BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

181 related articles for article (PubMed ID: 17933206)

  • 1. Leak testing in parenteral packaging: establishment of direct correlation between helium leak rate measurements and microbial ingress for two different leak types.
    Morrical BD; Goverde M; Grausse J; Gerwig T; Vorgrimler L; Morgen R; Büttiker JP
    PDA J Pharm Sci Technol; 2007; 61(4):226-36. PubMed ID: 17933206
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Pharmaceutical container/closure integrity. II: The relationship between microbial ingress and helium leak rates in rubber-stoppered glass vials.
    Kirsch LE; Nguyen L; Moeckly CS; Gerth R
    PDA J Pharm Sci Technol; 1997; 51(5):195-202. PubMed ID: 9357305
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Artificial Leaks in Container Closure Integrity Testing: Nonlinear Finite Element Simulation of Aperture Size Originated by a Copper Wire Sandwiched between the Stopper and the Glass Vial.
    Nieto A; Roehl H; Brown H; Adler M; Chalus P; Mahler HC
    PDA J Pharm Sci Technol; 2016; 70(4):313-24. PubMed ID: 27020649
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparing Physical Container Closure Integrity Test Methods and Artificial Leak Methodologies.
    Peláez SS; Mahler HC; Herdlitschka C; Wertli T; Kahl M; Koulov A; Matter A; Singh SK; Widmer M; Germershaus O; Mathaes R
    PDA J Pharm Sci Technol; 2019; 73(3):220-234. PubMed ID: 30651337
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Method Development for Container Closure Integrity Evaluation via Headspace Gas Ingress by Using Frequency Modulation Spectroscopy.
    Victor KG; Levac L; Timmins M; Veale J
    PDA J Pharm Sci Technol; 2017; 71(6):429-453. PubMed ID: 28733333
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Pharmaceutical container/closure integrity. III: Validation of the helium leak rate method for rigid pharmaceutical containers.
    Kirsch LE; Nguyen L; Gerth R
    PDA J Pharm Sci Technol; 1997; 51(5):203-7. PubMed ID: 9357306
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Pharmaceutical container/closure integrity. I: Mass spectrometry-based helium leak rate detection for rubber-stoppered glass vials.
    Kirsch LE; Nguyen L; Moeckly CS
    PDA J Pharm Sci Technol; 1997; 51(5):187-94. PubMed ID: 9357304
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pharmaceutical container/closure integrity. IV: Development of an indirect correlation between vacuum decay leak measurement and microbial ingress.
    Nguyen LT; Muangsiri W; Schiere R; Guazzo DK; Kirsch LE
    PDA J Pharm Sci Technol; 1999; 53(4):211-6. PubMed ID: 10754714
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Helium leak testing of packages for oral drug products.
    Kossinna J; Meyer A
    Eur J Pharm Biopharm; 2010 Jun; 75(2):297-303. PubMed ID: 20227495
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Quantifying the Vial Capping Process: Residual Seal Force and Container Closure Integrity.
    Ovadia R; Streubel A; Webb-Vargas Y; Ulland L; Luemkemann J; Rauch K; Eder J; Lam P; Tegoulia V; Maa YF
    PDA J Pharm Sci Technol; 2019; 73(1):2-15. PubMed ID: 29954924
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Balancing Container Closure Integrity and Aesthetics for a Robust Aseptic or Sterile Vial Packaging System.
    Oni Y; Song X; Schrader M; Kulshrestha A; Franck J; Asselta R; Flores-Crespo C; Mantri RV
    PDA J Pharm Sci Technol; 2019; 73(6):572-587. PubMed ID: 31101708
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Pharmaceutical container/closure integrity. V: An evaluation of the WILCO "LFC" method for leak testing pharmaceutical glass-stoppered vials.
    Kirsch LE; Nguyen L; Kirsch AM; Schmitt G; Koch M; Wertli T; Lehmann M; Schramm G
    PDA J Pharm Sci Technol; 1999; 53(5):235-9. PubMed ID: 10754718
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Vacuum decay container/closure integrity testing technology. Part 2. Comparison to dye ingress tests.
    Wolf H; Stauffer T; Chen SC; Lee Y; Forster R; Ludzinski M; Kamat M; Mulhall B; Guazzo DM
    PDA J Pharm Sci Technol; 2009; 63(5):489-98. PubMed ID: 20158053
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Non-destructive vacuum decay method for pre-filled syringe closure integrity testing compared with dye ingress testing and high-voltage leak detection.
    Simonetti A; Amari F
    PDA J Pharm Sci Technol; 2015; 69(1):108-22. PubMed ID: 25691719
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Vacuum decay container/closure integrity testing technology. Part 1. ASTM F2338-09 precision and bias studies.
    Wolf H; Stauffer T; Chen SC; Lee Y; Forster R; Ludzinski M; Kamat M; Godorov P; Guazzo DM
    PDA J Pharm Sci Technol; 2009; 63(5):472-88. PubMed ID: 20158052
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Pharmaceutical container/closure integrity. VI: A report on the utility of liquid tracer methods for evaluating the microbial barrier properties of pharmaceutical packaging.
    Kirsch LE
    PDA J Pharm Sci Technol; 2000; 54(4):305-14. PubMed ID: 10969527
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Container Closure Integrity Testing-Practical Aspects and Approaches in the Pharmaceutical Industry.
    Brown H; Mahler HC; Mellman J; Nieto A; Wagner D; Schaar M; Mathaes R; Kossinna J; Schmitting F; Dreher S; Roehl H; Hemminger M; Wuchner K
    PDA J Pharm Sci Technol; 2017; 71(2):147-162. PubMed ID: 27789803
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Development of a dye ingress method to assess container-closure integrity: correlation to microbial ingress.
    Burrell LS; Carver MW; DeMuth GE; Lambert WJ
    PDA J Pharm Sci Technol; 2000; 54(6):449-55. PubMed ID: 11107837
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A Multicompany Survey Study for Helium Leak Container Closure Integrity Test.
    Mathaes R; Wuchner K; Riesop D; Wagner D; Dreher S; Woelfle F; Mudumala PR; Bonvin D; Müller C; Traub-Hoffmann K; Hebting H
    PDA J Pharm Sci Technol; 2022; 76(3):216-235. PubMed ID: 34782444
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Quantitative and mechanistic measurements of parenteral vial container/closure integrity. Leakage quantitation.
    Morton DK; Lordi NG; Ambrosio TJ
    J Parenter Sci Technol; 1989; 43(2):88-97. PubMed ID: 2709241
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.