1427 related articles for article (PubMed ID: 17916377)
1. Comparison of gonioscopy and anterior segment ocular coherence tomography in detecting angle closure in different quadrants of the anterior chamber angle.
Sakata LM; Lavanya R; Friedman DS; Aung HT; Gao H; Kumar RS; Foster PJ; Aung T
Ophthalmology; 2008 May; 115(5):769-74. PubMed ID: 17916377
[TBL] [Abstract][Full Text] [Related]
2. Detection of primary angle closure using anterior segment optical coherence tomography in Asian eyes.
Nolan WP; See JL; Chew PT; Friedman DS; Smith SD; Radhakrishnan S; Zheng C; Foster PJ; Aung T
Ophthalmology; 2007 Jan; 114(1):33-9. PubMed ID: 17070597
[TBL] [Abstract][Full Text] [Related]
3. Evaluation of scanning protocols for imaging the anterior chamber angle with anterior segment-optical coherence tomography.
Khor WB; Sakata LM; Friedman DS; Narayanaswamy A; Lavanya R; Perera SA; Aung T
J Glaucoma; 2010 Aug; 19(6):365-8. PubMed ID: 19855287
[TBL] [Abstract][Full Text] [Related]
4. Relationship between intraocular pressure and angle configuration: an anterior segment OCT study.
Chong RS; Sakata LM; Narayanaswamy AK; Ho SW; He M; Baskaran M; Wong TY; Perera SA; Aung T
Invest Ophthalmol Vis Sci; 2013 Mar; 54(3):1650-5. PubMed ID: 23299476
[TBL] [Abstract][Full Text] [Related]
5. Degree of angle closure and extent of peripheral anterior synechiae: an anterior segment OCT study.
Su DH; Friedman DS; See JL; Chew PT; Chan YH; Nolan WP; Smith SD; Huang D; Zheng C; Li Y; Foster PJ; Aung T
Br J Ophthalmol; 2008 Jan; 92(1):103-7. PubMed ID: 17584995
[TBL] [Abstract][Full Text] [Related]
6. Quantitative iris parameters and association with narrow angles.
Wang B; Sakata LM; Friedman DS; Chan YH; He M; Lavanya R; Wong TY; Aung T
Ophthalmology; 2010 Jan; 117(1):11-7. PubMed ID: 19815290
[TBL] [Abstract][Full Text] [Related]
7. Comparison of EyeCam and anterior segment optical coherence tomography in detecting angle closure.
Baskaran M; Aung T; Friedman DS; Tun TA; Perera SA
Acta Ophthalmol; 2012 Dec; 90(8):e621-5. PubMed ID: 22938754
[TBL] [Abstract][Full Text] [Related]
8. Gonioscopy in adult Chinese: the Liwan Eye Study.
He M; Foster PJ; Ge J; Huang W; Wang D; Friedman DS; Khaw PT
Invest Ophthalmol Vis Sci; 2006 Nov; 47(11):4772-9. PubMed ID: 17065487
[TBL] [Abstract][Full Text] [Related]
9. Comparison of slitlamp optical coherence tomography and scanning peripheral anterior chamber depth analyzer to evaluate angle closure in Asian eyes.
Wong HT; Chua JL; Sakata LM; Wong MH; Aung HT; Aung T
Arch Ophthalmol; 2009 May; 127(5):599-603. PubMed ID: 19433707
[TBL] [Abstract][Full Text] [Related]
10. Imaging of the iridocorneal angle with the RTVue spectral domain optical coherence tomography.
Perera SA; Ho CL; Aung T; Baskaran M; Ho H; Tun TA; Lee TL; Kumar RS
Invest Ophthalmol Vis Sci; 2012 Apr; 53(4):1710-3. PubMed ID: 22395882
[TBL] [Abstract][Full Text] [Related]
11. Comparison of two spectral domain optical coherence tomography devices for angle-closure assessment.
Quek DT; Narayanaswamy AK; Tun TA; Htoon HM; Baskaran M; Perera SA; Aung T
Invest Ophthalmol Vis Sci; 2012 Aug; 53(9):5131-6. PubMed ID: 22786910
[TBL] [Abstract][Full Text] [Related]
12. Evaluation of the Anterior Segment Angle-to-Angle Scan of Cirrus High-Definition Optical Coherence Tomography and Comparison With Gonioscopy and With the Visante OCT.
Tun TA; Baskaran M; Tan SS; Perera SA; Aung T; Husain R
Invest Ophthalmol Vis Sci; 2017 Jan; 58(1):59-64. PubMed ID: 28061511
[TBL] [Abstract][Full Text] [Related]
13. Modified dark room provocative test for primary angle closure.
Li D; Wang N; Wang B; Wang T; Jonas JB
J Glaucoma; 2012 Mar; 21(3):155-9. PubMed ID: 21336147
[TBL] [Abstract][Full Text] [Related]
14. "Optical," not "ocular," coherence tomography.
Huang D
Ophthalmology; 2008 Nov; 115(11):2095-6. PubMed ID: 19068377
[No Abstract] [Full Text] [Related]
15. Assessment of circumferential angle-closure by the iris-trabecular contact index with swept-source optical coherence tomography.
Baskaran M; Ho SW; Tun TA; How AC; Perera SA; Friedman DS; Aung T
Ophthalmology; 2013 Nov; 120(11):2226-31. PubMed ID: 23774103
[TBL] [Abstract][Full Text] [Related]
16. Demonstration of angle widening using EyeCam after laser peripheral iridotomy in eyes with angle closure.
Perera SA; Quek DT; Baskaran M; Tun TA; Kumar RS; Friedman DS; Aung T
Am J Ophthalmol; 2010 Jun; 149(6):903-7. PubMed ID: 20417499
[TBL] [Abstract][Full Text] [Related]
17. Use of EyeCam for imaging the anterior chamber angle.
Perera SA; Baskaran M; Friedman DS; Tun TA; Htoon HM; Kumar RS; Aung T
Invest Ophthalmol Vis Sci; 2010 Jun; 51(6):2993-7. PubMed ID: 20071670
[TBL] [Abstract][Full Text] [Related]
18. Visualization of anterior chamber angle dynamics using optical coherence tomography.
Leung CK; Chan WM; Ko CY; Chui SI; Woo J; Tsang MK; Tse RK
Ophthalmology; 2005 Jun; 112(6):980-4. PubMed ID: 15936438
[TBL] [Abstract][Full Text] [Related]
19. Assessment of the scleral spur in anterior segment optical coherence tomography images.
Sakata LM; Lavanya R; Friedman DS; Aung HT; Seah SK; Foster PJ; Aung T
Arch Ophthalmol; 2008 Feb; 126(2):181-5. PubMed ID: 18268207
[TBL] [Abstract][Full Text] [Related]
20. Ocular biometry in the subtypes of angle closure: an anterior segment optical coherence tomography study.
Moghimi S; Vahedian Z; Fakhraie G; Ghaffari R; Eslami Y; Jabarvand M; Zarei R; Mohammadi M; Lin S
Am J Ophthalmol; 2013 Apr; 155(4):664-673, 673.e1. PubMed ID: 23246271
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]