273 related articles for article (PubMed ID: 17926583)
1. Monitoring tracheal tube cuff pressures in the intensive care unit: a comparison of digital palpation and manometry.
Morris LG; Zoumalan RA; Roccaforte JD; Amin MR
Ann Otol Rhinol Laryngol; 2007 Sep; 116(9):639-42. PubMed ID: 17926583
[TBL] [Abstract][Full Text] [Related]
2. Estimation of tracheostomy tube cuff pressure by pilot balloon palpation.
Faris C; Koury E; Philpott J; Sharma S; Tolley N; Narula A
J Laryngol Otol; 2007 Sep; 121(9):869-71. PubMed ID: 17210092
[TBL] [Abstract][Full Text] [Related]
3. Endotracheal tube cuff pressures in pediatric patients intubated before aeromedical transport.
Tollefsen WW; Chapman J; Frakes M; Gallagher M; Shear M; Thomas SH
Pediatr Emerg Care; 2010 May; 26(5):361-3. PubMed ID: 20404779
[TBL] [Abstract][Full Text] [Related]
4. Effects of Increasing Airway Pressures on the Pressure of the Endotracheal Tube Cuff During Pelvic Laparoscopic Surgery.
Rosero EB; Ozayar E; Eslava-Schmalbach J; Minhajuddin A; Joshi GP
Anesth Analg; 2018 Jul; 127(1):120-125. PubMed ID: 29189283
[TBL] [Abstract][Full Text] [Related]
5. A comparison of endotracheal tube cuff pressures using estimation techniques and direct intracuff measurement.
Stewart SL; Secrest JA; Norwood BR; Zachary R
AANA J; 2003 Dec; 71(6):443-7. PubMed ID: 15098531
[TBL] [Abstract][Full Text] [Related]
6. Prospective observational study on tracheal tube cuff pressures in emergency patients--is neglecting the problem the problem?
Harm F; Zuercher M; Bassi M; Ummenhofer W
Scand J Trauma Resusc Emerg Med; 2013 Dec; 21():83. PubMed ID: 24304522
[TBL] [Abstract][Full Text] [Related]
7. Endotracheal tube cuff pressure assessment: pitfalls of finger estimation and need for objective measurement.
Fernandez R; Blanch L; Mancebo J; Bonsoms N; Artigas A
Crit Care Med; 1990 Dec; 18(12):1423-6. PubMed ID: 2245619
[TBL] [Abstract][Full Text] [Related]
8. Measuring tracheal tube cuff pressures--tool and technique.
Bouvier JR
Heart Lung; 1981; 10(4):686-90. PubMed ID: 6909196
[TBL] [Abstract][Full Text] [Related]
9. An in vitro study to assess determinant features associated with fluid sealing in the design of endotracheal tube cuffs and exerted tracheal pressures.
Li Bassi G; Ranzani OT; Marti JD; Giunta V; Luque N; Isetta V; Ferrer M; Farre R; Pimentel GL; Torres A
Crit Care Med; 2013 Feb; 41(2):518-26. PubMed ID: 23263575
[TBL] [Abstract][Full Text] [Related]
10. Anesthesia apparatus: Cuff Mate-2, endotracheal cuff inflator and pressure monitor.
Swaiss I; Badran I
Middle East J Anaesthesiol; 2003 Jun; 17(2):311-8. PubMed ID: 14503132
[TBL] [Abstract][Full Text] [Related]
11. Endotracheal tube cuff pressures - the worrying reality: a comparative audit of intra-operative versus emergency intubations.
Bernon JK; McGuire CI; Carrara H; Lubbe DE
S Afr Med J; 2013 Jun; 103(9):641-3. PubMed ID: 24300683
[TBL] [Abstract][Full Text] [Related]
12. Rapid pressure compensation by automated cuff pressure controllers worsens sealing in tracheal tubes.
Weiss M; Doell C; Koepfer N; Madjdpour C; Woitzek K; Bernet V
Br J Anaesth; 2009 Feb; 102(2):273-8. PubMed ID: 19112060
[TBL] [Abstract][Full Text] [Related]
13. Evaluation of the endotracheal tube cuff pressure resulting from four different methods of inflation in dogs.
Briganti A; Portela DA; Barsotti G; Romano M; Breghi G
Vet Anaesth Analg; 2012 Sep; 39(5):488-94. PubMed ID: 22642369
[TBL] [Abstract][Full Text] [Related]
14. Prevalence and predictors of out-of-range cuff pressure of endotracheal and tracheostomy tubes: a prospective cohort study in mechanically ventilated patients.
Alzahrani AR; Al Abbasi S; Abahoussin OK; Al Shehri TO; Al-Dorzi HM; Tamim HM; Sadat M; Arabi YM
BMC Anesthesiol; 2015 Oct; 15():147. PubMed ID: 26471790
[TBL] [Abstract][Full Text] [Related]
15. [Continuous monitoring of endotracheal tube cuff pressure: best practice in intensive care unit].
Danielis M; Benatti S; Celotti P; De Monte A; Trombini O
Assist Inferm Ric; 2015; 34(1):15-20. PubMed ID: 25837331
[TBL] [Abstract][Full Text] [Related]
16. Endotracheal tube cuff pressure: need for precise measurement.
Braz JR; Navarro LH; Takata IH; Nascimento Júnior P
Sao Paulo Med J; 1999 Nov; 117(6):243-7. PubMed ID: 10625887
[TBL] [Abstract][Full Text] [Related]
17. Intracuff pressures of endotracheal tubes in the management of airway emergencies: the need for pressure monitoring.
Galinski M; Tréoux V; Garrigue B; Lapostolle F; Borron SW; Adnet F
Ann Emerg Med; 2006 Jun; 47(6):545-7. PubMed ID: 16713783
[TBL] [Abstract][Full Text] [Related]
18. Modification of Tracheal Cuff Shape and Continuous Cuff Pressure Control to Prevent Microaspiration in an Ex Vivo Pig Tracheal Two-Lung Model.
Monsel A; Le Corre M; Deransy R; Brisson H; Arbelot C; Lu Q; Golmard JL; Langeron O; Rouby JJ
Crit Care Med; 2017 Dec; 45(12):e1262-e1269. PubMed ID: 29019852
[TBL] [Abstract][Full Text] [Related]
19. Use and care of an endotracheal/tracheostomy tube cuff--are intensive care unit staff adequately informed?
Mol DA; De Villiers Gdu T; Claassen AJ; Joubert G
S Afr J Surg; 2004 Feb; 42(1):14-6. PubMed ID: 15181709
[TBL] [Abstract][Full Text] [Related]
20. Technical communication: design and in vitro testing of a pressure-sensing syringe for endotracheal tube cuffs.
Slocum AH; Slocum AH; Spiegel JE
Anesth Analg; 2012 May; 114(5):967-71. PubMed ID: 22492187
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]