These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
128 related articles for article (PubMed ID: 1793553)
41. Simultaneous determination of tryptophan, uric acid and ascorbic acid at iron(III) doped zeolite modified carbon paste electrode. Babaei A; Zendehdel M; Khalilzadeh B; Taheri A Colloids Surf B Biointerfaces; 2008 Oct; 66(2):226-32. PubMed ID: 18703321 [TBL] [Abstract][Full Text] [Related]
42. DNA as a support for glucose oxidase immobilization at Prussian blue-modified glassy carbon electrode in biosensor preparation. Kafi AK; Lee DY; Park SH; Kwon YS J Nanosci Nanotechnol; 2006 Nov; 6(11):3539-42. PubMed ID: 17252806 [TBL] [Abstract][Full Text] [Related]
43. L-amino acid biosensor based on L-amino acid oxidase immobilized onto NiHCNFe/c-MWCNT/PPy/GC electrode. Lata S; Pundir CS Int J Biol Macromol; 2013 Mar; 54():250-7. PubMed ID: 23237796 [TBL] [Abstract][Full Text] [Related]
44. Immobilization of acetylcholineesterase-choline oxidase on a gold-platinum bimetallic nanoparticles modified glassy carbon electrode for the sensitive detection of organophosphate pesticides, carbamates and nerve agents. Upadhyay S; Rao GR; Sharma MK; Bhattacharya BK; Rao VK; Vijayaraghavan R Biosens Bioelectron; 2009 Dec; 25(4):832-8. PubMed ID: 19762223 [TBL] [Abstract][Full Text] [Related]
45. Amperometric acetylcholine sensor catalyzed by nickel anode electrode. Lin S; Liu CC; Chou TC Biosens Bioelectron; 2004 Jul; 20(1):9-14. PubMed ID: 15142571 [TBL] [Abstract][Full Text] [Related]
46. Amperometric l-ascorbic acid biosensors equipped with enzyme micelle membrane. Wang X; Watanabe H; Uchiyama S Talanta; 2008 Feb; 74(5):1681-5. PubMed ID: 18371836 [TBL] [Abstract][Full Text] [Related]
47. Amperometric determination of choline with enzyme immobilized in a hybrid mesoporous membrane. Shimomura T; Itoh T; Sumiya T; Mizukami F; Ono M Talanta; 2009 Apr; 78(1):217-20. PubMed ID: 19174228 [TBL] [Abstract][Full Text] [Related]
48. Multienzyme microbiosensor based on electropolymerized o-phenylenediamine for simultaneous in vitro determination of acetylcholine and choline. Khan A; Ab Ghani S Biosens Bioelectron; 2012 Jan; 31(1):433-8. PubMed ID: 22154168 [TBL] [Abstract][Full Text] [Related]
49. An amperometric acetylcholine biosensor based on a conducting polymer. Kanik FE; Kolb M; Timur S; Bahadir M; Toppare L Int J Biol Macromol; 2013 Aug; 59():111-8. PubMed ID: 23603072 [TBL] [Abstract][Full Text] [Related]
50. Amperometric L-lactate biosensor based on screen-printed carbon electrode containing cobalt phthalocyanine, coated with lactate oxidase-mesoporous silica conjugate layer. Shimomura T; Sumiya T; Ono M; Ito T; Hanaoka TA Anal Chim Acta; 2012 Feb; 714():114-20. PubMed ID: 22244144 [TBL] [Abstract][Full Text] [Related]
51. Development of a novel biosensor based on a polypyrrole-dodecylbenzene sulphonate (PPy-DBS) film for the determination of amperometric cholesterol. Özer BO; Çete S Artif Cells Nanomed Biotechnol; 2017 Jun; 45(4):824-832. PubMed ID: 27571602 [TBL] [Abstract][Full Text] [Related]
52. A new modified conducting carbon composite electrode as sensor for ascorbate and biosensor for glucose. Barsan MM; Brett CM Bioelectrochemistry; 2009 Sep; 76(1-2):135-40. PubMed ID: 19349215 [TBL] [Abstract][Full Text] [Related]
53. Enhanced measurement stability and selectivity for choline and acetylcholine by capillary electrophoresis with electrochemical detection at a covalently linked enzyme-modified electrode. Inoue T; Kirchhoff JR; Hudson RA Anal Chem; 2002 Oct; 74(20):5321-6. PubMed ID: 12403587 [TBL] [Abstract][Full Text] [Related]
54. A novel, disposable, screen-printed amperometric biosensor for ketone 3-β-hydroxybutyrate fabricated using a 3-β-hydroxybutyrate dehydrogenase-mesoporous silica conjugate. Shimomura T; Sumiya T; Ono M; Ito T; Hanaoka TA Anal Bioanal Chem; 2013 Jan; 405(1):297-305. PubMed ID: 23096941 [TBL] [Abstract][Full Text] [Related]
55. Amperometric microsensor for direct probing of ascorbic acid in human gastric juice. Hutton EA; Pauliukaitė R; Hocevar SB; Ogorevc B; Smyth MR Anal Chim Acta; 2010 Sep; 678(2):176-82. PubMed ID: 20888449 [TBL] [Abstract][Full Text] [Related]
56. Carbon paste electrode modified with copper (II) phosphate immobilized in a polyester resin for voltammetric determination of L-ascorbic acid in pharmaceutical formulations. Teixeira MF; Ramos LA; Fatibello-Filho O; Cavalheiro ET Anal Bioanal Chem; 2003 May; 376(2):214-9. PubMed ID: 12677341 [TBL] [Abstract][Full Text] [Related]
57. Determination of underivatized amino acids by high-performance liquid chromatography and electrochemical detection at an amino acid oxidase immobilized CuPtCI6 modified electrode. Pei J; Li X Fresenius J Anal Chem; 2000 Aug; 367(8):707-13. PubMed ID: 11220604 [TBL] [Abstract][Full Text] [Related]
58. An enzyme electrode for amperometric measurement of D-amino acid. Wu X; Van Wie BJ; Kidwell DA Biosens Bioelectron; 2004 Nov; 20(4):879-86. PubMed ID: 15522605 [TBL] [Abstract][Full Text] [Related]
59. Amperometric detection of single vesicle acetylcholine release events from an artificial cell. Keighron JD; Wigström J; Kurczy ME; Bergman J; Wang Y; Cans AS ACS Chem Neurosci; 2015 Jan; 6(1):181-8. PubMed ID: 25565357 [TBL] [Abstract][Full Text] [Related]
60. Electrocatalytic microelectrode detectors for choline and acetylcholine following separation by capillary electrophoresis. Mukherjee J; Kirchhoff JR Anal Chem; 2009 Aug; 81(16):6996-7002. PubMed ID: 20337384 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]