These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
187 related articles for article (PubMed ID: 17897497)
1. Effects of bur wear during implant site preparation: an in vitro study. Scarano A; Carinci F; Quaranta A; Di Iorio D; Assenza B; Piattelli A Int J Immunopathol Pharmacol; 2007; 20(1 Suppl 1):23-6. PubMed ID: 17897497 [TBL] [Abstract][Full Text] [Related]
2. Infrared thermographic evaluation of temperature modifications induced during implant site preparation with cylindrical versus conical drills. Scarano A; Piattelli A; Assenza B; Carinci F; Di Donato L; Romani GL; Merla A Clin Implant Dent Relat Res; 2011 Dec; 13(4):319-23. PubMed ID: 19681941 [TBL] [Abstract][Full Text] [Related]
3. In Vitro Assessment with the Infrared Thermometer of Temperature Differences Generated During Implant Site Preparation: The Traditional Technique Versus the Single-Drill Technique. Lucchiari N; Frigo AC; Stellini E; Coppe M; Berengo M; Bacci C Clin Implant Dent Relat Res; 2016 Feb; 18(1):182-91. PubMed ID: 25040939 [TBL] [Abstract][Full Text] [Related]
4. Heat generation during implant site preparation: an in vitro study. Cordioli G; Majzoub Z Int J Oral Maxillofac Implants; 1997; 12(2):186-93. PubMed ID: 9109268 [TBL] [Abstract][Full Text] [Related]
5. Thermal changes and drill wear in bovine bone during implant site preparation. A comparative in vitro study: twisted stainless steel and ceramic drills. Oliveira N; Alaejos-Algarra F; Mareque-Bueno J; Ferrés-Padró E; Hernández-Alfaro F Clin Oral Implants Res; 2012 Aug; 23(8):963-9. PubMed ID: 21806686 [TBL] [Abstract][Full Text] [Related]
6. The influence of drill length and irrigation system on heat production during osteotomy preparation for dental implants: an ex vivo study. Gehrke SA; Aramburú Júnior JS; Pérez-Albacete Martínez C; Ramirez Fernandez MP; Maté Sánchez de Val JE; Calvo-Guirado JL Clin Oral Implants Res; 2018 Jul; 29(7):772-778. PubMed ID: 27041138 [TBL] [Abstract][Full Text] [Related]
7. The influence of drill wear on cutting efficiency and heat production during osteotomy preparation for dental implants: a study of drill durability. Ercoli C; Funkenbusch PD; Lee HJ; Moss ME; Graser GN Int J Oral Maxillofac Implants; 2004; 19(3):335-49. PubMed ID: 15214217 [TBL] [Abstract][Full Text] [Related]
8. Temperature changes in bovine mandibular bone during implant site preparation: an assessment using infra-red thermography. Benington IC; Biagioni PA; Crossey PJ; Hussey DL; Sheridan S; Lamey PJ J Dent; 1996 Jul; 24(4):263-7. PubMed ID: 8783531 [TBL] [Abstract][Full Text] [Related]
9. Heat production by 3 implant drill systems after repeated drilling and sterilization. Chacon GE; Bower DL; Larsen PE; McGlumphy EA; Beck FM J Oral Maxillofac Surg; 2006 Feb; 64(2):265-9. PubMed ID: 16413899 [TBL] [Abstract][Full Text] [Related]
10. Effect of surgical drill guide and irrigans temperature on thermal bone changes during drilling implant sites - thermographic analysis on bovine ribs. Marković A; Lazić Z; Mišić T; Šćepanović M; Todorović A; Thakare K; Janjić B; Vlahović Z; Glišić M Vojnosanit Pregl; 2016 Aug; 73(8):744-50. PubMed ID: 29328609 [TBL] [Abstract][Full Text] [Related]
11. Slow drilling speeds for single-drill implant bed preparation. Experimental in vitro study. Delgado-Ruiz RA; Velasco Ortega E; Romanos GE; Gerhke S; Newen I; Calvo-Guirado JL Clin Oral Investig; 2018 Jan; 22(1):349-359. PubMed ID: 28434045 [TBL] [Abstract][Full Text] [Related]
13. Thermal effects of various drill materials during implant site preparation-Ceramic vs. stainless steel drills: A comparative in vitro study in a standardised bovine bone model. Tur D; Giannis K; Unger E; Mittlböck M; Rausch-Fan X; Strbac GD Clin Oral Implants Res; 2021 Feb; 32(2):154-166. PubMed ID: 33220104 [TBL] [Abstract][Full Text] [Related]
14. Drilling- and withdrawing-related thermal effects of implant site preparation for ceramic and stainless steel twist drills in standardized bovine bone. Tur D; Giannis K; Unger E; Mittlböck M; Rausch-Fan X; Strbac GD Clin Implant Dent Relat Res; 2023 Feb; 25(1):152-165. PubMed ID: 36369670 [TBL] [Abstract][Full Text] [Related]
15. Effect of irrigation and stainless steel drills on dental implant bed heat generation. Bullon B; Bueno EF; Herrero M; Fernandez-Palacin A; Rios JV; Bullon P; Gil FJ J Mater Sci Mater Med; 2015 Feb; 26(2):75. PubMed ID: 25631272 [TBL] [Abstract][Full Text] [Related]
16. Thermal effects of a combined irrigation method during implant site drilling. A standardized in vitro study using a bovine rib model. Strbac GD; Unger E; Donner R; Bijak M; Watzek G; Zechner W Clin Oral Implants Res; 2014 Jun; 25(6):665-74. PubMed ID: 23009204 [TBL] [Abstract][Full Text] [Related]
17. Improved Dental Implant Drill Durability and Performance Using Heat and Wear Resistant Protective Coatings. Er N; Alkan A; Ilday S; Bengu E J Oral Implantol; 2018 Jun; 44(3):168-175. PubMed ID: 29498904 [TBL] [Abstract][Full Text] [Related]
18. Effect of the Drilling Technique on Heat Generation During Osteotomy Preparation for Wide-Diameter Implants. El-Kholey KE; Elkomy A Implant Dent; 2016 Dec; 25(6):825-828. PubMed ID: 27540847 [TBL] [Abstract][Full Text] [Related]
19. Temperature change in pig rib bone during implant site preparation by low-speed drilling. Kim SJ; Yoo J; Kim YS; Shin SW J Appl Oral Sci; 2010; 18(5):522-7. PubMed ID: 21085811 [TBL] [Abstract][Full Text] [Related]
20. Descriptive study of the longevity of dental implant surgery drills. Allsobrook OF; Leichter J; Holborrow D; Swain M Clin Implant Dent Relat Res; 2011 Sep; 13(3):244-54. PubMed ID: 22106473 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]