263 related articles for article (PubMed ID: 17902972)
1. A high-precision five-degree-of-freedom measurement system based on laser collimator and interferometry techniques.
Kuang C; Hong E; Ni J
Rev Sci Instrum; 2007 Sep; 78(9):095105. PubMed ID: 17902972
[TBL] [Abstract][Full Text] [Related]
2. A laser interferometer for measuring straightness and its position based on heterodyne interferometry.
Chen B; Zhang E; Yan L; Li C; Tang W; Feng Q
Rev Sci Instrum; 2009 Nov; 80(11):115113. PubMed ID: 19947763
[TBL] [Abstract][Full Text] [Related]
3. Laser straightness interferometer system with rotational error compensation and simultaneous measurement of six degrees of freedom error parameters.
Chen B; Xu B; Yan L; Zhang E; Liu Y
Opt Express; 2015 Apr; 23(7):9052-73. PubMed ID: 25968740
[TBL] [Abstract][Full Text] [Related]
4. Development of a three-degree-of-freedom laser linear encoder for error measurement of a high precision stage.
Huang HL; Liu CH; Jywe WY; Wang MS; Fang TH
Rev Sci Instrum; 2007 Jun; 78(6):066103. PubMed ID: 17614647
[TBL] [Abstract][Full Text] [Related]
5. Laser homodyne straightness interferometer with simultaneous measurement of six degrees of freedom motion errors for precision linear stage metrology.
Lou Y; Yan L; Chen B; Zhang S
Opt Express; 2017 Mar; 25(6):6805-6821. PubMed ID: 28381023
[TBL] [Abstract][Full Text] [Related]
6. High resolution heterodyne interferometer without detectable periodic nonlinearity.
Joo KN; Ellis JD; Buice ES; Spronck JW; Schmidt RH
Opt Express; 2010 Jan; 18(2):1159-65. PubMed ID: 20173939
[TBL] [Abstract][Full Text] [Related]
7. Laser interferometric system for six-axis motion measurement.
Zhang Z; Menq CH
Rev Sci Instrum; 2007 Aug; 78(8):083107. PubMed ID: 17764313
[TBL] [Abstract][Full Text] [Related]
8. Development of a compact, fiber-coupled, six degree-of-freedom measurement system for precision linear stage metrology.
Yu X; Gillmer SR; Woody SC; Ellis JD
Rev Sci Instrum; 2016 Jun; 87(6):065109. PubMed ID: 27370499
[TBL] [Abstract][Full Text] [Related]
9. Design of a Measurement System for Six-Degree-of-Freedom Geometric Errors of a Linear Guide of a Machine Tool.
Liu CS; Lai JJ; Luo YT
Sensors (Basel); 2018 Dec; 19(1):. PubMed ID: 30577462
[TBL] [Abstract][Full Text] [Related]
10. Development of a simple system for simultaneously measuring 6DOF geometric motion errors of a linear guide.
Qibo F; Bin Z; Cunxing C; Cuifang K; Yusheng Z; Fenglin Y
Opt Express; 2013 Nov; 21(22):25805-19. PubMed ID: 24216807
[TBL] [Abstract][Full Text] [Related]
11. Five-degrees-of-freedom measurement system based on a monolithic prism and phase-sensitive detection technique.
Huang P; Li Y; Wei H; Ren L; Zhao S
Appl Opt; 2013 Sep; 52(26):6607-15. PubMed ID: 24085139
[TBL] [Abstract][Full Text] [Related]
12. A heterodyne straightness and displacement measuring interferometer with laser beam drift compensation for long-travel linear stage metrology.
Chen B; Cheng L; Yan L; Zhang E; Lou Y
Rev Sci Instrum; 2017 Mar; 88(3):035114. PubMed ID: 28372378
[TBL] [Abstract][Full Text] [Related]
13. A Targetless Method for Simultaneously Measuring Three-Degree-of-Freedom Angular Motion Errors with Digital Speckle Pattern Interferometry.
Shi L; Wu S; Yan M; Niu H
Sensors (Basel); 2023 Mar; 23(7):. PubMed ID: 37050453
[TBL] [Abstract][Full Text] [Related]
14. A cam-displacement transducer device for measuring small two-degree of freedom inter-component motion in a prosthesis.
Twiste M; Rithalia SV; Kenney L
Med Eng Phys; 2004 May; 26(4):335-40. PubMed ID: 15121059
[TBL] [Abstract][Full Text] [Related]
15. Low cost, compact 4-DOF measurement system with active compensation of beam angular drift error.
Huang Y; Fan KC; Sun W; Liu S
Opt Express; 2018 Jun; 26(13):17185-17198. PubMed ID: 30119533
[TBL] [Abstract][Full Text] [Related]
16. Design of a Measurement System for Simultaneously Measuring Six-Degree-Of-Freedom Geometric Errors of a Long Linear Stage.
Liu CS; Pu YF; Chen YT; Luo YT
Sensors (Basel); 2018 Nov; 18(11):. PubMed ID: 30423845
[TBL] [Abstract][Full Text] [Related]
17. Modified Fabry-Perot interferometer for displacement measurement in ultra large measuring range.
Chang CP; Tung PC; Shyu LH; Wang YC; Manske E
Rev Sci Instrum; 2013 May; 84(5):053105. PubMed ID: 23742530
[TBL] [Abstract][Full Text] [Related]
18. Heterodyne grating interferometer based on a quasi-common-optical-path configuration for a two-degrees-of-freedom straightness measurement.
Lee JY; Hsieh HL; Lerondel G; Deturche R; Lu MP; Chen JC
Appl Opt; 2011 Mar; 50(9):1272-9. PubMed ID: 21460999
[TBL] [Abstract][Full Text] [Related]
19. A heterodyne interferometer for angle metrology.
Hahn I; Weilert M; Wang X; Goullioud R
Rev Sci Instrum; 2010 Apr; 81(4):045103. PubMed ID: 20441364
[TBL] [Abstract][Full Text] [Related]
20. Calibration of projector lens distortions.
Hüe F; Johnson CL; Lartigue-Korinek S; Wang G; Buseck PR; Hÿtch MJ
J Electron Microsc (Tokyo); 2005 Jun; 54(3):181-90. PubMed ID: 16123065
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]