379 related articles for article (PubMed ID: 17914750)
1. Validation of the PathFinder neurosurgical robot using a phantom.
Eljamel MS
Int J Med Robot; 2007 Dec; 3(4):372-7. PubMed ID: 17914750
[TBL] [Abstract][Full Text] [Related]
2. The application accuracy of the NeuroMate robot--A quantitative comparison with frameless and frame-based surgical localization systems.
Li QH; Zamorano L; Pandya A; Perez R; Gong J; Diaz F
Comput Aided Surg; 2002; 7(2):90-8. PubMed ID: 12112718
[TBL] [Abstract][Full Text] [Related]
3. Accuracy and feasibility of frameless stereotactic and robot-assisted CT-based puncture in interventional radiology: a comparative phantom study.
Stoffner R; Augschöll C; Widmann G; Böhler D; Bale R
Rofo; 2009 Sep; 181(9):851-8. PubMed ID: 19517342
[TBL] [Abstract][Full Text] [Related]
4. Use of the NeuroMate stereotactic robot in a frameless mode for functional neurosurgery.
Varma TR; Eldridge P
Int J Med Robot; 2006 Jun; 2(2):107-13. PubMed ID: 17520621
[TBL] [Abstract][Full Text] [Related]
5. Robotic neurological surgery applications: accuracy and consistency or pure fantasy?
Eljamel MS
Stereotact Funct Neurosurg; 2009; 87(2):88-93. PubMed ID: 19223694
[TBL] [Abstract][Full Text] [Related]
6. Frameless localization for functional neurosurgical procedures: a preliminary accuracy study.
Henderson JM
Stereotact Funct Neurosurg; 2004; 82(4):135-41. PubMed ID: 15467380
[TBL] [Abstract][Full Text] [Related]
7. Design and preliminary in vivo validation of a robotic laparoscope holder for minimally invasive surgery.
Herman B; Dehez B; Duy KT; Raucent B; Dombre E; Krut S
Int J Med Robot; 2009 Sep; 5(3):319-26. PubMed ID: 19455594
[TBL] [Abstract][Full Text] [Related]
8. A prototype biosensor-integrated image-guided surgery system.
Reisner LA; King BW; Klein MD; Auner GW; Pandya AK
Int J Med Robot; 2007 Mar; 3():82-8. PubMed ID: 17441030
[TBL] [Abstract][Full Text] [Related]
9. The application accuracy of a skull-mounted trajectory guide system for image-guided functional neurosurgery.
Henderson JM; Holloway KL; Gaede SE; Rosenow JM
Comput Aided Surg; 2004; 9(4):155-60. PubMed ID: 16192055
[TBL] [Abstract][Full Text] [Related]
10. Electromagnetic navigation improves minimally invasive robot-assisted lung brachytherapy.
Lin AW; Trejos AL; Mohan S; Bassan H; Kashigar A; Patel RV; Malthaner RA
Comput Aided Surg; 2008 Mar; 13(2):114-23. PubMed ID: 18317960
[TBL] [Abstract][Full Text] [Related]
11. A vision guided hybrid robotic prototype system for stereotactic surgery.
Wei J; Wang T; Liu D
Int J Med Robot; 2011 Dec; 7(4):475-81. PubMed ID: 21984231
[TBL] [Abstract][Full Text] [Related]
12. System for robotically assisted percutaneous procedures with computed tomography guidance.
Masamune K; Fichtinger G; Patriciu A; Susil RC; Taylor RH; Kavoussi LR; Anderson JH; Sakuma I; Dohi T; Stoianovici D
Comput Aided Surg; 2001; 6(6):370-83. PubMed ID: 11954068
[TBL] [Abstract][Full Text] [Related]
13. Robot-assisted minimally invasive lung brachytherapy.
Trejos AL; Lin AW; Pytel MP; Patel RV; Malthaner RA
Int J Med Robot; 2007 Mar; 3():41-51. PubMed ID: 17441025
[TBL] [Abstract][Full Text] [Related]
14. A new mechatronic assistance system for the neurosurgical operating theatre: implementation, assessment of accuracy and application concepts.
Rachinger J; Bumm K; Wurm J; Bohr C; Nissen U; Dannenmann T; Buchfelder M; Iro H; Nimsky C
Stereotact Funct Neurosurg; 2007; 85(5):249-55. PubMed ID: 17534138
[TBL] [Abstract][Full Text] [Related]
15. Robotics in neurosurgery.
McBeth PB; Louw DF; Rizun PR; Sutherland GR
Am J Surg; 2004 Oct; 188(4A Suppl):68S-75S. PubMed ID: 15476655
[TBL] [Abstract][Full Text] [Related]
16. A telerobotic haptic system for minimally invasive stereotactic neurosurgery.
Rossi A; Trevisani A; Zanotto V
Int J Med Robot; 2005 Jan; 1(2):64-75. PubMed ID: 17518380
[TBL] [Abstract][Full Text] [Related]
17. Adaptation of a hexapod-based robotic system for extended endoscope-assisted transsphenoidal skull base surgery.
Nimsky Ch; Rachinger J; Iro H; Fahlbusch R
Minim Invasive Neurosurg; 2004 Feb; 47(1):41-6. PubMed ID: 15100931
[TBL] [Abstract][Full Text] [Related]
18. Toward image guided robotic surgery: system validation.
Herrell SD; Kwartowitz DM; Milhoua PM; Galloway RL
J Urol; 2009 Feb; 181(2):783-9; discussion 789-90. PubMed ID: 19091336
[TBL] [Abstract][Full Text] [Related]
19. Evaluation of a neurosurgical robotic system to make accurate burr holes.
Brodie J; Eljamel S
Int J Med Robot; 2011 Mar; 7(1):101-6. PubMed ID: 21341368
[TBL] [Abstract][Full Text] [Related]
20. VarioGuide: a new frameless image-guided stereotactic system--accuracy study and clinical assessment.
Ringel F; Ingerl D; Ott S; Meyer B
Neurosurgery; 2009 May; 64(5 Suppl 2):365-71; discussion 371-3. PubMed ID: 19404116
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]