8. Study design and rationale of the 'Balloon-Expandable Cobalt Chromium SCUBA Stent versus Self-Expandable COMPLETE-SE Nitinol Stent for the Atherosclerotic ILIAC Arterial Disease (SENS-ILIAC Trial) Trial': study protocol for a randomized controlled trial. Choi WG; Rha SW; Choi CU; Kim EJ; Oh DJ; Cho YH; Park SH; Lee SJ; Hur AY; Ko YG; Park SM; Kim KC; Kim JH; Kim MW; Kim SM; Bae JH; Bong JM; Kang WY; Seo JB; Jung WY; Cho JH; Kim do H; Ahn JH; Kim SH; Jang JY; Trials; 2016 Jun; 17(1):302. PubMed ID: 27344435 [TBL] [Abstract][Full Text] [Related]
9. Influence of stent type on hemodynamic depression after carotid artery stent placement. Diehm N; Katzen BT; Dick F; Kovacs M; Zemel G; Powell A; Samuels S; Benenati JF J Vasc Interv Radiol; 2008 Jan; 19(1):23-30. PubMed ID: 18192464 [TBL] [Abstract][Full Text] [Related]
10. Stenting for carotid artery stenosis: fractures, proposed etiology and the need for surveillance. Ling AJ; Mwipatayi P; Gandhi T; Sieunarine K J Vasc Surg; 2008 Jun; 47(6):1220-6; discussion 1226. PubMed ID: 18440186 [TBL] [Abstract][Full Text] [Related]
11. Outcome of carotid artery stenting at 2 years follow-up: comparison of nitinol open cell versus stainless steel closed cell stent design. MALEUX G; MARRANNES J; HEYE S; DAENENS K; VERHAMME P; THIJS V J Cardiovasc Surg (Torino); 2009 Oct; 50(5):669-75. PubMed ID: 19455089 [TBL] [Abstract][Full Text] [Related]
12. Carotid artery stenting for stenosis following cervical radiotherapy: report of early failure with associated stent fracture. Ross CB; Khoobehi A; Irwin CL; Dattilo JB; Naslund TC Vasc Endovascular Surg; 2009 Dec; 43(6):599-605. PubMed ID: 19640908 [TBL] [Abstract][Full Text] [Related]
14. Cutting balloon angioplasty for carotid in-stent restenosis: case reports and review of the literature. Shah QA; Georgiadis AL; Suri MF; Rodriguez GJ; Qureshi AI J Neuroimaging; 2008 Oct; 18(4):428-32. PubMed ID: 18333838 [TBL] [Abstract][Full Text] [Related]
15. Clinical Results and Mechanical Properties of the Carotid CGUARD Double-Layered Embolic Prevention Stent. Wissgott C; Schmidt W; Brandt-Wunderlich C; Behrens P; Andresen R J Endovasc Ther; 2017 Feb; 24(1):130-137. PubMed ID: 27733689 [TBL] [Abstract][Full Text] [Related]
16. Management of in-sent restenosis after carotid artery stenting in high-risk patients. Zhou W; Lin PH; Bush RL; Peden EK; Guerrero MA; Kougias P; Lumsden AB J Vasc Surg; 2006 Feb; 43(2):305-12. PubMed ID: 16476606 [TBL] [Abstract][Full Text] [Related]
17. Regarding "Patterns of in-stent restenosis after carotid artery stenting: Classification and implications for long term outcome". de Borst GJ; Moll FL J Vasc Surg; 2008 Jun; 47(6):1379-80; author reply 1380. PubMed ID: 18514860 [No Abstract] [Full Text] [Related]
18. Fractured internal carotid artery stent. Nazzal M; Abbas J; Nazzal M; Afridi S; Ritter M Vascular; 2008; 16(3):179-82. PubMed ID: 18674468 [TBL] [Abstract][Full Text] [Related]