266 related articles for article (PubMed ID: 17902942)
21. Multi-scale algorithm for improved scintillation detection in a CCD-based gamma camera.
Korevaar MA; Heemskerk JW; Goorden MC; Beekman FJ
Phys Med Biol; 2009 Feb; 54(4):831-42. PubMed ID: 19141886
[TBL] [Abstract][Full Text] [Related]
22. The x-ray calibration facility of the laser integration line in the 0.9-10 keV range: the high energy x-ray source and some applications.
Hubert S; Dubois JL; Gontier D; Lidove G; Reverdin C; Soullié G; Stemmler P; Villette B
Rev Sci Instrum; 2010 May; 81(5):053501. PubMed ID: 20515133
[TBL] [Abstract][Full Text] [Related]
23. Scaling studies with the dual crystal spectrometer at the OMEGA-EP laser facility.
Szabo CI; Workman J; Flippo K; Feldman U; Seely JF; Hudson LT; Henins A
Rev Sci Instrum; 2010 Oct; 81(10):10E320. PubMed ID: 21034018
[TBL] [Abstract][Full Text] [Related]
24. The use and characterization of a backilluminated charge-coupled device in investigations of pulsed x-ray and radiation sources.
Fullagar W; Uhlig J; Walczak M; Canton S; Sundström V
Rev Sci Instrum; 2008 Oct; 79(10):103302. PubMed ID: 19044707
[TBL] [Abstract][Full Text] [Related]
25. Broadband, high dynamics and high resolution charge coupled device-based spectrometer in dynamic mode for multi-keV repetitive x-ray sources.
Fourment C; Arazam N; Bonte C; Caillaud T; Descamps D; Dorchies F; Harmand M; Hulin S; Petit S; Santos JJ
Rev Sci Instrum; 2009 Aug; 80(8):083505. PubMed ID: 19725653
[TBL] [Abstract][Full Text] [Related]
26. Analysis of wrapped or cased object by a hand-held X-ray fluorescence spectrometer.
Ida H; Kawai J
Forensic Sci Int; 2005 Jul; 151(2-3):267-72. PubMed ID: 15939161
[TBL] [Abstract][Full Text] [Related]
27. Performance Model for High Spatial Resolution Csl Scintillator Screens Coupled to CCD Detectors.
Castelli CM; Allinson NM
J Xray Sci Technol; 1995 Jan; 5(2):207-20. PubMed ID: 21307487
[TBL] [Abstract][Full Text] [Related]
28. PINK: a tender X-ray beamline for X-ray emission spectroscopy.
Peredkov S; Pereira N; Grötzsch D; Hendel S; Wallacher D; DeBeer S
J Synchrotron Radiat; 2024 May; 31(Pt 3):622-634. PubMed ID: 38662410
[TBL] [Abstract][Full Text] [Related]
29. Energy resolved soft x-ray imaging using a charge coupled device camera for long pulse discharges in the Large Helical Device.
Suzuki C; Ida K; Kobuchi T; Yoshinuma M
Rev Sci Instrum; 2008 Oct; 79(10):10E929. PubMed ID: 19044584
[TBL] [Abstract][Full Text] [Related]
30. Performance of the EBIT calorimeter spectrometer.
Porter FS; Gygax J; Kelley RL; Kilbourne CA; King JM; Beiersdorfer P; Brown GV; Thorn DB; Kahn SM
Rev Sci Instrum; 2008 Oct; 79(10):10E307. PubMed ID: 19044469
[TBL] [Abstract][Full Text] [Related]
31. Efficiency calibrations of cylindrically bent transmission crystals in the 20 to 80 keV x-ray energy range.
Szabo CI; Feldman U; Seltzer S; Hudson LT; O'Brien M; Park HS; Seely JF
Opt Lett; 2011 Apr; 36(8):1335-7. PubMed ID: 21499348
[TBL] [Abstract][Full Text] [Related]
32. Invited article: the fast readout low noise camera as a versatile x-ray detector for time resolved dispersive extended x-ray absorption fine structure and diffraction studies of dynamic problems in materials science, chemistry, and catalysis.
Labiche JC; Mathon O; Pascarelli S; Newton MA; Ferre GG; Curfs C; Vaughan G; Homs A; Carreiras DF
Rev Sci Instrum; 2007 Sep; 78(9):091301. PubMed ID: 17902940
[TBL] [Abstract][Full Text] [Related]
33. Detective quantum efficiency, modulation transfer function and energy resolution comparison between CdTe and silicon sensors bump-bonded to XPAD3S.
Medjoubi K; Bucaille T; Hustache S; Bérar JF; Boudet N; Clemens JC; Delpierre P; Dinkespiler B
J Synchrotron Radiat; 2010 Jul; 17(4):486-95. PubMed ID: 20567081
[TBL] [Abstract][Full Text] [Related]
34. Laboratory-based micro-X-ray fluorescence setup using a von Hamos crystal spectrometer and a focused beam X-ray tube.
Kayser Y; Błachucki W; Dousse JC; Hoszowska J; Neff M; Romano V
Rev Sci Instrum; 2014 Apr; 85(4):043101. PubMed ID: 24784587
[TBL] [Abstract][Full Text] [Related]
35. Spectrometer for lanthanides' K x-ray fluorescence.
Sakurai K; Mizusawa M; Terada Y
Rev Sci Instrum; 2007 Jun; 78(6):066108. PubMed ID: 17614652
[TBL] [Abstract][Full Text] [Related]
36. Misidentification of major constituents by automatic qualitative energy dispersive X-ray microanalysis: a problem that threatens the credibility of the analytical community.
Newbury DE
Microsc Microanal; 2005 Dec; 11(6):545-61. PubMed ID: 17481333
[TBL] [Abstract][Full Text] [Related]
37. A fast, direct x-ray detection charge-coupled device.
Denes P; Doering D; Padmore HA; Walder JP; Weizeorick J
Rev Sci Instrum; 2009 Aug; 80(8):083302. PubMed ID: 19725646
[TBL] [Abstract][Full Text] [Related]
38. High-energy, high-resolution x-ray imaging on the Trident short-pulse laser facility.
Workman J; Cobble J; Flippo K; Gautier DC; Letzring S
Rev Sci Instrum; 2008 Oct; 79(10):10E905. PubMed ID: 19044560
[TBL] [Abstract][Full Text] [Related]
39. Valence-electron configuration of Ti and Ni in TixNi1-x alloys from Kbeta-to-Kalpha X-ray intensity ratio studies.
Han I; Demir L
Appl Radiat Isot; 2010 Jun; 68(6):1035-9. PubMed ID: 20153209
[TBL] [Abstract][Full Text] [Related]
40. Development of two-grating spectrometer for the charge exchange spectroscopy system on KSTAR.
Lee H; Song EJ; Park YD; Oh SG; Ko WH
Rev Sci Instrum; 2011 Jun; 82(6):063510. PubMed ID: 21721694
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]