1234 related articles for article (PubMed ID: 17902631)
1. Mass spectrometric techniques for label-free high-throughput screening in drug discovery.
Roddy TP; Horvath CR; Stout SJ; Kenney KL; Ho PI; Zhang JH; Vickers C; Kaushik V; Hubbard B; Wang YK
Anal Chem; 2007 Nov; 79(21):8207-13. PubMed ID: 17902631
[TBL] [Abstract][Full Text] [Related]
2. A generic fast solid-phase extraction high-performance liquid chromatography/mass spectrometry method for high-throughput drug discovery.
Gao L; Cheng X; Zhang J; Burns DJ
Rapid Commun Mass Spectrom; 2007; 21(21):3497-504. PubMed ID: 17922486
[TBL] [Abstract][Full Text] [Related]
3. Strategies for bioanalysis of an oligonucleotide class macromolecule from rat plasma using liquid chromatography-tandem mass spectrometry.
Zhang G; Lin J; Srinivasan K; Kavetskaia O; Duncan JN
Anal Chem; 2007 May; 79(9):3416-24. PubMed ID: 17394287
[TBL] [Abstract][Full Text] [Related]
4. Simultaneous LC-MS/MS quantitation of a highly hydrophobic pharmaceutical compound and its metabolite in urine using online monolithic phase-based extraction.
Xu RN; Boyd B; Rieser MJ; El-Shourbagy TA
J Sep Sci; 2007 Nov; 30(17):2943-9. PubMed ID: 17924587
[TBL] [Abstract][Full Text] [Related]
5. Addressing the analytical throughput challenges in ADME screening using rapid ultra-performance liquid chromatography/tandem mass spectrometry methodologies.
Plumb RS; Potts WB; Rainville PD; Alden PG; Shave DH; Baynham G; Mazzeo JR
Rapid Commun Mass Spectrom; 2008 Jul; 22(14):2139-52. PubMed ID: 18543375
[TBL] [Abstract][Full Text] [Related]
6. Assay development and screening of human DGAT1 inhibitors with an LC/MS-based assay: application of mass spectrometry for large-scale primary screening.
Zhang JH; Roddy TP; Ho PI; Horvath CR; Vickers C; Stout S; Hubbard B; Wang YK; Hill WA; Bojanic D
J Biomol Screen; 2010 Jul; 15(6):695-702. PubMed ID: 20484097
[TBL] [Abstract][Full Text] [Related]
7. Higher-throughput screening for Caco-2 permeability utilizing a multiple sprayer liquid chromatography/tandem mass spectrometry system.
Fung EN; Chu I; Li C; Liu T; Soares A; Morrison R; Nomeir AA
Rapid Commun Mass Spectrom; 2003; 17(18):2147-52. PubMed ID: 12955746
[TBL] [Abstract][Full Text] [Related]
8. Rapid screening for bisbibenzyls in bryophyte crude extracts using liquid chromatography/tandem mass spectrometry.
Xing J; Xie C; Qu J; Guo H; Lv B; Lou H
Rapid Commun Mass Spectrom; 2007; 21(15):2467-76. PubMed ID: 17610245
[TBL] [Abstract][Full Text] [Related]
9. Ultrahigh-pressure dual online solid phase extraction/capillary reverse-phase liquid chromatography/tandem mass spectrometry (DO-SPE/cRPLC/MS/MS): a versatile separation platform for high-throughput and highly sensitive proteomic analyses.
Min HK; Hyung SW; Shin JW; Nam HS; Ahn SH; Jung HJ; Lee SW
Electrophoresis; 2007 Mar; 28(6):1012-21. PubMed ID: 17309056
[TBL] [Abstract][Full Text] [Related]
10. Fully automated analysis of beta-lactams in bovine milk by online solid phase extraction-liquid chromatography-electrospray-tandem mass spectrometry.
Kantiani L; Farré M; Sibum M; Postigo C; López de Alda M; Barceló D
Anal Chem; 2009 Jun; 81(11):4285-95. PubMed ID: 19402673
[TBL] [Abstract][Full Text] [Related]
11. An automated SPE/LC/MS/MS method for the analysis of cocaine and metabolites in whole blood.
Jagerdeo E; Montgomery MA; Lebeau MA; Sibum M
J Chromatogr B Analyt Technol Biomed Life Sci; 2008 Oct; 874(1-2):15-20. PubMed ID: 18829399
[TBL] [Abstract][Full Text] [Related]
12. A broad-spectrum equine urine screening method for free and enzyme-hydrolysed conjugated drugs with ultra performance liquid chromatography/tandem mass spectrometry.
Wong CH; Tang FP; Wan TS
Anal Chim Acta; 2011 Jul; 697(1-2):48-60. PubMed ID: 21641418
[TBL] [Abstract][Full Text] [Related]
13. Development of a high-throughput online solid-phase extraction/tandem mass spectrometry method for cytochrome P450 inhibition screening.
Lim KB; Ozbal CC; Kassel DB
J Biomol Screen; 2010 Apr; 15(4):447-52. PubMed ID: 20208033
[TBL] [Abstract][Full Text] [Related]
14. Automatic mass spectrometry method development for drug discovery: application in metabolic stability assays.
Chovan LE; Black-Schaefer C; Dandliker PJ; Lau YY
Rapid Commun Mass Spectrom; 2004; 18(24):3105-12. PubMed ID: 15565734
[TBL] [Abstract][Full Text] [Related]
15. A high throughput metabolic stability screening workflow with automated assessment of data quality in pharmaceutical industry.
Xu R; Manuel M; Cramlett J; Kassel DB
J Chromatogr A; 2010 Mar; 1217(10):1616-25. PubMed ID: 20132940
[TBL] [Abstract][Full Text] [Related]
16. Ultrafast mass spectrometry based bioanalytical method for digoxin supporting an in vitro P-glycoprotein (P-gp) inhibition screen.
Wagner AD; Kolb JM; Ozbal CC; Herbst JJ; Olah TV; Weller HN; Zvyaga TA; Shou WZ
Rapid Commun Mass Spectrom; 2011 May; 25(9):1231-40. PubMed ID: 21488121
[TBL] [Abstract][Full Text] [Related]
17. Recent advances in high-throughput quantitative bioanalysis by LC-MS/MS.
Xu RN; Fan L; Rieser MJ; El-Shourbagy TA
J Pharm Biomed Anal; 2007 Jun; 44(2):342-55. PubMed ID: 17360141
[TBL] [Abstract][Full Text] [Related]
18. Development of a pressurized liquid extraction-solid-phase extraction followed by liquid chromatography-electrospray ionization tandem mass spectrometry method for the quantitative determination of benzoxazolinones and their degradation products in agricultural soil.
Villagrasa M; Guillamón M; Navarro A; Eljarrat E; Barceló D
J Chromatogr A; 2008 Feb; 1179(2):190-7. PubMed ID: 18096177
[TBL] [Abstract][Full Text] [Related]
19. Streamlined system for purifying and quantifying a diverse library of compounds and the effect of compound concentration measurements on the accurate interpretation of biological assay results.
Popa-Burke IG; Issakova O; Arroway JD; Bernasconi P; Chen M; Coudurier L; Galasinski S; Jadhav AP; Janzen WP; Lagasca D; Liu D; Lewis RS; Mohney RP; Sepetov N; Sparkman DA; Hodge CN
Anal Chem; 2004 Dec; 76(24):7278-87. PubMed ID: 15595870
[TBL] [Abstract][Full Text] [Related]
20. An automated screening method for drugs and toxic compounds in human serum and urine using liquid chromatography-tandem mass spectrometry.
Sturm S; Hammann F; Drewe J; Maurer HH; Scholer A
J Chromatogr B Analyt Technol Biomed Life Sci; 2010 Oct; 878(28):2726-32. PubMed ID: 20846915
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]