These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
262 related articles for article (PubMed ID: 17902942)
1. Relative detection efficiency of back- and front-illuminated charge-coupled device cameras for X-rays between 1 keV and 18 keV. Szlachetko J; Dousse JC; Hoszowska J; Berset M; Cao W; Szlachetko M; Kavcic M Rev Sci Instrum; 2007 Sep; 78(9):093102. PubMed ID: 17902942 [TBL] [Abstract][Full Text] [Related]
2. Front-illuminated versus back-illuminated photon-counting CCD-based gamma camera: important consequences for spatial resolution and energy resolution. Heemskerk JW; Westra AH; Linotte PM; Ligtvoet KM; Zbijewski W; Beekman FJ Phys Med Biol; 2007 Apr; 52(8):N149-62. PubMed ID: 17404450 [TBL] [Abstract][Full Text] [Related]
3. Calibration and characterization of single photon counting cameras for short-pulse laser experiments. Maddox BR; Park HS; Remington BA; McKernan M Rev Sci Instrum; 2008 Oct; 79(10):10E924. PubMed ID: 19044579 [TBL] [Abstract][Full Text] [Related]
4. Development of a high-efficiency high-resolution particle-induced x-ray emission system for chemical state analysis of environmental samples. Hasegawa J; Tada T; Oguri Y; Hayashi M; Toriyama T; Kawabata T; Masai K Rev Sci Instrum; 2007 Jul; 78(7):073105. PubMed ID: 17672753 [TBL] [Abstract][Full Text] [Related]
5. High resolution flat crystal spectrometer for the Shanghai EBIT. Xiao J; Gao Y; Zhang X; Lu D; Hu W; Gao M; Chen W; Zou Y Rev Sci Instrum; 2008 Sep; 79(9):093101. PubMed ID: 19044398 [TBL] [Abstract][Full Text] [Related]
6. Absolute determination of charge-coupled device quantum detection efficiency using Si K-edge x-ray absorption fine structure. Dunn J; Steel AB Rev Sci Instrum; 2012 Oct; 83(10):10E120. PubMed ID: 23126942 [TBL] [Abstract][Full Text] [Related]
7. Recognition of pigment layers in illuminated manuscripts by means of Kalpha/Kbeta and Lalpha/Lbeta ratios of characteristic X-rays. Trojek T; Cechák T; Musílek L Appl Radiat Isot; 2010; 68(4-5):871-4. PubMed ID: 19833527 [TBL] [Abstract][Full Text] [Related]
8. Photon-counting versus an integrating CCD-based gamma camera: important consequences for spatial resolution. Beekman FJ; de Vree GA Phys Med Biol; 2005 Jun; 50(12):N109-19. PubMed ID: 15930598 [TBL] [Abstract][Full Text] [Related]
9. Detection of atomic and molecular mega-electron-volt projectiles using an x-ray charged coupled device camera. Chabot M; Martinet G; Béroff K; Pino T; Bouneau S; Genolini B; Grave X; Nguyen K; le Gailliard C; Rosier P; Féraud G; Friha H; Villier B Rev Sci Instrum; 2011 Oct; 82(10):103301. PubMed ID: 22047285 [TBL] [Abstract][Full Text] [Related]
10. Performances of a bent-crystal spectrometer adapted to resonant x-ray emission measurements on gas-phase samples. Journel L; El Khoury L; Marin T; Guillemin R; Carniato S; Avila A; Delaunay R; Hague CF; Simon M Rev Sci Instrum; 2009 Sep; 80(9):093105. PubMed ID: 19791930 [TBL] [Abstract][Full Text] [Related]
11. Quantum efficiency measurement of an x-ray charge-coupled device by means of an x-ray generator monochromatized over the 0.2-1.2 keV spectral region. Hubert S; Boubault F Appl Opt; 2018 Oct; 57(28):8228-8235. PubMed ID: 30461772 [TBL] [Abstract][Full Text] [Related]
12. Quantum efficiency measurements of an x-ray charge-coupled device in the 2-10 keV spectral region by means of a double crystal monochromator coupled to an x-ray tube. Hubert S; Prévot V Appl Opt; 2014 Dec; 53(34):8078-85. PubMed ID: 25607966 [TBL] [Abstract][Full Text] [Related]
13. A micro-machined retro-reflector for improving light yield in ultra-high-resolution gamma cameras. Heemskerk JW; Korevaar MA; Kreuger R; Ligtvoet CM; Schotanus P; Beekman FJ Phys Med Biol; 2009 May; 54(10):3003-14. PubMed ID: 19387099 [TBL] [Abstract][Full Text] [Related]
14. A broadband superconducting detector suitable for use in large arrays. Day PK; LeDuc HG; Mazin BA; Vayonakis A; Zmuidzinas J Nature; 2003 Oct; 425(6960):817-21. PubMed ID: 14574407 [TBL] [Abstract][Full Text] [Related]
15. Recent developments in X-ray imaging with micrometer spatial resolution. Martin T; Koch A J Synchrotron Radiat; 2006 Mar; 13(Pt 2):180-94. PubMed ID: 16495618 [TBL] [Abstract][Full Text] [Related]
16. Flat field anomalies in an x-ray charge coupled device camera measured using a Manson x-ray source. Haugh MJ; Schneider MB Rev Sci Instrum; 2008 Oct; 79(10):10E925. PubMed ID: 19044580 [TBL] [Abstract][Full Text] [Related]
17. An enhanced high-resolution EMCCD-based gamma camera using SiPM side detection. Heemskerk JW; Korevaar MA; Huizenga J; Kreuger R; Schaart DR; Goorden MC; Beekman FJ Phys Med Biol; 2010 Nov; 55(22):6773-84. PubMed ID: 21030743 [TBL] [Abstract][Full Text] [Related]
18. 200-mm segmented cylindrical figured crystal for von Hamos x-ray spectrometer. Rani S; Lee JH; Kim Y Rev Sci Instrum; 2020 Jan; 91(1):013101. PubMed ID: 32012639 [TBL] [Abstract][Full Text] [Related]
19. Imaging performance of the hybrid pixel detectors XPAD3-S. Brunner FC; Clemens JC; Hemmer C; Morel C Phys Med Biol; 2009 Mar; 54(6):1773-89. PubMed ID: 19258683 [TBL] [Abstract][Full Text] [Related]