161 related articles for article (PubMed ID: 17929070)
1. Wireless and inductively powered implant for measuring electrocardiogram.
Riistama J; Väisänen J; Heinisuo S; Harjunpää H; Arra S; Kokko K; Mäntylä M; Kaihilahti J; Heino P; Kellomäki M; Vainio O; Vanhala J; Lekkala J; Hyttinen J
Med Biol Eng Comput; 2007 Dec; 45(12):1163-74. PubMed ID: 17929070
[TBL] [Abstract][Full Text] [Related]
2. Evaluation of an implantable ECG monitoring device in vitro and in vivo.
Riistama J; Väisänen J; Heinisuo S; Lekkala J; Kaihilahti J
Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():5704-7. PubMed ID: 18003307
[TBL] [Abstract][Full Text] [Related]
3. Wireless powering and data telemetry for biomedical implants.
Young DJ
Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():3221-4. PubMed ID: 19964060
[TBL] [Abstract][Full Text] [Related]
4. Miniature wireless measurement node for ECG signal transmission in home area network.
Vehkaoja AT; Verho JA; Lekkala JO
Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():2049-52. PubMed ID: 17946932
[TBL] [Abstract][Full Text] [Related]
5. Miniaturization of implantable wireless power receiver.
Poon AS
Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():3217-20. PubMed ID: 19964059
[TBL] [Abstract][Full Text] [Related]
6. Low power IC design of the Wireless Monitoring System of the Orthopedic Implants.
Chen H; Liu M; Jia C; Zhang C; Wang Z
Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():5767-70. PubMed ID: 18003323
[TBL] [Abstract][Full Text] [Related]
7. A complete data and power telemetry system utilizing BPSK and LSK signaling for biomedical implants.
Sonkusale S; Luo Z
Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():3216-9. PubMed ID: 19163391
[TBL] [Abstract][Full Text] [Related]
8. A dual band wireless power and data telemetry for retinal prosthesis.
Wang G; Liu W; Sivaprakasam M; Zhou M; Weiland JD; Humayun MS
Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():4392-5. PubMed ID: 17946243
[TBL] [Abstract][Full Text] [Related]
9. A portable, low-cost, battery-powered wireless monitoring system for obtaining varying physiologic parameters from multiple subjects.
Zhao H; Chen X; Chon KH
Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():5896-9. PubMed ID: 17946725
[TBL] [Abstract][Full Text] [Related]
10. A dual band wireless power and FSK data telemetry for biomedical implants.
Jung LH; Byrnes-Preston P; Hessler R; Lehmann T; Suaning GJ; Lovell NH
Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():6597-600. PubMed ID: 18003537
[TBL] [Abstract][Full Text] [Related]
11. Implantable physiologic controller for left ventricular assist devices with telemetry capability.
Asgari SS; Bonde P
J Thorac Cardiovasc Surg; 2014 Jan; 147(1):192-202. PubMed ID: 24176267
[TBL] [Abstract][Full Text] [Related]
12. The study and design of a wireless ECG monitoring system.
Yang H; Chai J
Biomed Instrum Technol; 2012; 46(5):395-9. PubMed ID: 23039742
[TBL] [Abstract][Full Text] [Related]
13. Novel technology for the provision of power to implantable physiological devices.
Budgett DM; Hu AP; Si P; Pallas WT; Donnelly MG; Broad JW; Barrett CJ; Guild SJ; Malpas SC
J Appl Physiol (1985); 2007 Apr; 102(4):1658-63. PubMed ID: 17218431
[TBL] [Abstract][Full Text] [Related]
14. Laser Driven Miniature Diamond Implant for Wireless Retinal Prostheses.
Ahnood A; Cheriton R; Bruneau A; Belcourt JA; Ndabakuranye JP; Lemaire W; Hilkes R; Fontaine R; Cook JPD; Hinzer K; Prawer S
Adv Biosyst; 2020 Nov; 4(11):e2000055. PubMed ID: 33084251
[TBL] [Abstract][Full Text] [Related]
15. A closed-loop inductive power control system for an instrumented strain sensing tibial implant.
Shiying Hao ; Taylor S
Annu Int Conf IEEE Eng Med Biol Soc; 2014; 2014():6553-6. PubMed ID: 25571497
[TBL] [Abstract][Full Text] [Related]
16. Simulative and experimental research on wireless power transmission technique in implantable medical device.
Yu Y; Hao H; Wang W; Li L
Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():923-6. PubMed ID: 19963736
[TBL] [Abstract][Full Text] [Related]
17. [Wireless ECG measurement system with capacitive coupling].
Aleksandrowicz A; Walter M; Leonhardt S
Biomed Tech (Berl); 2007 Apr; 52(2):185-92. PubMed ID: 17408378
[TBL] [Abstract][Full Text] [Related]
18. Transmission power requirements for novel ZigBee implants in the gastrointestinal tract.
Valdastri P; Menciassi A; Dario P
IEEE Trans Biomed Eng; 2008 Jun; 55(6):1705-10. PubMed ID: 18714834
[TBL] [Abstract][Full Text] [Related]
19. Wireless energy transfer platform for medical sensors and implantable devices.
Zhang F; Hackworth SA; Liu X; Chen H; Sclabassi RJ; Sun M
Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():1045-8. PubMed ID: 19964948
[TBL] [Abstract][Full Text] [Related]
20. Development of a miniaturised drug delivery system with wireless power transfer and communication.
Smith S; Tang TB; Terry JG; Stevenson JT; Flynn BW; Reekie HM; Murray AF; Gundlach AM; Renshaw D; Dhillon B; Ohtori A; Inoue Y; Walton AJ
IET Nanobiotechnol; 2007 Oct; 1(5):80-6. PubMed ID: 17764377
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]