BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

288 related articles for article (PubMed ID: 17920173)

  • 21. Investigation of locking configurations for tendon repair.
    Xie RG; Tang JB
    J Hand Surg Am; 2005 May; 30(3):461-5. PubMed ID: 15925152
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Optimizing biomechanical performance of the 4-strand cruciate flexor tendon repair.
    Dona E; Gianoutsos MP; Walsh WR
    J Hand Surg Am; 2004 Jul; 29(4):571-80. PubMed ID: 15249078
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A biomechanical comparison of 3 loop suture materials in a 6-strand flexor tendon repair technique.
    Gan AW; Neo PY; He M; Yam AK; Chong AK; Tay SC
    J Hand Surg Am; 2012 Sep; 37(9):1830-4. PubMed ID: 22857910
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Core suture purchase affects strength of tendon repairs.
    Tang JB; Zhang Y; Cao Y; Xie RG
    J Hand Surg Am; 2005 Nov; 30(6):1262-6. PubMed ID: 16344186
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Comparative biomechanic performances of locked cruciate four-strand flexor tendon repairs in an ex vivo porcine model.
    Croog A; Goldstein R; Nasser P; Lee SK
    J Hand Surg Am; 2007 Feb; 32(2):225-32. PubMed ID: 17275598
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Cyclic testing of pullout sutures and micro-mitek suture anchors in flexor digitorum profundus tendon distal fixation.
    Latendresse K; Dona E; Scougall PJ; Schreuder FB; Puchert E; Walsh WR
    J Hand Surg Am; 2005 May; 30(3):471-8. PubMed ID: 15925154
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Biomechanical assessment of a new type of flexor tendon repair.
    Smith AM; Evans DM
    J Hand Surg Br; 2001 Jun; 26(3):217-9. PubMed ID: 11386770
    [TBL] [Abstract][Full Text] [Related]  

  • 28. The impact of fiberwire, fiberloop, and locking suture configuration on flexor tendon repairs.
    Haimovici L; Papafragkou S; Lee W; Dagum A; Hurst LC
    Ann Plast Surg; 2012 Oct; 69(4):468-70. PubMed ID: 22964669
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Optimum suture material for locking technique in tendon repair: effects of suture friction in mobilization.
    Yamagami N; Mori R; Yotsumoto T; Hatanaka H; Uchio Y
    Clin Biomech (Bristol, Avon); 2011 Jun; 26(5):529-34. PubMed ID: 21342739
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Tendon repair with the strengthened modified Kessler, modified Kessler, and Savage suture techniques: a biomechanical comparison].
    Pişkin A; Yücetürk A; Tomak Y; Ozer M; Gülman B; Ataman A; Kangal M; Sahin Y; Desteli E; Aliç T
    Acta Orthop Traumatol Turc; 2007; 41(3):238-43. PubMed ID: 17876126
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A biomechanical comparison of a tendon repair device and 4 stranded, cruciate repair sutures for flexor tendon ruptured.
    Tantadprasert S; Jeeravipoolvarn P; Kosuwon W; Chaiyasivamongkon K
    J Med Assoc Thai; 2009 Nov; 92(11):1434-41. PubMed ID: 19938734
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Flexor tendon repairs: the impact of fiberwire on grasping and locking core sutures.
    Miller B; Dodds SD; deMars A; Zagoreas N; Waitayawinyu T; Trumble TE
    J Hand Surg Am; 2007; 32(5):591-6. PubMed ID: 17481994
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Comparison of postoperative early active mobilization and immobilization in vivo utilising a four-strand flexor tendon repair.
    Wada A; Kubota H; Miyanishi K; Hatanaka H; Miura H; Iwamoto Y
    J Hand Surg Br; 2001 Aug; 26(4):301-6. PubMed ID: 11469830
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Comparison of a suture technique with the modified Kessler method: resistance to gap formation.
    Barmakian JT; Lin H; Green SM; Posner MA; Casar RS
    J Hand Surg Am; 1994 Sep; 19(5):777-81. PubMed ID: 7806799
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A biomechanical analysis of the modified Tsuge suture technique for repair of flexor tendon lacerations.
    Labana N; Messer T; Lautenschlager E; Nagda S; Nagle D
    J Hand Surg Br; 2001 Aug; 26(4):297-300. PubMed ID: 11469829
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Biomechanical assessment of suture techniques used for tendon repair.
    Yalçin L; Demirci MS; Alp M; Akkin SM; Sener B; Koebke J
    Acta Orthop Traumatol Turc; 2011; 45(6):453-7. PubMed ID: 22245823
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The optimum length of the Silfverskiöld circumferential cross stitch.
    Hirpara KM; Sullivan PJ; O'Neill B; O'Sullivan M
    J Hand Surg Eur Vol; 2009 Oct; 34(5):651-5. PubMed ID: 19959448
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A new core suture technique for flexor tendon repair: biomechanical analysis of tensile strength and gap formation.
    Aslam A; Afoke A
    J Hand Surg Br; 2000 Aug; 25(4):390-2. PubMed ID: 11058011
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Strength enhancement of the interlocking mechanism in cross-stitch peripheral sutures for flexor tendon repair: biomechanical comparisons by cyclic loading.
    Takeuchi N; Mitsuyasu H; Hotokezaka S; Miura H; Higaki H; Iwamoto Y
    J Hand Surg Eur Vol; 2010 Jan; 35(1):46-50. PubMed ID: 19786410
    [TBL] [Abstract][Full Text] [Related]  

  • 40. An in vivo study of locking and grasping techniques using a passive mobilization protocol in experimental animals.
    Hatanaka H; Zhang J; Manske PR
    J Hand Surg Am; 2000 Mar; 25(2):260-9. PubMed ID: 10722817
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 15.