1. On foundations of discrete element analysis of contact in diarthrodial joints. Volokh KY; Chao EY; Armand M Mol Cell Biomech; 2007 Jun; 4(2):67-73. PubMed ID: 17937111 [TBL] [Abstract][Full Text] [Related]
2. A new discrete element analysis method for predicting hip joint contact stresses. Abraham CL; Maas SA; Weiss JA; Ellis BJ; Peters CL; Anderson AE J Biomech; 2013 Apr; 46(6):1121-7. PubMed ID: 23453394 [TBL] [Abstract][Full Text] [Related]
3. Discrete element analysis in musculoskeletal biomechanics. Chao EY; Volokh KY; Yoshida H; Shiba N; Ide T Mol Cell Biomech; 2010 Sep; 7(3):175-92. PubMed ID: 21141680 [TBL] [Abstract][Full Text] [Related]
4. Evaluation of the finite element software ABAQUS for biomechanical modelling of biphasic tissues. Wu JZ; Herzog W; Epstein M J Biomech; 1998 Feb; 31(2):165-9. PubMed ID: 9593211 [TBL] [Abstract][Full Text] [Related]
5. A theoretical solution for the frictionless rolling contact of cylindrical biphasic articular cartilage layers. Ateshian GA; Wang H J Biomech; 1995 Nov; 28(11):1341-55. PubMed ID: 8522547 [TBL] [Abstract][Full Text] [Related]
6. Biphasic finite element modeling of hydrated soft tissue contact using an augmented Lagrangian method. Guo H; Spilker RL J Biomech Eng; 2011 Nov; 133(11):111001. PubMed ID: 22168733 [TBL] [Abstract][Full Text] [Related]
11. A finite element model of the human knee joint for the study of tibio-femoral contact. Donahue TL; Hull ML; Rashid MM; Jacobs CR J Biomech Eng; 2002 Jun; 124(3):273-80. PubMed ID: 12071261 [TBL] [Abstract][Full Text] [Related]
12. Elliptical contact of thin biphasic cartilage layers: exact solution for monotonic loading. Argatov I; Mishuris G J Biomech; 2011 Feb; 44(4):759-61. PubMed ID: 21093864 [TBL] [Abstract][Full Text] [Related]
13. Effects of inserting a pressensor film into articular joints on the actual contact mechanics. Wu JZ; Herzog W; Epstein M J Biomech Eng; 1998 Oct; 120(5):655-9. PubMed ID: 10412445 [TBL] [Abstract][Full Text] [Related]
14. Effect of bone inhomogeneity on tibiofemoral contact mechanics during physiological loading. Venäläinen MS; Mononen ME; Väänänen SP; Jurvelin JS; Töyräs J; Virén T; Korhonen RK J Biomech; 2016 May; 49(7):1111-1120. PubMed ID: 26965471 [TBL] [Abstract][Full Text] [Related]
15. An analytical model of joint contact. Eberhardt AW; Keer LM; Lewis JL; Vithoontien V J Biomech Eng; 1990 Nov; 112(4):407-13. PubMed ID: 2273867 [TBL] [Abstract][Full Text] [Related]
16. A finite element model of an idealized diarthrodial joint to investigate the effects of variation in the mechanical properties of the tissues. Dar FH; Aspden RM Proc Inst Mech Eng H; 2003; 217(5):341-8. PubMed ID: 14558646 [TBL] [Abstract][Full Text] [Related]
17. Effect of contact stress in bones of the distal interphalangeal joint on microscopic changes in articular cartilage and ligaments. Bowker RM; Atkinson PJ; Atkinson TS; Haut RC Am J Vet Res; 2001 Mar; 62(3):414-24. PubMed ID: 11277208 [TBL] [Abstract][Full Text] [Related]
18. A finite element implementation for biphasic contact of hydrated porous media under finite deformation and sliding. Guo H; Shah M; Spilker RL Proc Inst Mech Eng H; 2014 Mar; 228(3):225-36. PubMed ID: 24496915 [TBL] [Abstract][Full Text] [Related]
19. Load sharing between solid and fluid phases in articular cartilage: II--Comparison of experimental results and u-p finite element predictions. Mukherjee N; Wayne JS J Biomech Eng; 1998 Oct; 120(5):620-4. PubMed ID: 10412440 [TBL] [Abstract][Full Text] [Related]