These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
1048 related articles for article (PubMed ID: 17905578)
1. A novel glucose biosensor based on immobilization of glucose oxidase into multiwall carbon nanotubes-polyelectrolyte-loaded electrospun nanofibrous membrane. Manesh KM; Kim HT; Santhosh P; Gopalan AI; Lee KP Biosens Bioelectron; 2008 Jan; 23(6):771-9. PubMed ID: 17905578 [TBL] [Abstract][Full Text] [Related]
2. Multilayer membranes for glucose biosensing via layer-by-layer assembly of multiwall carbon nanotubes and glucose oxidase. Zhao H; Ju H Anal Biochem; 2006 Mar; 350(1):138-44. PubMed ID: 16430853 [TBL] [Abstract][Full Text] [Related]
3. A novel glucose biosensor based on immobilization of glucose oxidase in chitosan on a glassy carbon electrode modified with gold-platinum alloy nanoparticles/multiwall carbon nanotubes. Kang X; Mai Z; Zou X; Cai P; Mo J Anal Biochem; 2007 Oct; 369(1):71-9. PubMed ID: 17678866 [TBL] [Abstract][Full Text] [Related]
4. Immobilization of glucose oxidase on electrodeposited nickel oxide nanoparticles: direct electron transfer and electrocatalytic activity. Salimi A; Sharifi E; Noorbakhsh A; Soltanian S Biosens Bioelectron; 2007 Jun; 22(12):3146-53. PubMed ID: 17368016 [TBL] [Abstract][Full Text] [Related]
5. Electrodeposition of polypyrrole-multiwalled carbon nanotube-glucose oxidase nanobiocomposite film for the detection of glucose. Tsai YC; Li SC; Liao SW Biosens Bioelectron; 2006 Oct; 22(4):495-500. PubMed ID: 16870421 [TBL] [Abstract][Full Text] [Related]
7. Multilayer assembly of positively charged polyelectrolyte and negatively charged glucose oxidase on a 3D Nafion network for detecting glucose. Chen X; Yan X; Khor KA; Tay BK Biosens Bioelectron; 2007 Jun; 22(12):3256-60. PubMed ID: 17314038 [TBL] [Abstract][Full Text] [Related]
8. Amperometric glucose biosensor based on multilayer films via layer-by-layer self-assembly of multi-wall carbon nanotubes, gold nanoparticles and glucose oxidase on the Pt electrode. Wu BY; Hou SH; Yin F; Zhao ZX; Wang YY; Wang XS; Chen Q Biosens Bioelectron; 2007 Jun; 22(12):2854-60. PubMed ID: 17212983 [TBL] [Abstract][Full Text] [Related]
9. A glucose biosensor based on direct electrochemistry of glucose oxidase immobilized on nitrogen-doped carbon nanotubes. Deng S; Jian G; Lei J; Hu Z; Ju H Biosens Bioelectron; 2009 Oct; 25(2):373-7. PubMed ID: 19683424 [TBL] [Abstract][Full Text] [Related]
10. Supramolecular architecture based on the self-assembling of multiwall carbon nanotubes dispersed in polyhistidine and glucose oxidase: Characterization and analytical applications for glucose biosensing. Dalmasso PR; Pedano ML; Rivas GA Biosens Bioelectron; 2013 Jan; 39(1):76-81. PubMed ID: 22794932 [TBL] [Abstract][Full Text] [Related]
11. A glucose biosensor based on electrodeposition of palladium nanoparticles and glucose oxidase onto Nafion-solubilized carbon nanotube electrode. Lim SH; Wei J; Lin J; Li Q; Kuayou J Biosens Bioelectron; 2005 May; 20(11):2341-6. PubMed ID: 15797337 [TBL] [Abstract][Full Text] [Related]
12. An electrochemical glucose biosensor exploiting a polyaniline grafted multiwalled carbon nanotube/perfluorosulfonate ionomer-silica nanocomposite. Gopalan AI; Lee KP; Ragupathy D; Lee SH; Lee JW Biomaterials; 2009 Oct; 30(30):5999-6005. PubMed ID: 19674780 [TBL] [Abstract][Full Text] [Related]
13. An amperometric biosensor based on a composite of single-walled carbon nanotubes, plasma-polymerized thin film, and an enzyme. Muguruma H; Shibayama Y; Matsui Y Biosens Bioelectron; 2008 Jan; 23(6):827-32. PubMed ID: 17935968 [TBL] [Abstract][Full Text] [Related]
14. Layer-by-layer fabrication and direct electrochemistry of glucose oxidase on single wall carbon nanotubes. Zhang J; Feng M; Tachikawa H Biosens Bioelectron; 2007 Jun; 22(12):3036-41. PubMed ID: 17321126 [TBL] [Abstract][Full Text] [Related]
15. Amperometric glucose biosensor based on layer-by-layer covalent attachment of AMWNTs and IO(4)(-)-oxidized GOx. Sun Y; Wang H; Sun C Biosens Bioelectron; 2008 Sep; 24(1):22-8. PubMed ID: 18440797 [TBL] [Abstract][Full Text] [Related]
16. A biosensor prepared by co-entrapment of a glucose oxidase and a carbon nanotube within an electrochemically deposited redox polymer multilayer. Gao Q; Guo Y; Liu J; Yuan X; Qi H; Zhang C Bioelectrochemistry; 2011 Jun; 81(2):109-13. PubMed ID: 21570925 [TBL] [Abstract][Full Text] [Related]
17. A novel nanobiocomposite based glucose biosensor using neutral red functionalized carbon nanotubes. Shobha Jeykumari DR; Sriman Narayanan S Biosens Bioelectron; 2008 Apr; 23(9):1404-11. PubMed ID: 18294834 [TBL] [Abstract][Full Text] [Related]
18. Bienzymatic glucose biosensor based on co-immobilization of peroxidase and glucose oxidase on a carbon nanotubes electrode. Zhu L; Yang R; Zhai J; Tian C Biosens Bioelectron; 2007 Nov; 23(4):528-35. PubMed ID: 17764922 [TBL] [Abstract][Full Text] [Related]
19. A highly sensitive nonenzymatic glucose sensor based on CuO nanoparticles-modified carbon nanotube electrode. Jiang LC; Zhang WD Biosens Bioelectron; 2010 Feb; 25(6):1402-7. PubMed ID: 19942424 [TBL] [Abstract][Full Text] [Related]
20. Biosensor based on self-assembling acetylcholinesterase on carbon nanotubes for flow injection/amperometric detection of organophosphate pesticides and nerve agents. Liu G; Lin Y Anal Chem; 2006 Feb; 78(3):835-43. PubMed ID: 16448058 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]