the DIATEK 9000 Instatemp and the DIATEK 9000 Thermoguide. Comparison with methods of temperature measurement in other body parts].
    Fritz U; Rohrberg M; Lange C; Weyland W; Bräuer A; Braun U
    Anaesthesist; 1996 Nov; 45(11):1059-66. PubMed ID: 9012301
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Usefulness of an earphone-type infrared tympanic thermometer for intraoperative core temperature monitoring].
    Hayase T; Yamakage M; Kiya T; Satoh J; Namiki A
    Masui; 2007 Apr; 56(4):459-63. PubMed ID: 17441460
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Infrared tympanic thermometry--worse than reported?].
    Fremstad ML; Holden GM; Anke AG; Stanghelle JK
    Tidsskr Nor Laegeforen; 1993 Sep; 113(21):2708-10. PubMed ID: 8266296
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Axillary and tympanic membrane temperature measurements are unreliable early after cardiopulmonary bypass.
    Khan TA; Vohra HA; Paul S; Rosin MD; Patel RL
    Eur J Anaesthesiol; 2006 Jul; 23(7):551-4. PubMed ID: 16438760
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Infrared tympanic thermography as a substitute for a probe in the evaluation of ear temperature for post-mortem interval determination: a pilot study.
    Cattaneo C; Di Giancamillo A; Campari O; Orthmann N; Martrille L; Domeneghini C; Jouineau C; Baccino E
    J Forensic Leg Med; 2009 May; 16(4):215-7. PubMed ID: 19329079
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accuracy of Tympanic Temperature Measurement in Firefighters Completing a Simulated Structural Firefighting Task.
    Keene T; Brearley M; Bowen B; Walker A
    Prehosp Disaster Med; 2015 Oct; 30(5):461-5. PubMed ID: 26451779
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Detection and management of hypothermia at a large outdoor endurance event in the United kingdom.
    Bhangu A; Parmar R
    Wilderness Environ Med; 2010 Jun; 21(2):141-5. PubMed ID: 20591378
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Validity of the tympanic infrared thermometer in geriatric inpatients].
    Baeyens H; De Dobbeleer G; Baeyens JP
    Tijdschr Gerontol Geriatr; 2001 Oct; 32(5):206-9. PubMed ID: 11732370
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of tympanic and oral temperatures in surgical patients.
    Erickson RS; Yount ST
    Nurs Res; 1991; 40(2):90-3. PubMed ID: 2003080
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Impact of operator technique and device on infrared emission detection tympanic thermometry.
    Terndrup TE; Rajk J
    J Emerg Med; 1992; 10(6):683-7. PubMed ID: 1491149
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 20.